Web Analytics Made Easy - StatCounter

Ultra Performance Liquid Chromatography Tenders

Get complete information related to latest Ultra Performance Liquid Chromatography Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ultra Performance Liquid Chromatography Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ultra Performance Liquid Chromatography Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45557734 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For corrigendum : 100276638_ 10_ m9406566001_ dc grouser earth fault locator

State Government

CTN :45658818 Due date: 14 Jul, 202614 Jul, 2026 10.36 Lacs
Tender For supply of d.c. earth fault locator (q2)

State Government

CTN :45263804 Due date: 01 Jul, 202601 Jul, 2026 4.63 Crore
Tender For corrigendum : tender for the supply of various equipments - muffle furnace, "al2o3 sample plate, al2o3 furnace door block, protection glove, crucible clip, crucibles, karl fischer titrator, "titration vessel, detector electrode with lead, generator electrode (with frit) with lead, desiccant tube and cap, injection septa (pack of 10), gas tight syringe 1.0ml , luer needle 17-gauge, dust cover, results manager software, main power pack, fuse, karl fischer titration reagent(s), nist calibration standard, refrigerated centrifuge (bench top), bottles/falcon tubes/adapters for 0.2ml tubes, one set of other items (adapters) required for improving the applicability/system performance should to be quoted, nitrogen evaporator, evaporation tubes, gas fuse , water purification system including water softner, cartridges, filters etc. for , bomb calorimeter, "ignition wire, cotton thread, combustion crucible, bomb, nist certified benzoic for calibration, any other accessories required for analysis of food samples., gas chromatograph with ecd, tcd, fid with autosampler, "pesticide column (30 m x 0.250mm x 0.25m (5ms (95% dimethyl-, 5% diphenyl-polysiloxane / 1ms (100% dimethyl polysiloxane or equivalent) 100 mm column for fatty acid profiling with main concern of trans fatty acid application, column for cholesterol application, stationary phase: 95% dimethyl-, 5% diphenyl-polysiloxane (30 m x 0.250mm x 0.25m),, "vial sets (1, 2 ml, crimp type, amber and clear glass), vials (10, 20ml crimp type with cap & septa), 300/500 l recovery vials, septa ptfe/silicone (for 1, 2 ml vials), septa ptfe/silicone (for 10, 20 ml headspace vials), ergonomic crimping tools for different vial types, ergonomic decapping tools for different vial types, head space vials 10,20 ml capacity, suitable syringes for quoted autosampler, suitable headspace syringe /valve/loop, quechers kits for pesticides and herbicides in following matrices:, matrices with high fat, matrices with high water content, matrices with high pigmented, spe cartridges for water., ultra performance liquid chromatography (uplc) with photodiode array (pda), fluorescence (fld) and refractive index detector (rid), sample vials with 1.5 ml or greater, stainless steel ultra sonic bath with the capacity of 5 l or more, with time setting (min) 1-30min or continuous operation with led and push button (should be ip 33 protection class) for sonication of spare parts as well as solvents, fittings, frits, ferules and tubings, tubing cutter, solvent bottles (1000 ml capacity), solvent filters (glass & ss both, compatible manual syringes -10 l, 20 l, 50 l, standards for hplc calibration for pda, ri and fluorescence detector, consumables required for each detector must be provided., "hplc columns: one each of, c8 = 250 4.6 5m c18 = 250 4.6 5m, cyano = 250 4.6 5m. amino = 250 4.6 5m, phenyl = 250 4.6 5m. silica = 250 4.6 5m., all columns must be supplied with respective guard column and holder. ", uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., uv-visible spectrophotometer, ",0.5, 1 and 3-ml quartz cuvettes 10 mm path length, 0.5, 1, and 3 ml glass cuvettes 10 mm path length, cuvette holder, suitable certified standards for validation including holmium oxide glass filters for wavelength calibration & nist traceable, nist traceable potassium dichromate., ft-ir with atr & liquid cell, " hydraulic press with kbr die and pellet holder, suitable mortar pestle (dia 5-6 cm), suitable portable de humidifier to maintain 30- 60% rh, temperature and relative humidity digital indicator with calibration certificate from iso 17025 accredited lab., reference nist standard polystyrene film (0.3 mm) over the range of 3800 cm-1 to 650 cm-1., abbes r

Central Government/Public Sector

CTN :45603567 Due date: 03 Jul, 202603 Jul, 2026 NA
Tender For supply of d.c. earth fault locator (q2)

Central Government/Public Sector

CTN :45549279 Due date: 17 Jun, 202617 Jun, 2026 NA
Tender For digital earth fault locator suitable for dc system voltage grades 220v,110v,48v & 24v working on dc power supply 220v & 110v or ac-220v external supply. the unit shall consist of the following items i.transmitter working on dc system voltage measurement range: 0v- 500v dc with measurement resolution dc 1v & accuracy of 5%+/-5v, system for ground impedance measurement range: 0-1m ,accuracy:10%+/-3k ii. a receiver with insulation resistance measuring range at least:0-600k , insulation impedance measurement resolution: 1k . & the resolution of earth leakage current detection: 0.1ma with built in rechargeable power supply. item to be supplied with suitable signal clamps, current sensors, power adapters. makes and model: metravi-dcgfl-999 or dc trace of scope t&m or equivalent. [ warranty period: 12 months after the date of delivery ] ]

State Government

CTN :44943510 Due date: 19 Jun, 202619 Jun, 2026 22.54 Crore
Tender For corrigendum : tender for the supply of various equipments required for upgradation of district food laborartory, karnal - bottle dispenser, deep freezer -20°, 400 l, deep freezer -40°c, capacity 400 l, abbe, refractometer, automated solid, phase extraction, system, electro magnetic, sieve shaker, solvent filtration, unit, automatic, glassware, washers and, dryers, rotary evaporator, with chiller, homogenizer, ultra sonic bath, digital butyro, refractometer, analytical balance, (0.0001 gram, (accuracy), hot air oven, polarimeter, ph meter, muffle furnace, vacuum oven, deep freezer -80°c, micro balance, refrigerator 700 l, (double door &, frost free), water purification, system, inductively coupled, plasma – mass, spectrometer (icpms), microwave digestor, gas chromatography, with tandem mass, spectrometry (gcmsms), lc-ms/ms, ics aquion - specs, ultra performance, liquid, chromatography, (uplc) with photo, diode array, (pda),fluorescence, (fld) and, refractive index, detector(rid)

CTN :45072925 Due date: 06 Jun, 202606 Jun, 2026 NA
Tender For corrigendum : supply of d.c. earth fault locator (q2)

Central Government/Public Sector

CTN :45098266 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For corrigendum : supply of procurement of dc earth fault locator

State Government

CTN :45014573 Due date: 28 May, 202628 May, 2026 10.36 Lacs
Tender For corrigendum : supply of d.c. earth fault locator (q2)

CTN :43978818 Due date: 15 May, 202615 May, 2026 NA
Tender For corrigendum : supply of dc earth fault locator
 Loading, Please wait...

Connect us via What's Up