Tender For electrical maintenace jobs at mughalsarai ird - routine electrical maintenance of depot , transformer oil testing , installation of acb spares , srvc f inspection and pm of acbs , servicing overhauling and testing f vcb , thermography testing of panel , sply instln lightning arrestor , earthing wire cu 6mm2 , sply and fixg of fuse element rating 11k , earthing clamp , calibration of meter , testing calibration of relay , repair of boom barrier , repair and maint of water pump , testing and servicing pv vent 3in , maint and insp tsvtest and re inst half yrly , sply of 33 kv rubber hand gloves isi app , 11kv rubber hand gloves , silica gel , distilled water battery litres , testing of transformer tan delta , rewinding of motor pump overhauling , electrical insulation mat 2 point 5 mm thick , pvc tape steel grip , crc spray cap 200ml , sply and instln of contactor rat 32a , elcb 30 ma 63 a legrand rating 415v 0 point 0 , elcb 32a 30ma dp w 2nosauxtrpcntct , mcb 415vac 32a 10ka 3p c iec60898 1 , mcb 415vac 63a 10ka 3p c iec60898 1 , hrc fuses for diodes 50a , sply and instln of contactor rat 70a , trip shunt coil acb 110vdc land t , braided wire cu 6mm2 , braided wire strip cu 1in , itc of lugs for 16 sqmm cu , lug ring cu 25mm2 , lamp led indctng 60w rd ylw bl hghmst cg , sup led driver 60w , racking mechanism up acb l and t upower , closing coil shnt trp 110vdc acb 800a , extl safety auditdepot terminal plant , sup and fix of crocodile cliphvydty f earth , contactor dc 110vdc 100a 3p btry chrgr , earthing strip size 50x60x6mm , testing of ht cable meggering and continuity , testing of lt cable meggering and continuity , partial disch testing of cable ht and lt , sply and instln of 2way flp jbtestg and comm , vlf testing of cable , earthing funnel gi , ss nut bolt 1 inch , sup and lay wbmstone aggregate 90 45mm , testing ir and motor tmnl conn yearly , preparation drawingloop diagram layout , autocad drawing retracinglayout conversi
Tender For repair/ replacement of internal water pipe line, insulation of water tank, puff tank and allied works in sector a under age b/r -ii of ge 865 ews
Tender For sh- repair of damaged boundary wall and replacement of broken/damaged g.i. sheet roofing with sandwich panel for insulation and other miscellaneous work
Tender For providing of repair and overhauling service - repair and overhauling; repair and overhauling; no; buyer premises - 02 nos check valve/nrvs are malfunctioning. same to be renewed as per sample and proved for satisfactory operation. , dd pump base frame/ trolley and exhaust damper deteriorated. same to be repaired/ renewed as per sample , 05 nos rotary hand pump from lub oil system to be overhauled and proved for satisfactory operation. all in way jobs included. , portable lub oil pump not getting suction. pump to be overhauled and proved for satisfactory operation. all in way jobs included. , pipe insulation, fitting insulation and valve insulation in ac system damaged & cracked due to ageing. same to be renewed as per sample.