Tender For repair rehabilitation and up gradation of disposal system including civil structure, rcc works, pumping machinery (30 hp motor pumps), di pipeline (k-9), ci specials, steel gates and const of rooms with washroom, installation of 82.5 kva diesel generator set at dh
Tender For providing, erecting, commissioning and giving satisfactory test and trial of 250 hp verticalturbinepumps and allied mechanical and electrical equipments for pumping raw water form jackwellat krishna ghat to water treatment plant at miraj
Tender For annual repair mo lwss berthin sergal bhaba kotla lop sunhani in tehsil jhandutta district bilaspur hp sh operation and maintenance of pumping machinery and distribution system of water supply from sector storage tanks to different habitations for one year
Tender For annual repair mo lwss tihra badgoun in tehsil jhandutta district bilaspur hp sh operation and maintenance of pumping machinery and distribution system of water supply from sector storage tanks to different habitations for one year
Tender For corrigendum : providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; electrical system or installation, biennial maintenance contract for 11kv siemens make vacuum circuit breakers (vcbs) in stp-2 plant/ghatkopar pumping sta..
Tender For dnit:- a/mtc. various water supply schemes under phe sub division no. 4, gurugram in rural area under phe division sohna. `comprehensive mtc. of distribution system, electromagnetical items i.e pumping machinery, panel board, cables of the existing t/wells etc, civil work including repair works, white wash, painting etc, disinfection and all other works contingent thereto for a period of 3 years`
Tender For corrigendum : repair and comprehensive maintenance of swimming pool plant and equipments fire fighting system at af stn nal under ge (af) nal - comprehensive annual maintenance of swimming pool comprises of the following equipments complete all as specified and directed.(a) pumping sets of capacity 3.5 hp - 05 nos (01 as standby) (b) pressure filter of filtering capacity 50 cum/hr - 04 nos (01 as standby)(c) dosing pump - 02 nos (one for chlorination and one for soda ash)(d) electrical panel board consisting of starters of suitable rating complete.note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit swimming pool once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of swimming pool.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account. (iii) cleaning all swimming pool building inside, plant room, equipments including surrounding area of the buildings. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of 3.5hp / 3.26 kw capacity and all other connected items., comprehensive annual maintenance of fire fighting system in sekhon hall , new tech flight, sre and new atc of the following equipments complete all as specified and directed.(a) main fire pump with centrifugal motor of existing capacity- 04 nos (b) jockey fire pump with electric motor of existing capacity - 04 nos (c) makeup fire pump- 04 nos(d) dg fire pump with engine - 04 nos note: rate quoted by the contractor shall deemed to be included for the following :-(i) contractor shall provide trained technician and a helper, who will visit fire fighting installation in sekhon hall , new tech flight and new atc once in a week, to check and servicing of the equipments above to ensure the serviceability and proper functioning of installation.(ii) grease and lubricating oil shall be provided by the contractor at his own end and nothing extra shall be payable on this account.(iii) cleaning all fire fighting installation buildings (sekhon hall , new tech flight and new atc) inside, plant room,equipments including surrounding area of the building. (iv) check serviceability of all self priming recirculation pump of single stage / horizontal self priming pump set of all existing capacity and all other connected items., s&f in repair pressure pump limit switch of capacity 1psi to 4 psi and 230 volt as per existing make and model fixed on pressure booster line complete all as specified and directed., supply, installation, testing and commissioning in repair of detectors complying with and type certified to en-45 addressable type multi sensor detector with heat and smoke combination with base with self built intelligence as per is:11360 (for annexes) complete all as specified and directed., supply, installation, testing and commissioning in repair of addressable manual call point / pill station resettable type with base complete all as specified and directed, supply, installation, testing and commissioning in repair of fire alarm sounder/siren electronic type horizontal single stage continuous type normal operation for atleast 50 minutes with sound level 65 db to 120 db measured at 1.5 mtr with sound output variation +5 db 500 mtr complete all as specified and directed, supply and fixing in repair addressable monitor module for activating the sirens complete all as specified and directed, taking out old unserviceable hose box by cutting and welding and s&f hose box made of 18 gauge ms sheet 800mmx 600 mm x 250 mm with double door with 4 mm thick glasses and door frame made of 16 gauge ms sheet for keeping 2 nos hose pipe of length 15 mtr each branch pipe nozzle coupling etc and painted fire red out side and brilliant white inside yard complete all as specified and dire
Tender For corrigendum : repair maintenance of external water supply along with connected works of pumping distribution system at zone i and ii area under ge dinjan
Tender For request for selection (rfs) document for selection of vendors for design, manufacture, supply, transport, installation, testing and commissioning of off-grid dc solar photovoltaic water pumping systems of 3 hp, 5 hp & 7.5 hp capacity at identified farmer s site in district of maharashtra, including complete system warranty and its repair and maintenance for 5 years under magel tyala saur krushi pump / pm kusum b scheme
Tender For e-quotation for seeking firm rates for non-schedule items for preparing estimates. - supplying , installation, testing and commissioning of verticalturbinepump set with ss impeller capable to discharge 126 m3/hr.against total head of 50 m, (make kirloskar/jyoti/wilo-mather&platt/wpil) coupled with suitable capacity vertical hollow shaft/solid shaft squirrel cage induction motor , rating of motor 20% more bhp than that of pump (make kirloskar /abb /cgl/ siemens) operated on 415 +/- 10% volt, 3 phase , 50 c/s a.c supply , ie3 type as per is:325 and iec:63400-ihaving speed 1450 rpm,with heavy duty m.s. column assembly with ss line shaft and each coloumn of 5 feet length including cost of supplying , fitting and fixing of all required accessories such as cidf sluice valve-1 set, cidf nr valve-1 set, pressure gauge-1 no, strainer-1 no, m.s. channel base plate etc. all complete including cost of taken out existing old pumpset., supplying and installation of fasd starter suitable for above mentioned vt pumpset make lk/bch/schneider., supplying and laying of 25 mm2 , 1.1 kv, 3 core pvc insulated unarmoured copper cable make polycab/kei/gloster, from starter to motor., supplying, installation testing and commissioning of horizontal split casing centrifugal pump set with bronze impeller having discharge 126 m3/hr. against total head of 35 m, (make - kirloskar/jyoti/wilo-mather&platt/wpil), coupled with suitable capacity squirrel cage induction motor, rating of motor 20% more bhp than that of pump(make kirloskar /abb /cgl/ siemens) ,tefc, ie3 type as per is:325 and iec:63400-ihaving speed 1450 rpm,operated on 415 +/- 10% volt, 3 phase , 50 c/s a.c supply, mounted on a commonm.s. base plate including cost of supplying , fitting and fixing of all required accessories such as cidf sluice valve-1 set, cidf nr valve-1 set, pressure gauge-1 no, foot valve-1no, etc. all complete including cost of taken out existing old pumpset., supplying and installation of fasd starter suitable for above mentioned c/f pumpset make lk/bch/schneider., supplying and laying of 16 mm2 , 1.1 kv, 3 core pvc insulated unarmoured copper cable make polycab/kei/gloster, from starter to motor., cost towards complete repairing of control panel at intake well with changing of damaged parts such as :-1.150 amp tpn mccb,50 ka -1 no. as incoming feeder.2. 75 amp tp mccb, 50 ka-2no as outgoing feeder.3.star delta timer-2nos(one for each starter) 4. 32 amp switch fuse unit -01 no. for internal and external light load.5. (0-500 v) volt meter-01 no., ampere meter-01 no.,three phase indicator lamp,powder coating paint,push button on/off,on/off/trip indicator lamp,wiring,etc as per required and testing on full load ., cost towards providing all labour, tools and technicians for taken out and dismantling 40 hp vt p/set with bowl assembly, 6" dia. coloumn pipe and line shaft etc all complete., cost towards dismantling and repairing of complete bowl assembly., cost towards making supplying and fitting s.s. top shaft as per size and sample., cost towards making supplying and fitting of c.i. spider bearing having od 6.5" with rubber bush as per size and sample., cost towards lowering of vt p/set. after complete repairing and assembling works., cost towards complete repairing of control panel at clear water pump house with changing of damaged parts such as :-1.125 amp tpn mccb,50 ka -1 no. as incoming feeder.2. 63 amp tp mccb, 50 ka-2no as outgoing feeder.3.star delta timer-2nos(one for each starter) 4. 32 amp switch fuse unit -01 no. for internal and external light load.5. (0-500 v) volt meter-01 no., ampere meter-01 no.,three phase indicator lamp,powder coating paint,push button on/off,on/off/trip indicator lamp,wiring,etc as per required and testing on full load .