Get complete information related to latest Volume Control Damper Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Volume Control Damper Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Volume Control Damper Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45726591 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at kashmir house under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, servicing of cassette type ac 3.5 to 4.0 ton capacity of any make / model with indoor and outdoor unit by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directednote: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 3.00 above but tower type ac of 2.0 to 4.0 ton capacity of any make / model any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., m&l for repair of unserviceable pcb of cassette/ tower ac of capacity 3.5 to 4.0 tr for both indoor/ outdoor units and refixing the same in respective units including opening & taking down existing unsv pcb complete all as specified and directed by engineer-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of cassette/tower ac of capacity 3.0 to 4.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by enginee

Central Government/Public Sector

CTN :45726596 Due date: 18 Jul, 202618 Jul, 2026 NA
Tender For repair/ maint of air conditioning systems alongwith its connected accessories at hq ids under ge new delhi - servicing of window type ac 1.5/2 ton capacity of any make / model by taking out the ac, cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing oiling of fan motor and checking of electric circuit for smooth functioning of ac complete all as specified and directed. note: the quoated rate includes the rates of minor parts i.e. starting relay, overload protector, thermostat, air filter synthetic/nylon as per existing size and shape, all as per item no 1.00 above but split type ac of any type and 1.5/2 ton capacity complete all as specified and directed, s&f in repairs running capacitor combination (50 mfd + 6 ) / (50+4) mfd 230 volt for ac upto 4.00 ton complete all as specified and directed, m&l for checking the leakage by feeding dry nitrogen to maintain adequate pressure in the system, plugging the leak and charging by charge refrigerant gas r-12/22/134a for water cooler, split type/window type ac/ deep freezer /refrigerator any size any capacity as on site complete all as specified and directed by engr-in-charge., m&l for replacement of reverse valve system suitable to 1.5/2 ton split/window ac for heating option (gas charging shall be paid and measured under respective item) complete all as specified and directed, supply & charging gas refrigerant r-22 /410 a/ or as existing to window type/split type/cassette/package type ac up to 4 ton capacity including removing of leakage if any and testing complete all as specified & directed by engineer-in-charge, m&l for repair of unserviceable pcb suitable for non inverter split type ac 1.5/2 tr and fixing the same complete all as specified and directed by engineer-in-charge., m&l for opening and taking down existing unserviceable pcb along with display unit and repairing & refixing of pcb along with display unit suitable for indoor unit of inverter ac of capacity1.5/2 ton split type ac complete all as specified and directed by engr-in-charge., m&l for opening and taking down existing unsv pcb and reparing & refixing of pcb suitable for outdoor unit of 1.5/2 ton split type ac inverter ac complete all as specified and directed by engr-in-charge., s&f pcb of non inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f pcb of inverter type split type ac of capacity 1.5 to 2.0 ton and fixing the same in respective units including opening & taking down existing unsv pcb complete all as specified & directed by engineer-in-charge., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 6.0 mm (1/4") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 13.0 mm (1/2") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 9.0 mm (3/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in replacement of of copper tubing and synthetic rubber tube insulation of thickness 9 mm & internal diameter - 16.0 mm (5/8") for refrigerant copper piping of split ac units complete all as specified and directed., s&f in repair drain pipe of any size suitable for split ac of capacity 1.5/2/3.5/4 tr as per sample complete all as specified and directed., supply only in replacement cordless remote for inverter type acs hot & cool suitable for 1.5 ton ac as per sample complete all as specif

CTN :45720849 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For procurement of spares for cooling towers (make-paharpur cooling towers limited) installed for cooling of circulating water for air compressor system and air conditioning system at u 7 and 8, ssctps, rvun, suratgarh - requirement of spares for cooling towers installed for cooling of circulating water for air compressor system in ahp area, model no. 6405m, grdr 20t rt-2.71:1 68-4592-1, fan assy 60in h-3-6 p85- (pcu-2/c) 3118-2, fill pack pc-47 p83-3128-1, d/s 6q cli 460 gb1.1/8 mb 38, spray nozzle p86-1082-3pp, elim pack stack pc-47 96-2034-17, branch pipe 50nb p85-1142-6, d/s coupling 6q with nbm insert gear side(gear shaft hole dia: 35 mm), d/s coupling 6q with nbm insert motor side(motor shaft hole dia: 48 mm), louvers, requirement of spares for cooling towers installed for cooling of circulating water of ac system in ca area, model no. 22103 for item s. no. 2.01-2.06 and model no. 3861 for item s. no. 2.07-2.10, fill sht mx75-8.1 lev p89- 4049-7, fill sht mx75-8.1 lev p89- 4049-8, fan assy 96in h-3-6, grdr 20t cc2, kit d/s 6q i nbm insert (rubber bush withhardware for drive shaft coupling), s.t. nozzle 68 3738-0xx pp, fill sht mx75-8.1 leh 86-4500-3, fill sht mx75-8.1 leh 86-4500-4, brg hsg assy sr118se, fan assy 54in h-3-6, requirement of stitching material for repair of damaged of frp structure of cooling towers, frp stiching material (fibre resin, fibre matstraid, mekp, cobalt, brush, chalk powder etc.)

CTN :45714448 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of butterfly valves (v2) as per is 13095 (q2) , pidbv with 3 way modulating valve and thermostat 65 mm dia , pidbv with 3 way modulating valve and thermostat 50 mm dia , pidbv with 3 way modulating valve and thermostat 40 mm dia , pidbv with 3 way modulating valve and thermostat 25 mm dia , pidbv with 3 way modulating valve and thermostat 20 mm dia , ms pipe 125 mm , ms pipe 100 mm , ms pipe 80 mm , ms pipe 65 mm , ms pipe 50 mm , ms pipe 40 mm , ms pipe 25 mm , ms pipe 20 mm , 125 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , 100 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , 80 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , 65 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , 50 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , 40 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , 25 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , 20 mm gi wire mesh with 15 mm cm 1 by 4 rendering over thermocol insulation , butterfly valve 25 mm , butterfly valve 20 mm , pressure gauge 0 to 100 psi , thermometer 0 to 50 degree , auto airvent with 15 mm dia , gi volume control damper , motorised on or off type actuator , 20 mm y strainer with ss perforated screen , 25 mm y strainer with ss perforated screen , 40 mm y strainer with ss perforated screen , 50 mm y strainer with ss perforated screen , 65 mm y strainer with ss perforated screen , 24g gi sheet metal duct 0 decimal 63 mm , 22g gi sheet metal duct 0 decimal 8 mm , 50 mm acoustic insulation for ahu room , volume control supply air diffuser , without volume control retur air diffuser , return air grill , fresh air grill with volume control , pre-filter 10 micron 600 x 600 x 50 mm , hdgi cable tray 300 x 50 x 1 decimal 6 mm , hdgi cable tray 150 x 50 x 1 decimal 6 mm , compressor oil rl 170 h , refrigerent gas r 22 or 134a , solenoid valve 220 v 50 hz , drier core filter for 12 decimal 5 to 30 tr ac plant , txv for 12 decimal 5 tr compressor

Central Government/Public Sector

CTN :45616921 Due date: 03 Aug, 202603 Aug, 2026 NA
Tender For supply of auto manual bypass rotary switch for air conditioning, current rating -16a, position: 3 (auto, manual, off), no. of poles - 7, as per sr. no. 57 of bill of material (bom) of rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-1), similar to l&t-salzer cat. no. 16a-d16-61031-b13-fhyr and conforming to rdso specification no. rdso/pe/spec/ac/0184-2015 (rev-1). suitable for use in switch board cabinet of lhb-type eog ac coaches. make (rdso approved): l&t-salzer or any other rdso-approved make. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted:max 8 lacs ] ]

Central Government/Public Sector

CTN :45576259 Due date: 22 Jun, 202622 Jun, 2026 NA
Tender For supply of compressor for roof mounted air conditioning system of three phase locomotives, conforming to rdso specification no. rdso/2007/el/spec/0055 rev 2 or latest equivalent to emerson model- zr28k3e-tfd-522. makes emerson copeland or from vendor list on u-vam with clw item id 2100134. [ warranty period: 30 months after the date of delivery ] ]

Central Government And Public Sector

CTN :45525671 Due date: 13 Jul, 202613 Jul, 2026 38.80 Lacs
Tender For renovation of supply air-conditioning system of k-4 and k5 with other accessories for rlg, barc, mumbai - design, fabrication, supply, installation, testing and commissioning of chilled water base double skin 10000 cfm ahu (without blower) as per clause no. 01 of technical specification., supply, fabrication and installation of ms supporting structures as per clause no. 02 of technical specification., design, supply, fabrication and installation of galvanized steel sheet for discharge air ducts as per clause no. 03 of technical specification., supply and installation of magnehelic gauge pressure range 0 to 25 mm wc including fittings as per clause no. 04 of technical specification., supply and installation of pressure gauges (0 to 7 kg/cm2 range) including fittings and ss ball valve as per clause no. 05 of technical specification., supply and installation of bar stock type ss thermowell with temperature guage as per clause no. 06 of technical specification., supply, fabrication, welding, installation, testing & commissioning of 80 mm nb schedule 40 carbon seamless steel pipe line including fittings as per clause no. 07 of technical specification., supply, fabrication, welding, installation, testing & commissioning of 100 mm nb schedule 40 carbon seamless steel pipe line including fittings as per clause no. 07 of technical specification., supply, fabrication, welding, installation, testing & commissioning of 125 mm nb schedule 40 carbon seamless steel pipe line including fittings as per clause no. 07 of technical specification., supply, installation, testing & commissioning of 50 mm size cpvc pipe with fittings as per clause no. 08 of technical specification., supply, installation, testing and commissioning of 100 nb mm dia flange ended gate valve ( ci body and gun metal internal)with suitable fittings and counter flanges for pipelines as per clause no. 09 of technical specification., supply, installation, testing and commissioning of 80 nb mm dia flange ended gun metal gate valve with suitable fittings and counter flanges for pipelines as per clause no. 9 of technical specification., supply, installation, testing and commissioning of 80 nb mm dia globe valve with suitable fittings and counter flanges for pipelines as per clause no. 10 of technical specification., supply and installation of all-around cold insulation saddles for chilled water pipeline along with fixing fittings as per clause no. 11 of technical specification., supply and installation of aluminium construction powder coated air diffuser along with volume control damper as per the clause no. 12 of the technical specification., supply and installation of 38 mm thickness close rubber cell cold insulation of classo fire rating followed by aluminium clading as per clause no. 13 of technical specification., supply, fabrication, installation and commissioning of the ss structural material including ss hardware. as per clause no 14 of technical specification., fabrication, supply and installation of ss construction multilouvered volume control dampers (vcd) along with electricaly operated modulating type actuator as per clause no. 15 of the technical specification., supply, fabrication and installation of plenum connection to existing blower as per clause no 16 of the technical specification., dismantling, segregation, removing & shifting of various equipment like ahu, insulated pipes along with supports, fittings, valves etc. as per the clause no. 17 of the technical specification.

Central Government / Public Sector

CTN :45549004 Due date: 01 Jul, 202601 Jul, 2026 NA
Tender For supply of auto manual bye pass, rotary switch for air conditioning current rating 16a, position-3 (auto manual off), no of poles-7 as per bill of material of rdso spec. no. rdso/pe/spec/ac/0184-2015 rev. 1 or latest similar to l&t- salzer cat no. 16a-d16-61031-b13-fhyr suitable for use in switch board cabinet of lhb type ac coaches. acceptable makes l&t/salzer/seimens. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

CTN :45512468 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For air cooled ducted 16.5 tr ac unit , air cooled ducted 5 tr ac unit , unloading lifting and shifting of 16.5 tr ducted package ac unit at site , unloading lifting and shifting of 5 tr ducted package ac unit at site , installation n2 pressure testing vacummising and commissioning of 16.5 tr ac , installation n2 pressure testing vacummising and commissioning of 5 tr ac , supply and charging of r 410 gas , supply and inst of floor mounted ms stand fabricated out of ms channel , supply and inst of floor mounted ms stand fabricated out of ms angel , hard copper refrigerant piping between indoor and outdoor units , supply and installation of gss ducting as 24g , supply and installation of gss ducting as 22g , acoustic insulation of plenum initial ducting with 10mm thick armasound , supply and fixing of 13mm thick nitrile rubber al foil faced insulation class i , supply and installation of ai powered jet nozzles with volume control damper , supply and inst of ai powered return air grills without volume control dampers , supply and installation of gi opposed blade duct dampers, qty 1.5 sqmtr , supply and fixing of canvas connection , supply and laying of 32mm dia pvc drain piping , electrical cabling 6 c x 1.5 sqmm cu flexible , electrical cabling 3 c x 1.5 sqmm cu flexible , electrical cabling 1 sqmm cu flexible double earthing * /bid number : gem/2026/b/7581741 + /dated: 11-06-2026 ' ' / bid document 1 / 24

Central Government/Public Sector

CTN :45473803 Due date: 07 Jul, 202607 Jul, 2026 NA
Tender For supply of set of energy saver for air-conditioning (acs). item no1-programmable, customizable, digital energy saver for window, split, inverter & non-inverter air conditioners - with 2 sensors & digital displays, temperature lock and a 14-point programmable for 1 & 1.5 tr air conditioners. item no2- programmable, customizable, digital energy saver for window, split, inverter & non-inverter air conditioners - with 2 sensors & digital displays, temperature lock and a 14-point programmable for 2 tr air conditioners [ warranty period: 12 months after the date of delivery ] ]