Get complete information related to latest Volumetric Pump Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Volumetric Pump Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Volumetric Pump Tenders.
Tender For providing of construction of drain for 2x210 mw ash water recirculation system at ptpp, parichha. - engaging jcb on hire bases including hire fuel driver helper etc. complete. , clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth upto 30 cm measured at a height of 1m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. , demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of material within 50 metres lead as per direction of engineer-in-charge in lime mortar , earth work in excavation by mechanical means (hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming ofbottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. , filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. , providing and laying in position cement concrete of specified gradeexcluding the cost of centering and shuttering - all work up to plinth level : 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) , providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - all work up to plinth level :1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - all work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size) , "centering and shuttering including strutting, propping etc. and removal of form for : suspended floors, roofs, landings, balconies and access platform" , steel reinforcement for r.c.c. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.thermo-mechanically treated bars , random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : cement mortar 1:6 (1 cement : 6 coarse sand) , brick work with fly ash (non modular) bricks of class designation 7.5 in foundation and plinth incement mortar 1:6 (1 cement : 6 coarse sand) , 12 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) , supplying and filling in plinth with jamuna sand under floors, including watering, ramming, consolidating and dressing complete. , "hire charges of pump set of capacity 4000 litres/hour for dewatering which include cost of services of operating staff, cost of lubricating oil, diesel / petrol/ kerosene oil , other consumables for running the plant and machinery. the hire charges of plant machinery on per day basis are for single shift of eight working hours." , providing and laying non pressure np-4 class (heavy duty) r.c.c. pipes including collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete 900 mm dia rcc pipes.
Tender For the detail of works includes:a. the tenderer shall carryout the following works during annual maintenance contract period along with the servicing of the diesel generator set.1. general checkup & preventive maintenance and to fill up preventive checkup schedule as follows:a) check lube oil level and conditioning of lube oil, top up/refill if required.b) the oil filters shall be replaced whenever oil is changed.c) the air filters shall be cleaned periodically with compressed air, check batteries and top up the distilled water if required.d) check functioning of changing alternator.e) engine safety viz. high water temperature gauge, oil temperature gauge and high speed gauge shall be checked for their functions and repaired/replaced if required.f) coolant level and conditioning of coolant shall be checked and refilled if required.g) check fan and alternator drive belts and tightened if required.h) the governor shall be checked and tuned for proper functioning.i) check for leaks if any and shall be rectified.j) check reports shall be submitted every month/every breakdown calls.2. checking and servicing of engine for smooth running, its unusual sound and color of smoke and exhaust and set it right in case of deviations.3. checking and repairing and leakage of fuel, lubricating oil and coolant.4. cleaning and changing of air filters as per requirement.5. setting of valves tappets whenever required.6. checking and repairing of accessories drive, turbo charger and crankshaft endplay whenever required.7. checking of alignment of engine & alternator as per requirement.8. checking of throttle control and its setting.9. checking of instrument panel including replacement as and when required.10. checking of rotating diodes assembly in brushless alternator including replacement as and when required.11. checking of wiring system and repairing/replacement as and when required.12. repair and maintenance of relays including contractors in control panel.13. checking of battery terminal and de-sulphating.14. diagnosis of faults in engine and alternator and its rectification.15. breakdown calls to be attended on priority within 6 hrs.16. providing spare avrs, self-starter and accessories, free of charge, if the repair/overhaul/replacement is expected to be taken in more than two days.17. checking/repair/adjustment/replacement/servicing shall be carried under annual maintenance contract except cost of component/parts to be replaced due to wear & tear.18. the firm should undertake to arrange genuine spares of the diesel engine, alternator and amf panel as and when required within two working days.19. the tenderer’s service engineer shall visit the site for attending the generator sets not less than twelve times during the contract period (minimum once in a month) and shall inspect the generator set thoroughly. each visit shall take place during 1st week of each month.20. the tenderer’s service engineer shall visit once in two month for checking of electrical side viz. alternator, amf control panel, if any.21. the engine shall be run on no load or at available load, and should be checked for any leakage and abnormal noise. if any such abnormality noticed shall be diagnosed and remedial action shall be taken.22. standard check list:a) replace minor parts (i.e hoses and filters etc) sub-assemblies as and when required.b) service engineers during the visit will report on the performance or any other abnormality and inform parts requirement. he shall also submit the report on work done and recommendations as well as spare parts required.c) attend emergency call on priority (usually same day). however, if the engineer is required or any particular date and time, it would be the responsibility of the customer to intimate the contractor in advance.d) major overhauling/ top overhauling / pt pump & injector calibration /replacement of major parts/ rewinding of alternator or repairs or breakdown of the diesel generator set are to be charge
Tender For supply of cummins engine spares c c - kit fuel filter and ring , valve shutoff , gauge temperature , valve solenoid , minor service kit , gasket lub oil fil cover , gauge lub oil pressure , bushing , seal oil , gasket rkr lever housing , pump sea water , primer engine lubricating , gasket set , element assy , kit air cleaner , seal o ring