Web Analytics Made Easy - StatCounter

Washing Tank Scrap Tenders

Get complete information related to latest Washing Tank Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Washing Tank Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Washing Tank Scrap Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45402768 Due date: 04 Aug, 202604 Aug, 2026 NA
Tender For corrigendum : construction of trench weir, power intake including river diversion arrangements, desilting tank, feeder pipe, tunnel, surge shaft, power house, hydro mechanical works of tankul shp (3 x 4 mw) on river simkholagad at tehsil dharchula in dist. pithoragarh of uttarakhand

Central Government / Public Sector

CTN :45675585 Due date: 08 Jul, 202608 Jul, 2026 NA
Tender For establishing connection from surge line to sump tank at serpl hyderabad to handle surge in station piping during receipt of atf

CTN :45048307 Due date: 31 Jul, 202631 Jul, 2026 NA
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp

CTN :45657677 Due date: 15 Jul, 202615 Jul, 2026 NA
Tender For tender for 1d_ cfd and stress analysis of erv-feeder tank , 1d_ cfd and stress analysis of erv-auxiliary tank , cfd and stress analysis of fuel filter , 1d_ cfd and stress analysis of iorv , cfd and stress analysis of jfs-fsov with filter , 1d_ cfd and stress analysis of surge relief valve , cfd and stress analysis of fsov dia 50 , cfd and stress analysis of electric vent valve

State Government

CTN :45660769 Due date: 10 Jul, 202610 Jul, 2026 NA
Tender For procurement of lightning materials for power houses at srhp, sikidiri. - led flood light, 120 watt, ip66, ik07, surge 10kv (as per technical specification mentioned in annexure ii of tender documents), led flood light (high surge outdoor type), 200 watt, ip66, ik08, surge 10-12 kv (as per technical specification mentioned in annexure ii of tender documents), led tubelight, 36/40 watt (as per technical specification mentioned in annexure ii of tender documents), led bulb, 9 watt (as per technical specification mentioned in annexure ii of tender documents), led bulb, 15 watt (as per technical specification mentioned in annexure ii of tender documents), led bulb, 30 watt (as per technical specification mentioned in annexure ii of tender documents), incandescent bulb, 100 watt (as per technical specification mentioned in annexure ii of tender documents), incandescent bulb, 200 watt (as per technical specification mentioned in annexure ii of tender documents), copper wire single core multistrand, 4 sq mm (as per technical specification mentioned in annexure ii of tender documents), copper wire single core multistrand, 2.5 sq mm (as per technical specification mentioned in annexure ii of tender documents), copper wire single core multistrand, 1 sq mm (as per technical specification mentioned in annexure ii of tender documents), hand lamp with 15 mtr wire, (2 x 1 sq mm) (as per technical specification mentioned in annexure ii of tender documents), halogen tube, 500 watt (as per technical specification mentioned in annexure ii of tender documents), halogen tube, 1000 watt (as per technical specification mentioned in annexure ii of tender documents), lightening arrester 11 kv (as per technical specification mentioned in annexure ii of tender documents), 80 mva digital meter, (digital temperature meter), range (300c to 1500c), model; no - 2274-t1(as per technical specification mentioned in annexure ii of tender documents), water tank (500 l) three layer (as per technical specification mentioned in annexure ii of tender documents), pvc valve (as per technical specification mentioned in annexure ii of tender documents), pvc valve 1 (as per technical specification mentioned in annexure ii of tender documents), pvc valve (as per technical specification mentioned in annexure ii of tender documents), pvc pipe 1 length - 3 mtr (as per technical specification mentioned in annexure ii of tender documents), c pvc pipe length - 3 mtr (as per technical specification mentioned in annexure ii of tender documents), pvc flexible water pipe (20 mtr) size - 1 (as per technical specification mentioned in annexure ii of tender documents), pvc thread socket (as per technical specification mentioned in annexure ii of tender documents), pvc plain socket (as per technical specification mentioned in annexure ii of tender documents), pvc connection pipe for wash basin (as per technical specification mentioned in annexure ii of tender documents)

CTN :45536277 Due date: 06 Jul, 202606 Jul, 2026 NA
Tender For procurement of 563 lines of rohini radar spare - bonded seal, bonded seal, bonded seal, bonded seal, bonded seal, coupling 1, coupling 2, coupling 3, turret mount for pump unit, pressure transmitter, resistivity controller, resisitivity sensor, temperature sensor, filter element, circuit breaker, mcb-plc/heater, mcb-main, contactors -9a, phase indication led, connectors 3 pin, pump channel-i 9 gpm, pump chanel-ii&iii 4 gpm, motor- fan, flow meter, micro filter housing assy, finned rediator, shock mount, hose 1 , hose , hose , hose , hose clamp , hose clamp , hose clamp , hose clamp 1 , plc-28 pt module, plc-analog module, plc rtd module, surge protector, circuit braker(mpcb), mmi 4 line display, push button, hexagon socket head screw, allen screw m10x25 12.9, socket head cap screw, socket head cap screw -, hexagon socket head cap b, socket head cap screwm10x4, socket head cap screw, m10x75 socket hd cap screw, socket head cap screw -, hexagon socket head screw, hexagon socket head screw, hexagon socket head screw, hexagon socket head screw, socket head cap screwm12, socket head cap screw, socket head cap screw m14, socket head cap screw, socket head cap screw, socket head cap screw, allen screw m16 x 80 12.9, socket head cap screw, socket head cap screw 10., socket head cap screw -10, socket head cap screw -10, socket head cap screw m6x, hex. socket head cap, hex. socket heacap, hex. socket heacap, cap screw m6x14, socket head cap screw m6, cap screw, cap screw m8 x 15, socket head cap screw m8x, socket head cap screw, hex. socket head cap screw, m10 x 25 l csk socket fla, m10 x 40 l csk socket fla, csk flat head screw, csk socket flat head scre, m10x65 hex head full third, hexagon head screw-class, hexagonal head class 10.9, socket head screw, hex head screw, m4 x20 cheese head screw, m6x15 cheese head screw, m6x20 cheese head screw m, cheese head screwm6 x25, spring washer, spring washer, spring washer, m6 spring washer, m8 spring washer, plain washer, plain washer, plain washer, plain washer, plain washer, m4 washer, plain washer, plain washer m8, spring washer is 6735, nut - class 12.9, m12 flanged nut gr 10.9, nut - class 12.9, nut - class 12.9, nut - class 12.9, m20 hex lock nut, hexagon head nut-class 12, hexagon head lock nut-cla, nut, m4 nut, nut, nut, nut - m8 ss, coolant, circuit breaker (mpcb), manetic wheel for flow meter, brss filter-3/4, o ring 1/2 nipple, o ring micro filter 123 id, o ring 3/4, hose assy pump inlet ch-1, hose assy pump inlet ch-3, 3/4, pump outlet;ch-1;filter1;3/4 x650, pump outlet;ch-2;filter1;1/2 x600, pump outlet;ch-3;filter1;1/2 x700, filter outlet, 1 to de ionizr, 1/2 x800, filter outlet,2 to tank, 1/2 x650, filter outlet,3 to tank, 1/2 x600, filter outlet,1 to twt, 3/4 x600, filter outlet,2 t0 twt,1/2 x650, inlet to rad, ch1 to rad 3/4 x 1500, inlet to rad, ch2 to rad 1/2 x 2000, inlet to rad, ch3 to rad 1/2 x2000, out rad ch 1, rad to tank 3/4 x 1500, out rad ch 2 , rad to tank 1/2 x 1700, pipe deion to tank 1/2 x 1200, level tube, phase sequence relay, aux relay for no/nc to twt panel, coupling gland, coupling gland, coupling gland, snubber for pressure transmitter, pump on/off push button, adapter 3/8 bsp, adapter 1/2 bsp, de-ioniser cartridge, distance piece ch. 2 (mandatory), heating element, cover micro filter, reservoir with fittings, base frame fan motor, control cabin with door, hose nut and nipple, hose nipple 1s pump, hose nipple 1d pump, hose nipple 2/3s pump thrd., hose nipple 2/3d pump thrd., hose nipple radiator thrd., needle valve 3/8 , drain plug, reservoir cap, bush, o ring 1 nipple, mmi to plc cable rj45, cable gland, cable gland, cable gland, reset button, led, cable main power, cable pump & fan motor, hose assy pump inlet ch-02 3/4", motor pump ch. 1 (mandatory), emi / eme flat gasket 1 mt l, fan control panel vent, distance piece ch. 3 pump & motor (mandatory), thrust washer for linkage, planetary gear reducer (azimuth gear box), clamp for dia 10 pipe, cl

Central Government And Public Sector

CTN :45531499 Due date: 16 Jun, 202616 Jun, 2026 NA
Tender For auction sale of depot non ferrous scrap - 98230062 ¿ aluminium alloy scrap (consisting of aluminium water tank with surge damper,chequered plate,aluminium d.v, rear cover,front cover,cut piece of aluminium moulding and various types of parts and fittings of abs and signal deptt.etc)

Central Government / Public Sector

CTN :45268110 Due date: 11 Jun, 202611 Jun, 2026 11.38 Lacs
Tender For corrigendum : supply and installation of roof drain flexible hose for surge tank (500 kl) and other mechanical maintenance works at phbpl barauni

State Government

CTN :45347661 Due date: 24 Jun, 202624 Jun, 2026 NA
Tender For supply of procurement of radar level transmitter for continuous urea solution surge tank level measurement

CTN :45322644 Due date: 01 Jun, 202601 Jun, 2026 8.70 Lacs
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh
 Loading, Please wait...

Connect us via What's Up