Tender For works related to storm/cyclone (natural calamity) within the limits of v.v.khan., banda (city). - the work of special maintenance and repairing of 11 kv ht and lt damaged lines of various places under various 33/11 kv sub-stations due to heavy storm under daiviya apada/o&m year 2025-26 under edd, banda (town), including carriage of all required material from esc banda to work site, alongwith its loading, unloading & dragging at the respective ends and also safe carriage of old line material/scraped from site to store centre. the bidder shall be responsible for complete execution of the work under the scope of tender specification. any work/activity not specifically indicated but is required for systematic execution of job shall be carried out by the contractor without any extra payment. the material supplied by contractor should be the best quality and as per standard including transportation, if any. details of the work as given below ;-, safe cartage of 8.5 mtr. long pcc poles, safe cartage of 11 mtr. long st poles, safe cartage of line material, erection of newly erected 8.5 mtr. long pcc poles as single support structure, including complete ht/lt fittings as per direction of engineer incharge/resspo manual., erection of newly erected 11 mtr. long st poles as single pole structure, including complete ht/lt fittings as per direction of engineer incharge/resspo manual., erection of newly erected 8.5 mtr. long pcc poles as double pole structure, including complete ht/lt fittings as per direction of engineer incharge/resspo manual., erection of newly erected 11 mtr. long st poles as double pole structure, including complete ht/lt fittings as per direction of engineer incharge/resspo manual., concreting/grouting of newly erected 8.5 mtr. long pcc poles as single support/double pole structures. the support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 cu. mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge., concreting/grouting of newly erected 11 mtr. long st poles as single support/double pole structures. the support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 (0.285 cu. mtr. each), including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement & direction of enginner incharge., erection and grouting of stay set including the work of nozelling etc. as per resspo manual and also including the cost of all grouting material., fixing of earthing rod as per direction of supervising engineer/resspo manual. including the cost of labour, t&p etc. required for proper completion of work., laying, sagging, stringing, binding and jumpering of new acsr weasel conductor on the erected poles in 11 kv ht/lt lines also providing in-place of damaged/misplace conductor due to heavy storm., laying, stringing, binding and termination etc. of abc cable of various size on the erected poles as per direction of supervising engineer/resspo manual., re-sagging of loose conductor of 11 kv ht lines at various places., re-sagging of loose conductor of lt lines at various places., dismentling & removal of existing/erected old & damaged pcc/stp/joist/rail poles as single pole structure with its accessories., dismentling & removal of existing/erected old & damaged pcc/stp/joist/rail poles as double pole structure with its accessories., carriage of damaged/rusted st/rail/joist poles from work site to esc., replacement of damaged/misplace "v" type cross arm, guarding with fitting of all accessories as per resspo manual., dismentling & removal of damaged weasel conductor with its accessories due to heavy storm and also cartage of old/damaged & scrap line material from work site to store centre/je(s)., straightening of tilted single support as 8.5/11.0 mtr. long
Tender For tender for supply of equipment / material, design, erection, testing, commissioning for providing s.o.p. to newly constructed residential building at nift campus chebb at kangra under esd no. i hpsebl, kangra. - (a) material/erection of 11/0.4kv,250 kva s/stn., prov.distribution transformer (ordinary), 11/0.4 kv, 250 kva, prov.steel tubular poles (9 m, working load > 200 kgf/m ), prov.x-arm: [channel iron (100x50x5 mm), length : 2800 mm x 2 nos] for incomer line, prov.ms angle iron (50x50x6 mm), length: (2800 mm) x1 nos for las, prov.x-arm: [channel iron (75x40x6 mm), length : (2800 mm x 4 nos] for supporting do fuse unit & go switch, prov.x-arm: [channel iron (100x50x5 mm), length : 2800 mm x 2 nos] for transformer bed, prov.x-arm [channel iron (100x50x5 mm), length : (460 mm) x 2 nos for supporting main channel of transformer], prov.ms angle iron (50x50x6 mm), length : (2800 mm) x 2 nos, prov.ms angle iron (35x35x6 mm), length : (460 ) x 2 nos, prov.ms angle iron (50x50x6 mm), length : (950 mm) x 2 nos for bed knee bracing, prov.ms angle iron (50x50x6 mm), length : (2800 mm) x 2 nos, prov.ms angle iron (50x50x6 mm), length : (450 mm) x 1 nos, prov.go switch handle supporting: [channel iron (75x40x6 mm), length : 460 mm, prov.d.o fuse unit, prov.surge arrester, 9 kv station class (porcelain type), prov.discs insulator sets (comprising 1 no. disc: ^^(porcelain, bs, 12kv, 90 kn) including dead end clamps etc.), prov.pipe earthing set, lt distribution panel box with mccb(630a, 50 ka, 3p,1 no) and mccb(250 a, 36ka, 3p, 3 no.), prov.half clamp (m.s. flat 50x6 mm), prov.full clamps (m.s. flat 50x6 mm), prov.nuts and bolts of various sizes (galvanised / coated) [preferably 16 mm or more (with flat and spring washers)], aluminium thimble, copper thimble 200 amp, danger plate, prov.barbed wire, prov.energy meter (3-phase,4-wire)dlms compliant 400/5a ct type, prov. aluminium paint., prov.aaac 7/3.15mm conductor for earthing, erection charges complete in all respect, transportation charges complete in all respect, (b)material/erection of 11 kv ht line, prov aaac 7/3.15mm conductor (50mm ) {includes cutting and wastage}, prov. steel tubular poles (9 m, working load > 200 kgf/m ), prov.m.s. c.i.x-arm (1500x100x50x5 mm), long for single pole, prov.m.s a.i x-arm (1800x50x50x6 mm), long for single pole, prov m.s a.i x-arm (50x50x6 mm), length (2x750) mm long for single pole, prov m.s a.i x-arm (50x50x6 mm),length (2x600) mm long for single pole, prov.m.s c. i cross arm (75x40x5 mm), length (2400) mm for g.o switch & d.o fuses, prov.belt set - ms a.i 50x50x6, length [2400 mm x 2 no.] for double pole, prov.x-bracing set - ms a.i 50x50x6, length [2700 mm x 2 no.]for double pole, prov 11 kv pin insulators (porcelain, 12 kv, 10 kn), prov disc insulator ,1 no disc (12 kv, 90 kn) including dead end clamps etc., prov ht earthing set complete, prov double continous earth wire (gi, 8 swg) @ 0.102 kg/m, prov danger plate (250x200x1.6 mm), prov nuts and bolts of various sizeswith flat and spring washers, prov barbed wire, prov aluminium paint, prov.full clamps (m.s. flat 50x6 mm), prov.xerox for chebb s/stn for scada, prov.d.o fuse unit, erection charges of 9 mtr st pole complete in all respect, erection charges of stay set complete in all respect, erection charges of coil earthing complete in all respect, erection charges of g.o. switch complete in all respect, erection charges of sagging aaac 7/3.15mm conductor, sagging of continous earth wire (gi, 8swg) @ 0.102 kg/m complete in all respect, transportation charges complete in all respect, commissioning of a 250 kva dtr plinth and fencing, earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kinds o
Tender For supply of wormdrivehoseclamp 70 mm conforming to is 4762: 2002. make/brand: klipco (or) hylite or equivalent. [ warranty period: 30 months after the date of delivery ]
Tender For supply of wormdrivehoseclamp-40 mm for general purpose. matl.& specn:is:4762/200 2 (reaffirmed year 2021) [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : daiviya apda work under edsd- rura - carriage of various size pcc poles from store center or from any other place to the respective site of work distence up to 75 km through the kachha pacca road including the work of its loading & unloading at the respective ends also including the work of its dragging etc. and also including the cost of labour, t & p and carrier etc. required for proper completion of work., carriage of various size st poles (9 mtr /11mtr/ 13mtr ) from store center or from any other place to the respective site of work distence up to 75 km through the kachha pacca road including the work of its loading & unloading at the respective ends also including the work of its dragging etc. and also including the cost of labour, t & p and carrier etc. required for proper completion of work., carriage of line material viz. weasel/rabbit/racoon /dog conductor, g.i. earth wire, cross arm, angle, channel, cable boxes, static meter insulators, clamps and other line material from store center or from any other place to the respective site of work through the kachha pacca road including the work of its loading & unloading at the respective ends also including the work of its dragging etc. and also including the cost of labour, t & p and carrier etc. required for proper completion of work., erection of p.c.c double pole including the work of complete h.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t & p and carrier etc. required for proper completion of work., grouting of p.c.c double pole the support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement., erection of p.c.c single pole including the work of complete h.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t & p and carrier etc. required for proper completion of work., grouting of p.c.c single pole. the support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement., erection of s.t.p single pole including the work of complete h.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t & p and carrier etc. required for proper completion of work., grouting of s.t.p single pole. the support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement., erection of s.t.p double pole including the work of complete h.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t & p and carrier etc. required for proper completion of work., grouting of s.t.p double pole. the support shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of arrangement of cement, sand, brick ballast/stone ballast, stone pad etc. as per actual site requirement., renozzling of damaged stay set as per respo manual and also including the cost of all grouting material, labour, t & p etc. required for proper completion of work., dismentling of rusted weasal/racoon /dog conductor wire and g.i wire & safe carriage of scrap material back to store as per respo manual and as per direction of supervising engineer. it includes the cost of labour, t & p, carries etc. required for proper completion of work., laying, sagging, stringing, binding and jumpering etc. of weasal/dog/rabbit conductor in new erected pole as per respo manual and as per direction of supervising engineer. it includes the cost of labour, t & p, carries etc. required for prope
Tender For supply of set of porcelain stay arm insulator and post insulator suitable for 25kv ohe arrang ement, as per the details enclosed. item not available in gem [ warranty period: 30 months after the dat e of delivery ]