Get complete information related to latest Duct Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Duct Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Duct Tenders.
Tender For supply of cable duct a 45 cover,in standard slot grey, as per drawing: cat no cda45sg,packing instruction: as per standard packing. it should be ensured that item should not rub during transportation. the item should be packed with adequate strength. transit damage , if any , shall be at the cost of supplier. [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For corrigendum : repair / replacement and maint of lt external electric supply works and other connected items at east & west wing in tech area under ge (af) tech area gwalior - s&f in repair mccb, 4 pole, 630 amps current rating and ultimate breaking capacity ics=icu =100% 36 ka with adjustable overload setting and having thermal magnetic release and to be fixed in distribution board, complete all as specified and directed., all as per item here-in-before but mccb, 4 pole, 400 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 315 amps current rating and ultimate breaking capacity 36 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 250 amps current rating and ultimate breaking capacity 36 ka. ics = 100% of icu, all as per item here-in-before but mccb, 4 pole, 160 amps current rating and ultimate breaking capacity 36 ka . ics = 100 % of icu, all as per item hereinafter but mccb, 4 pole, 125 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 100 amps current rating and ultimate breaking capacity. 16 ka. ics = 100 % of icu, all as per item here-in-before but mccb, 4 pole, 63 amps current rating and ultimate breaking capacity .16 ka . ics = 100 % of icu, m&l for earthing complete with galvanised steel plate electrode 600x600x6mm thick buried directly in ground (top edge of the plate should not be less than 1.50mtrs below ground level) connected to gi strip 25 4mm by means of bolts, nuts check nuts and washers of galvanised iron or steel connected to earthing test point all as specified incl 20 mm gi tubing medium grade and necessary fitting for protection of gi strip incl laying of charcoal dust and common salt in alternate layers of 150mm th, pcc chamber using pcc(1:3:6) type c-1 using 20mm graded stone aggregate, rcc cover 40mm thick (1:2:4) type b-0 using 12.5mm graded stone aggregate reinforced with 6mm dia round bar @ 75mm c/c both ways with ms handle 8mm dia, plastering 15mm thick cm (1:6) externally up to 150mm below ground level, gi funnel with 20mm dia medium grade gi pipe for watering and wire mesh incl excavation and earth work and disposal of surplus soil complete all as specified and shown on electrical plate no.3 of ssr part-i (2009) and connected to earth test point incl testing and marking bldg nos and writing test results (in white) on a black painted m.s. plate (size 300x300x3mm th) duly welded with angle iron of size 40x40x5mm, 60cm long, fixed with the earth pit chamber by grouting complete all as specified and directed.note :- (i) gi strip 25 4mm and gi pipe medium grade, up to 7.5mtr shall be deemed to be included in the rates quoted for earthing.(ii) excavation and earth work in any type of soil strata shall be deemed to be included in rates quoted for earthing. (iii) the rates quoted by the contractor are deemed to be included for pcc chamber and pcc cover as per ssr part-1.-, m&l for preparation of old painted surfaces of lt steel tubular pole/strut, of any description and in any position 9.00/8.50 mtr height and scrapping of pole with emery paper and applying one coat of aluminium paint on all the metallic surfaces including protection pipe, cross arms, clamps, gi pipe bracket of street/security light, anti climbing devices etc and providing three nos radium band strips complete all as specified and directed., supplying ,laying, jointing and testing xlpe insulated, armoured, heavy duty, aluminum conductor cable 1100 volts grade ,laid in trenches/ducts, floors, fixed to walls etc. complete all as specified and directed for the following sizes.note: the cost of taking down of lt ug cable is deemed to be included in the quoted rate, 35 sqmm 3 core, 50 sqmm 3 core, 70 sqmm 3 core, 185 sqmm 3 core, 240 sqmm 3 core, excavation in trenches n exc 1.5 mtr wide and n exc 1.5 mtr depth for foundation and laying of cable and get
Tender For supply of air duct covering plate for hhp actm as per drg no 4/plw/m/tm-sk-127 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For auction sale of depot ferrous scrap - lot of scrap consisting of ferrous junck & corroded material buried in soil, tree, trapped under earth, within bushes, grass, shrubs. lot consisting of mf10 type materials rusted and corroded condition of different type materials liker verious size,, nuts, bolt, rivets,chains, coil spring,air spring assmbly,& suspension with or without rubber attachment, spray tin bottles,small drum capacity 4 ltrs damage condition, electrical boxes,signal boxes,and other boxes, locking plates, cut piece of iron wire, ms iron strip, sheets & cut pieces iron plate, cycles, signal rod, coupler rods,air fillter, hand brake wheel , sackle pin etc,cut pieces of pipes with or without ci. attachments, filters, junk cylinders, junk doors, junk cut pieces of angles ,channels and bars, small parts of c&w and electric loco items junk kuchra, tube light fitting, electric fitting with or without non - ferros attachment etc. different type iron bed,chairs with or without cushan, almirah, table,cooler duct, pipe, rod, bunch of wires, with or without slightly non- ferros & ss attachment etc. fully formed or broken condition as available as in the lot. excluding rail wheels, rails, axle, trolly and cs/1,mt/1 materials. nb:- manual digging and collecting by purchaser on his own arrangement from soil.
Tender For bid to ras supply of m and l in repair for heat shrinkable straight through jointing kit , supply laying in repairs in trenches ducts fixing , taking out carefully cable covers and ht cable from excavated , relaying of ht cable of size 120 sqmm 3 core in trench , excavation in trenches not exceeding 1.5 mtr wide and 1.5 mtr depth , excavation in trenches not exceeding 1.5 mtr wide and depth , removing excavated materials not exceeding 50 m and depositing where directed , returning filling including spreading levelling watering and well ramming , supply and lay sand cushioning to underground ht cable complete , supply and lay reinforced precast concrete cable cover , lay only precast concrete cover size 450 230 50mm , m and l gi pipe light grade with all fittings , m and l for pcc type c2 40 mm graded stone , s and f of dgset 500 kva 3 phase with cpcb iv norms , xlpe pvc insulated cable 3.5 core 300 sqmm , m and l gi pipe light grade with all fittings complete , earthing with gi earth plate electrode 60 60cm 6 mm buried , taking out carefully existing ber dg set from ekm complex area * /bid number : gem/2026/b/7625309 + /dated: 16-06-2026 ' ' / bid document 1 / 21
Tender For supply of ug bkr fsc : - suppy and construction of ug bunker fsc , cement of 43 grade opc , river sand , stone aggregate 40 mm , stone boulders for hard core , placing of ug bunker , video camera based entry system , hot and cool air conditioner , tunnel ventilation system , high efficiency heat exchanger , fire alarm system , hepa filters , activated carbon filters , pressurized oxygen tank , high efficiency solar panels , supply comma installing comma testing and commissioning , multi angle digital camera system , provision of duct for two way , installation of layered led lighting , highly efficient foldable table , modular storage racks , cool glove box , lockable compartments , gi plate 600mm x 600mm x 6mm , gi wire 4 mm , cast iron cover , charcoal , common sal , gi pipe 20 mm , nuts and bolts , lightening conductor , entrance canopy
Tender For repair/replacement of capacitor bank, sign board, fencing cable duct cover, route indicator and miscellaneous work at various sub station/installation at af stn gwalior.
Tender For corrigendum : repair to security lights panels dg sets fire alarm ups with covered items at af stn bikaner under ge (af) nal - excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m depth, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed by engineer-in-charge., removal of excavated material soils to a distance n exc 50 m and depositing where directed at a level not exceeding 1.5m above the startly point complete all as specified and directed., returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm as in any type of soil complete all as specified and directed., material and labour for sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers complete all as specified and directed. note : punned thickness shall be measured for payment., material and labour for un-reinforced pre-cast concrete cable covers, class lv type-1, flat size 250mm x 150mm x 40mm thick complete all as specified and directed., taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 6 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 2 core, 10 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 4 core, 16 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 25 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 35 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, taking out defective cable xlpe/pvc sheathed 1100 volt grade heavy duty armoured with aluminum conductor 3.5 core, 50 sqmm from trenches complete all as specified and directed.note : excavation and earth work shall be measured and paid for separately under relevant item, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 6 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge , supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 2 core 10 sqmm laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 4 core 16 sqmmlaid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed by engineer-in-charge, supplying, laying, jointing and testing of under ground cable xlpe insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor 3.5 core 25 sqmm laid in trenches
Tender For corrigendum : repair/maint of external electric supply system, distribution lt panels with connected items and allied services at other than basistha area under ge guwahati. - excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep for taking out / laying of under ground cable, pole or stay and getting out in soft soil strata complete all as specified and as directed., returning filling in including spreading leveling watering and well ramming in layers not exceeding 25cms spread any type of soil complete all as specified and as directed., removing excavated materials not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed., supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (note : punned thickness shall be measured)., m&l for bricks common burnt clay, building brick, sub class b designation 75 old size bricks laid in trenches flat over sand cushioning for cable protection complete all as specified and as directed., m&l for supply and fixing / laying in replacement, connect, test and commissioning of lt under ground cable xlpe insulated, screened, pvc bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of ms saddle clips (where ever cable laid in ceilings / walls without cable duct) complete all as specified and as directed.note : manufacturers test certificate shall be submitted alongwith rar/fb to engr-in-charge., (a) 95 sqmm x 3.5 core, (b) 70 sqmm x 3.5 core, (c) 50 sqmm x 3.5 core, (d) 25 sqmm x 3.5 core, supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 630 amps, 50ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 400 amps, 36 ka breaking capacity with overload and thermal tripping feature with magnetic release, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 250amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 160amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, tpn (4 pole), 125 amps, 36ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 100amps, 26ka breaking capacity with overload and thermal tripping feature, 415volts ac, 50hz, icu = 100%, including certain addition or alteration if required at site complete all as specified and directed., supply and fixing in repair, connecting, testing and commissioning mccb in panel etc. mccb, 4 pole, 63amps, 16 ka breaking