Get complete information related to latest Mattress Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mattress Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mattress Tenders.
Tender For supply and installation of coach set of seats and berths for lscn/bw2 coach to drawing lscn/bw2(753)-6-1-001, alt -d, col-01 (except item 25,26,27 and respective hardware for fitting) cushioning material shall be pu foam as per rdso specification no.rdso/2007/cg04, rev-01 or latest and upholstery to rdso spec.rdso/2008/cg-07 ,rev-01 or latest. installation required as per arrangement drawing. all necessary hardwares required for installation is under scope of the supplier. note: firm has the option for offering seats and berths cushion with lower density of 65 plus or minus 5 kg/m3 conforming to spec.rdso/2007/cg-04, rev-01 or latest also. please visit icf vendor portal for downloading drawing https://vp.icf.gov.in/vendtendordetnew.php using key:0726ob8qu4v2382 [ warrantyperiod: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply and installation of 3-seater complete for 1st class (double) to drg.no.icf/mrvc/c/bt-6-1-002,col-i,alt-b. cushioning material shall be pu foam to rdso specn.rdso/2007/cg-04,rev-01 and upholstery to rdso spec.rdso/2008/cg-07, rev-00,amd-01 to 05. note: firm has the option for offering seats and berths cushion with lower density of 65 plus or minus 5 kg/m3 conforming to spec.rdso/2007/cg-04, rev-01 or latest also. please visit icf vendor portal for downloading drawing https://vp.icf.gov.in/vendtendordetnew.php using key:07261dxvfiz1237 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply and installation of 3-seater complete for 1st class (double) to drg.no.icf/mrvc/c/bt(573)-6-1-002,col-i, alt-b. required cushion and upholstery material will be supplied by icf as free supply. all necessary hardwares required for installation is under the scope of supplier. please visit icf vendor portal for downloading drawing https://vp.icf.gov.in/vendtendordetnew.php using key:07266grwovq2204 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of set of seat and berth for crews, guard compartment & disabled compartment for lhb slrd hog coaches. follow cushioning material either pu foam to rdso spec. rdso/2007/cg-04 rev. 01 or silicon foam to spec. rdso/2013/cg-13 rev. 01 and upholstery to rdso spec.rdso/2008/cg-07 rev-nil with amendment slip no-5 and corrigendum 1 of may 2015. follow colour shade alnac-03 for upholstery and ral-9006 for painting of visible metallic portion todrg/set list no. mplsbaslrd version 0. follow packing instruction pi 117 ver. 10. [ warranty period: 54 months after the date of delivery ] ]
Tender For supply of set of seats for 3-phase memu/dmc coaches. follow cushioning material either pu foam to rdso spec. rdso/2007/cg-04 rev. 01 or silicon foam to spec. rdso/2013/cg-13 rev. 01 and upholstery to rdso spec. rdso/2008/cg-07 rev-nil with amendment slip no-5 with corrigendum 1 of may 2015. colour shade alac-01 for upholstery as per lno.md22151 dtd.18.06.2019 , as per drawing: memu/dmc/3ph-6-1-001 alt-ar w/o item no.6, packing instruction no.pi183 ver2.0 [ warranty period: 54 months after the date of delivery ] ]
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of ms channel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For repair/ replacement of lt cable, lt panel and connected items in domestic area (excluding camp area), su site 1a and 1b at af stn jodhpur - excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n. exc 10 sqm on plan and getting out in soft/ loose soil complete all as specified and directed., returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil.complete all as specified and directed., removing excavated materials to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point in any type of soils.complete all as specified and directed., m&l for sand cushioning for xlpe cable with tibba sand (one layer of 80mm thickness before laying of cable and other layer of 150mm thickness after laying of cable) and punning down to 180mm to provide a required cover complete all as specified and directed by the engineer-in-charge.note:- punned thickness only shall be measured and paid., m&l for protection to cable with one layer of bricks laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable using old size sub-class b bricks complete all as specified and directed by engr-in-charge., supplying and laying un-reinforced precast concrete cable cover, class lv, type i, flat, size 250mm x 150mm x 40mm confirming to is - 5820 complete all as specified and as directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 16 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm, 4 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 35 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 50 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 70 sqmm, 4 core laid in gi pipe complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 95 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable laid in trench with aluminium conductor, 1100 volts grade, cross-sectional area 150 sqmm, 3.5 core complete all as specified and directed., supply and laying of xlpe insulated, armoured, heavy duty, electric cable, laid in ground with aluminium conductor, 1100 volts grade, cross-sectional area 240 sqmm, 3.5 core complete all as specified and directed., taking down of lt cable any size from trech/ gi pipe/ walls/ on ground/ street light poles complete all as specified and directed., m&l for boring of holes under road, pavement, hard stansding by using manual method with 100mm hdpe pipe complete all as specified and directed by engineer-in-charge., s&f in repair mccb 400 amp, 4 pole, 415 v, 36 ka, thermal megnatic adjustable type complete all as specified and directed., s&f in repair mccb 250 amp, 4 pole, 415 v, 35 ka, thermal megnatic adjustab
Tender For special repairs to lt panels and connected items at pyro, pinaka, nag mixture building, magazine area and ap building in hemrl, pune - taking out old serviceable/unserviceable lt panel/capacitor panel of any description or capacity keeping aside in safe custody for schedule of credit complete all as specified and directed, supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 nos, (c) mccb 4p, 125 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 200/5 - 04 nos, (e) control mcb c curve, sp, 6 to 32a, 10ka, c curve - 02 nos, (f) led phase indicator (r,y & b) - 01 set. (pyro sub stn), supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, ms channels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (c) mccb 4p, 315 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) mccb 4p, 250 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 nos (e) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 800/5 - 04 nos, (e) con