Get complete information related to latest Mattress Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mattress Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mattress Tenders.
Tender For 25 kv earthing/discharge rod assembly for high rise ohe with working voltage 25 kv ac traction with top clamp (suitable for 36 to 50 mm bus bar and also suitable for 10 to 20 mm dia. conductor) . pole made of cast resin or resin-bonded glass fibre, coated with three coats of poly- urethane, the discharge /earthing pole assembly shall have an overall length of not less than 7.5 meters in five equal sections. single core flexible multi strand annealed copper cable should have double insulation, a cross section of 40 sq mm of size 248/0.45 mm and 14 meter long cable (specification is: 1554 (pt. i)- 1988 and is 2071 (pt. 1 and iii). with earthing double clamp drg. no. eti/ohe/sk/482 or latest (each discharge rod is to be supplied with 02 nos. earting clamps), insulated tee junction- insulated tee junction drg no. eti/ohe/sk/481 and re/33/p/530 or latest (the cable should have an insulated tee junction and the tee clamp should be of brass covered in clamp casing of ebonite material). and whole assembly to be supplied in rugged canvas bag and all shall be as per rdso specification no. eti/ohe/51 (9/87) with latest a and c slip no. 1 (10/92) or latest , and additional part required with each discharge rod to be supply. (1) 01 nos. insulated tee junction. (2) 01 nos. top clamp made of copper suitable for 36 to 50 mm bus bar and also suitable 10 -20 mm dia conductor, (3) 01 nos. spare earthing clamp and. (4) special instruction- 1. discharge rod cable lugs should be made of copper. 2. the cable should have double insulation, a cross- section of 40 sq mm, and 248/0.45 mm strands. 3. the discharge rod should be strong enough to prevent swaying or breaking during maximum extension. every nut and bolt used in the discharge rod must include a washer and spring washer to ensure secure fastening. 5. after the award of the p.o., the firm must ensure approval of one sample of the discharge rod from the consignee before rites inspection. 6. the length of cable from the earthing clamp to top clamp shall not be less than 12.5 mtr. in the cable an insulated tee junction shall be provided at a distance of about 3.5 mtr from the earthing clamp. from this insulated tee junction another piece of cable not less than 1.50 m long shall be provided at the end of which other earthing clamp shall be provided. 7. the galvanized steel tube (threaded) used for coupling of pieces of discharge rod should be at least 20 cm or more as required to prevent swaying of pole assembly during erection at site. also at every 5 cm apart two nos steel rivet is required to be provide on galvanized steel tube ( for preventing the galvanized steel tube from coming out from each discharge rod pole end). i.e. about 08 nos. or more steel rivet as required per galvanized steel tube is to be provided for proper fastening of galvanized steel tube inside the each pole of discharge rod. (warranty period- 30 months after the date of delivery). [ warranty period: 30 months after the date of delivery ]
Tender For corrigendum : pvc insulated flexible copper cable 4 co [pvc insulated flexible copper cable 4 core per core size 16 sq.mm, voltage rating up to 1100 v, confirming to is 694:2010 or latest, 126 strand of 0.4 mm diameter, frls, sheath type st-3, black in colour, conforming to rcf specification no. edts-004. material make is axelon or ristacab or finolex or kei or rr kable or polycab or v-guard or anchor or havells note: firm should supply proof of purchase from oem or authorized dealers only. firm should supply test certificate & guaranty certificate along with supply of item.]
Tender For supply of provn of 01 x mt shed shelter part and double swing chain link gate with chain link fence as per drawing atteched , pvc casing capping 25mm wide comma not less than 2mm thick , pvc indulated , surface and wall mounted led tube rod 20 watt comma 1600 lumens output comma 4 feet long , mcb db 4 way spn comma 240 volt conform to is hyphen 13032 dot , mcb 32 amp sp comma 240 volt conform to is hyphen 13032 dot , insolator dp 40 amp dp 240 volt comma 50 hz , pvc switch board 8 inch x 10 inch , socket pt 15 forward slash 16 amp comma 240 volt , socket pt 5 forward slash 6 amp comma 240 volt , 1 sqmm single core multi stranded copper conductor , 1 dot 5 sqmm single core multi stranded copper conductor , insulation tape 19mm width comma 25m long dot bracket open make colon steel grip forward slash anchor forward slash finolex bracket close , piano type switch 5 forward slash 6 amp , piano type switch 15 forward slash 16 amp , black screw full threaded 1 inch , earthing colon electric earthing set complete , lightening conductor with safe chemical , provn of construction material for mt shed dot
Tender For supply of amc of breaker and panels at loni : : =servicing of sf6 22kv , servicing of vcb 6. 6kv , servicing of lt 415v acb , vcb interrupter testing as per oisd 137 , 22kv and 6. 6kv vcb otc , 22kv and 6. 6kv vcb crt , breakdown visit at loni , testing calibration of oti , testing calibration of wti , thermography of panels at loni , ht and lt relay testing at loni as per enclosed list. , testing of insulation mats at loni , testing of insulation mats at sv1, sv2, sv3 and mov6
Tender For supply of naval store item c c -urinal screen mats , spray hand liquid insecticide , mosquito repellent machine with liquid , refill for automatic air freshner 250 ml , rat sticking gel , ncml solution teepol qty for 06 months , ncml solution phosphoric acid qty for 06 months , ncml solution oxalic acid qty for 06 months , ncml solution thiourea qty for 06 months
Tender For supply of ups point wiring : -material and labour point wiring for pin socket , material and labour 20mm dia independent boards controlled by one way switch pvc casing caping , supply and fix switch socket combination 2 in 1 multipurpose pin , supply and fix switch socket combination 5 in 1 flush type controlled by 1 switch , material and labour for sub main wiring with two run of frlsh insulataed single core multi stranded copper conductor , supply and fixing powder coated sheet metal enclosures , supply and fix mcb spn 40 to 63 , supply and fixing mcb spn 32 amp , supply and fixing mcb sp 6 to 32 amp