Get complete information related to latest Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Tenders.
Tender For restoration of rain damages to wss sukretha dullar in gp dullar tehsil & distt. chamba hp(sh:-excavation, laying jointing dismentalling & relaying of gi pipe of various dia at various rd).
Tender For restoration of rain damages to wss kharori dhar in gp kandla tehsil & distt chamba hp (sh:- excavation laying & jointing dismentelling & relaying of gi pipe of various dia at various rd).
Tender For supply of apfc capacitor bank panel - supply, instalation and commissioning of apfc capacitor bank panel with apfc relay with automating load control panel of 1250 kvr trail testing of apfc panel and outgoing supply of feeder will be connection and load trial. as per bellow detail specification make- l & t details of fabrication of panel cubical- free standing floor mounted with ismc chanel base 100x50x5mm front oprated indoor type ip44, powder coated, color-siemens gray ral-7035)hardwae, gasket,door lock, wiring, ferul etc sheet 2.2/1.6mmmm crca. note - 1-1- panel will be ms fabricated and powder coated as per industry standard, 2-all wires will be used fire proof standard. 3-the paneles muist be of iec/nec standards.4- all type of modification of old bus duct as per requiredment of sit.5- panel coolling axial fan 8inch/panel illumination lamps/thermo stat-30-90 degree.6-apfc relay microprossessor based-16 stage.7-acb used mdo 1.5g microprossessor based release uv., supply, instalation and commissioning with all bolts ,angle and supporting tool & takel with hardware as per requirerment of new aluminium bus bar grade- e91e with ducting, cap. 2,500 amp + 0.8 pf. all necessary conection will be done. make: hendalco
Tender For corrigendum : tender for supply of c18m260029 mto loading bay batch controller and flow meter for cpcl - mass flow meter coriolis ss316 3in 300 , digital control valve dcv , sov 2way normally close 20 watt ttl dcv , sov 2way normally open 20 watt ttl dcv , controller batch dl 6000 , earthing clamp w/pvc insul flexibl cable , earthing relay smart ground detector plus , installation & commissioning
Tender For corrigendum : supply of solenoid valve as per sl.no.1 of annexure_1 , solenoid coils as per sl.no.2 of annexure_1 , air lock relay as per sl.no.3 of annexure_1 , air filter regulator as per sl.no.4 of annexure_1 , limit switch as per sl.no.5 of annexure_1 , air operated valve as per sl.no.6 of annexure_1 , volume booster as per sl.no.7 of annexure_1 , smart positioner as per sl.no.8 of annexure_1
Tender For corrigendum : establishing 2x12.5 mva, 66/11kv sub-station at kalathmadu along with construction of proposed 66kv lilo line from the existing 66kv virajapete- ponnampete sc line on dc towers to proposed 66/11kv sub station at kalathmadu for a distance of 1.925km in virajpete taluk, kodagu district on partial turnkey basis including supply of all matching materials/equipments (excluding supply of 2x12.5mva 66/11kv power transformers and 11 kv switchgear) and erection (including civil works) of all materials/equipments, testing and commissioning - on load tap changer , control and relay panels, , circuit breakers, , 11kv mcvcbs & pcvcbs, , tower parts and all types of station structures with bolts, nuts and washers, , i beams & m.s channels, , lightning arrestors, , isolators, , insulators, , instrument transformers, , battery sets, , battery charger, , acsr conductors, , ground wire, , 11kv ug cable, , 1.1kv copper control cables & lt power cables, , capacitor bank, , hardware for insulator, conductor and ground wire:, , tension & suspension clamps and connectors., , accessories for conductor and ground wire:, , p.g clamps. m.s.c joints, pre-formed rods, repair sleeves, vibration damper etc., , c-type fire wedge connectors, , i) grounding materials (g.i flat, m.s flat etc.,), , il)grounding materials (c.i pipes), , ltac & dcdb panel, , 11kv termination & jointing kits, , class, , nitrogen injection fire protection, , system, , rigid tubular aluminium bus bars, aluminium clamps and connectors., , wave traps/line traps, , plcc equipment
Tender For corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission