Get complete information related to latest Relay Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Relay Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Relay Tenders.
Tender For corrigendum : maintenance of day to day complaints of water supply including connected items at various loc under ge nagrota - m&l for repair/rectification of leakage to water supply distribution lines 15 mm dia to 25 mm dia gi tubing by necessary excavation, returning/filling as required, tightening of loose joints of union, elbow, socket etc, threading if required including replacement of gi union/socket/nipple as required complete all as specified and directed., all as per srl item no.1 above but for gi tubing of 40 mm dia to 50 mm dia complete all as specified and directed., all as per srl item no.1 above but for gi tubing of 80 mm to 150 mm dia complete all as specified and directed., all as per srl item no.1 above but for gi tubing /di /ci /ms of 150 mm dia to 300 mm dia complete all as specified and directed. note : (i) the complaints for the above works shall be registered by contractor at the water supply complaint cell of age e/m (ii) stationary required such as complaint book, job cards etc shall be arranged by the contractor and proper record shall be maintained by the contractor.(iii) tools ,plumber with helper and transport with driver for attending of above complaints shall be arranged by contractor. (iv) the rate quoted by the contractor for above jobs under item no 1 to 4 shall be inclusive of cost of works under note (i) to (iii) above. (v) the said complaints shall be rectified within 12 hrs of the registration of the complaints failing which recovery of rs.500/commplaint shall be made for contractors due payment (vi) the stores/item required for the works under item no 1to 4 shall be measured separately under relevant item as supply only. (vii) excavation, returning/ filling shall be measured and paid for separately and material required for the works above shall be included to quoted rates., excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep including getting out in hard/dense soil complete all as specified and directed., returning /filling including watering , leveling , spreading and well ramming in layers not exceeding 25cm thick complete all as specified and directed., removing excavated material to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 50 metre above the starting point complete all as specified and directed., refixing/relaying of old retrieved steel tubing in new or old position with and including new gi fittings (connections) and as per site requiremen laid in trenches, above ground level or in any position of following sizes as under complete all as specified and directed : -, 15 mm dia, 20 mm dia, 25 mm dia, 40 mm dia, 50 mm dia, taking down unserviceable gi tubing / upvc tubing from any position complete with all fittings & connections from any position of following sizes as under complete all as specified and directed :-, 15 mm dia, 20 mm dia, 25 mm dia, 40 mm dia, 50 mm dia, supply and fixing/laying & testing of galvanised steel water tubing, medium grade, isi marked complete with all new galvanized fittings of following sizes laid in trenches/ above ground level or in any position complete all as specified and directed :, 15 mm dia, 20 mm dia, 25 mm dia, 40 mm dia, 50 mm dia, supply and laying upvc pipe tubings medium grade pressure rating 10 kgf/cm2 isi mark with all fittings such as elbow, bends, sockets, nipples and union etc and fixed complete laid in trenches or in any other position of following sizes as under complete all as specified and directed , 20 mm dia, 25 mm dia, 40 mm dia, 50 mm dia, supply only gi fittings, medium grade, isi marked of following sizes as under complete all as specified and directed :-, union 15 mm dia, union 20mm dia, union 25mm dia, union 32mm dia, union 40mm dia, union 50mm dia, socket 15 mm dia, socket 20 mm dia, socket 25 mm dia, socket 40 mm dia, socket 50 mm dia, reducer socket 40mmx50mm, reducer socket 15mmx20mm, reducer socket 20mmx25mm, elbow 15mm dia, elbow 20mm di
Tender For supply of e4963021 numerical relay 01-sg4950169246-numerical relay solution for annual rate contract flash protection system as per annexure-a it-01. uom-set,e4963021 numerical relay 01-sg4950169246-numerical relay solution for annual rate contract flash protection system as per annexure-a it-01. uom-set,e4963021 numerical relay 01-sg4950169246-numerical relay solution for annual rate contract flash protection system as per annexure-a it-01. uom-set,e4963021 numerical relay 01-sg4950169246-numerical relay solution for annual rate contract flash protection system as per annexure-a it-01. uom-set,e4963021 numerical relay 01-sg4950169246-numerical relay solution for annual rate contract flash protection system as per annexure-a it-01. uom-set,2-not to quote,2-not to quote,2-not to quote,2-not to quote,2-not to quote,3-not to quote,3-not to quote,3-not to quote,3-not to quote,3-not to quote,4-not to quote,4-not to quote,4-not to quote,4-not to quote,4-not to quote,5-not to quote,5-not to quote,5-not to quote,5-not to quote,5-not to quote
Tender For corrigendum : supply of breaker multiplication relay , lock out relay master trip relay , 220v dc under voltage relay , 220v dc over voltage relay , 220v dc earth fault relay
Tender For erection of 01 nos 33kv rewan bay with supply of material, integration and remote gateway work at 220kv ss bangra under etd jhansi - erection of following different type main and auxiliary structur, columns, beams, peaks, masts ets. suitable for placing of kv equipments., main structure & auxiliary structure., erection of following equipments as per instruction manual of various equipments and technical specification including shifting of material / equipments from sture to erection site including all other associated work to complete the job satisfactorily., 36kv v.c.b., 36kv bi, 36kv li, 36kv ct, ct junction box, cutting. strenghtening. bending. laying 700mm. below in side ground and above ground og following size of ms flat for earthing of main and auxiliary structure. equipment structure t/f body and its material etc. including welding with main earth mat and with object to be earthing / excavation of trenches its back filling., 75x10mm ms flat, 50x6mm ms flat, 25x10mm ms flat, provinig, fixing & installation of glow sign board (as per sample) of size 8ft x 6ft for updated substation single line diagram duly checked & verified by concerned ae, to be fixed in control room building of substation with all other associated work to complete the job satisfactorily as per drawing and technical specn. of upptcl, the glow sign board illumminated using led tube light in sufficient quantity. the board shall be made of acrylic sheet of suitable thickness and color and shall be provided with back support frame & fixing arrangement with wall., interconnection of equipments and bus bar including cutting. bending of conductor and jumping, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specn., equipment jumper with 1xmoose, 10mtr, 33kv, bus bar jumper with 1xmoose, 10mtr, 33 kv, 6m, laying of following sizes of control cable in the cable trench from control relay panel to various equipments / marshalling boxes and jb etc. in switchyard as per cable schedule., 2c x 2.5 sq mm. unarmoured., 4c x 2.5 sq mm. unarmoured., 6c x 2.5 sq mm. unarmoured., termination of 2cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 4cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 6cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., preparation of cable schedule and case interconnection diagram in between relevant panel,cb,ct,pt,etc.., providing and fixing of led street light luminaries, single piece aluminum body suitable for 120 watt having lumen output not less than 10,000 nom on 9 mtr. long stp/substation main structure column with g.1. pipe bracket complete in all respect cat. a philimps bajaj/ crompton/havells or equivalent make including cost of g.1. pipe brackets and all related accessories., supply, supply of single tension fitting suitable for acsr moose as per sample, supply of single suspension fitting suitable for acsr moose as per sample, supply of 33kv ct clamps suitable for acsr moose as per sample, supply of 36kv isolator jaw as per sample, supply of copper bond 16x500mm, supply of 33 kv isolator clamps suitable for acsr moose as per sample, intregration & remote gateway work, supply of required material with installation and intregration of new 33 kv line control & relay panel with iec -61850 compliant ied with existing automation system and addition of bay into remote gateway & data validation work.
Tender For erection of 01 nos 33 kv birdha bay with supply of material, integration and remote gateway work at 220kv ss birdha under etd jhansi - erection of following different type main and auxiliary structur, columns, beams, peaks, masts ets. suitable for placing of kv equipments., main structure & auxiliary structure., erection of following equipments as per instruction manual of various equipments and technical specification including shifting of material / equipments from sture to erection site including all other associated work to complete the job satisfactorily., 36kv v.c.b., 36kv bi, 36kv li, 36kv ct, ct junction box, cutting. strenghtening. bending. laying 700mm. below in side ground and above ground og following size of ms flat for earthing of main and auxiliary structure. equipment structure t/f body and its material etc. including welding with main earth mat and with object to be earthing / excavation of trenches its back filling., 75x10mm ms flat, 50x6mm ms flat, 25x10mm ms flat, provinig, fixing & installation of glow sign board (as per sample) of size 8ft x 6ft for updated substation single line diagram duly checked & verified by concerned ae, to be fixed in control room building of substation with all other associated work to complete the job satisfactorily as per drawing and technical specn. of upptcl, the glow sign board illumminated using led tube light in sufficient quantity. the board shall be made of acrylic sheet of suitable thickness and color and shall be provided with back support frame & fixing arrangement with wall., interconnection of equipments and bus bar including cutting. bending of conductor and jumping, clamping along with all other associated work to complete the job satisfactorily as per drawing and technical specn., equipment jumper with 1xmoose, 10mtr, 33kv, bus bar jumper with 1xmoose, 10mtr, 33 kv, 6m, laying of following sizes of control cable in the cable trench from control relay panel to various equipments / marshalling boxes and jb etc. in switchyard as per cable schedule., 2c x 2.5 sq mm. unarmoured., 4c x 2.5 sq mm. unarmoured., 6c x 2.5 sq mm. unarmoured., termination of 2cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 4cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., termination of 6cx2.5 sq.mm unarm.ctrl.cable at both end. as per cable schedule., preparation of cable schedule and case interconnection diagram in between relevant panel,cb,ct,pt,etc.., providing and fixing of led street light luminaries, single piece aluminum body suitable for 120 watt having lumen output not less than 10,000 nom on 9 mtr. long stp/substation main structure column with g.1. pipe bracket complete in all respect cat. a philimps bajaj/ crompton/havells or equivalent make including cost of g.1. pipe brackets and all related accessories., supply, supply of single tension fitting suitable for acsr moose as per sample, supply of single suspension fitting suitable for acsr moose as per sample, supply of 33kv ct clamps suitable for acsr moose as per sample, supply of 36kv isolator jaw as per sample, supply of copper bond 16x500mm, supply of 33 kv isolator clamps suitable for acsr moose as per sample, intregration & remote gateway work, supply of required material with installation and intregration of new 33 kv line control & relay panel with iec -61850 compliant ied with existing automation system and addition of bay into remote gateway & data validation work.
Tender For corrigendum : establishing 2x12.5 mva, 66/11kv sub-station at kalathmadu along with construction of proposed 66kv lilo line from the existing 66kv virajapete- ponnampete sc line on dc towers to proposed 66/11kv sub station at kalathmadu for a distance of 1.925km in virajpete taluk, kodagu district on partial turnkey basis including supply of all matching materials/equipments (excluding supply of 2x12.5mva 66/11kv power transformers and 11 kv switchgear) and erection (including civil works) of all materials/equipments, testing and commissioning - on load tap changer , control and relay panels, , circuit breakers, , 11kv mcvcbs & pcvcbs, , tower parts and all types of station structures with bolts, nuts and washers, , i beams & m.s channels, , lightning arrestors, , isolators, , insulators, , instrument transformers, , battery sets, , battery charger, , acsr conductors, , ground wire, , 11kv ug cable, , 1.1kv copper control cables & lt power cables, , capacitor bank, , hardware for insulator, conductor and ground wire:, , tension & suspension clamps and connectors., , accessories for conductor and ground wire:, , p.g clamps. m.s.c joints, pre-formed rods, repair sleeves, vibration damper etc., , c-type fire wedge connectors, , i) grounding materials (g.i flat, m.s flat etc.,), , il)grounding materials (c.i pipes), , ltac & dcdb panel, , 11kv termination & jointing kits, , class, , nitrogen injection fire protection, , system, , rigid tubular aluminium bus bars, aluminium clamps and connectors., , wave traps/line traps, , plcc equipment
Tender For design, manufacture, testing, supply (fixing & testing) and commissioning of 447nos of numerical relay (numerical over current and earth fault relay with over load protection) required for 11kv exclusive ip feeder breakers of various 66/11kv s/s coming under transmission (operations) mysuru zone. the numerical relay shall be fixed to respective 11kv exclusive ip feeder breakers by replacing existing over current & earth fault relays with suitable wiring / blanking plates.
Tender For corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission