Web Analytics Made Easy - StatCounter

Telephone Units And Mobile Phones Tenders

Get complete information related to latest Telephone Units And Mobile Phones Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Telephone Units And Mobile Phones Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Telephone Units And Mobile Phones Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :40135914 Due date: 19 May, 202519 May, 2025 17.50 Lacs
Tender For providing of customized amc/cmc for pre-owned products - annual repair contract of walkie talkie sets 1to 5 watts existing over delhi division and annual repair contract of 25 watts vhf sets psu existing over delhi division for three years; annual repair contra..

Central Government/Public Sector

CTN :40141657 Due date: 17 May, 202517 May, 2025 NA
Tender For supply of smart phones with min os android 14 support with ir sensor

State Government

CTN :40132709 Due date: 05 May, 202505 May, 2025 4.42 Lacs
Tender For dispose-off the under mentioned obsolete and unserviceable item on as is where is condition basis - laptop, mobile phone, mac pro workstation, apple led cinema display 27 -inch, laptop, desktop, rack server, laptop, desktop, desktop, server/sun computing node, ups, projector, desktop, printer, ups, projector, ups, photocopier machine, hhv pump, hhv pump, multimedia projector

corporations/Associations/Others

CTN :40025877 Due date: 03 May, 202503 May, 2025 NA
Tender For corrigendum : supply of boss secretary phone

corporations/Associations/Others

CTN :40126145 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

corporations/Associations/Others

CTN :40126147 Due date: 05 May, 202505 May, 2025 2.62 Lacs
Tender For 22/2025-26 purchase of laqshya instruments - purchase of instruments ( laqshay), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on ratchet. quick trendelenburg as well as reverse trendelenburg positions shall be provided with easily accessible operating handle provided with two gas springs for easy action. s.s. saline rod with 12 mm dia s.s

State Government

CTN :40139224 Due date: 20 May, 202520 May, 2025 NA
Tender For purchase of 3 ip phone in newly renovated digital & microprocessor lab

CTN :40119517 Due date: 15 May, 202515 May, 2025 NA
Tender For supply of canvas tripal 30 feet x 30 feet , electric wire 2 core 10mmn , electric wire casing , tonner richo mp 20114hs , cartridge pl h 2612a for canon lbp 2900b , ration account register as per sample , all out with machine , room freshner , cell bty , lizol , foot mat 2 feet x 2 feet , naphthalene ball , hand wash , spoon , cup , plate , fire extinguisher co2 4 point 5 kg , fire extinguisher water type 9 kg , fire extinguisher abc 9 kg , telephone set caller id phone with large led , garden pipe 1 point 5 inch , garden pipe half inch , spray gun machine with battery , morning parade state army civil register , master ledger of file

CTN :40134812 Due date: 16 May, 202516 May, 2025 NA
Tender For supply of cpu card for accord 600 , line card for accord 600 , mdf 150 pair , 50 pair dp box with krone module , 20 pair dp box with krone module , 10 pair dp box with krone module , fxo-8 port card for accord adx-600 n epabx , dcc card for accord adx-600 epabx , kcs 1 card , analog line card of neos epabx , fxs 16 card for adx 600n epabx , amplifier 200 watt bluetooth inbuilt two zone , party box hifi bluetooth speaker 310-240w , connection box cat 6 250 hz , console k2t4 357 accord 600 , power adapter 7vc2206 for cordless phone beetel , power adapter js 1201 12 v 2 amp for modem , testing phone , smps power plant for exchange , alcatel telephone set , sigle pair drop wire , fxo-fxs 16 port , fibre stripper wire cutter , amplifier to mobile connecting lead 15 mtr

CTN :40136861 Due date: 05 May, 202505 May, 2025 7.65 Crore
Tender For supply of software based solution for mobile phone forensic and photo recognizer
 Loading, Please wait...

Connect us via What's Up