Get complete information related to latest Busbar Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Busbar Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Busbar Scrap Tenders.
Tender For corrigendum : supply of supply installation testing and commissioning of 1600 kva 11 by 0.433 kv delta star step down as per atc attached , supply installation testing and commissioning of 11 kv 630a rated breaking capacity 21ka for 3sec sf6 insulated rmu as per atc attached , sitc of 2500 amps sandwich type bus trunking as per atc. , supplying and laying of 3 core 150 sqmm xlpe insulated cable on the existing cable tray or rcc or hume or metal pipe or susface as per atc attached , supplying and laying of 3 core 150 sqmm stranded aluminium conductor conductor screen with extruded semi conducting compound xlpe insulated cable in the existing masonary duct as per atc attached , supplying and makingoutdoor cable end termination with heat shrinkable joint for 3 core 150 sqmm 111 kv grdae as per atc attched. , copper plate earthing complete as per atc attached. , gi plate earthing complete as per atc attached. , providing 50 mm and 5 mm thick copper strip on surface as per atc attached. , providing 25 mm and 5 mm thick copper strip in 40 mm gi pipe as per atc attached. , providing 25 mm and 5 mm thick copper strip on surface as per atc attached. , supplying and laying of 80 mm gi pipe a-class on surface as per atc attached. , supplying and laying of 80 mm gi pipe a-class in ground as per atc attached. , supplying and laying 120 mm dia dwc hdpe pipe as per atc attached. , supply and installation of 4.5 kg co2 type fire extinguisher isi marked as per atc attached. , supply and installation of 06 kgs abs powder type fire extinguishers as per atc attached. , supply and installation of 3 mm thick rubber mat suitable for 33 kv as per atc attached. , supply and installation 0f 4 nos 9.5 ltrs capacity gi bucket as per atc attached. , supply and installation of first aid box as per atc attached. , supply and fixing safety instruction chart as per atc attached. , supply and fixing shock treatment chart as per atc attached. , supplying and fixing of 40mm x 40mm x 5mm thick angle iron frame complete as per atc attached. , supplying and fixing of single line diagram and layout diagram complete as per atc attached.
Tender For spl repair/replacement of lt ug cables from main power house/new power house to p-1 building alongwith bus trunking system inside vijay durg unge ge(vd) kolkata
Tender For design, supply, installation, commissioning and testing of 250a sandwich type bus bar trunking (rising mains) with 2 runs of 25 x 6 mm copper/ aluminum earthing at electric locomotive shed, tughlakabad, new delhi-44.
Tender For bid to ras corrigendum : supply of 750 amp aluminium busbar chamber , 630 a 50 mm x 5 mm copper busbar , 1000 amp 4 strip aluminium busbar , ms angle iron bracket of size 50 x 50 x 5 mm , laying of cable above 185 sq mm and upto 400 sq mm , laying of cable above 95 sq mm and upto 185 sq mm , laying of cable above 35 sq mm and upto 95 sq mm ms flat clamp , cable end termination 3 core x 240 sq mm , cable end termination 3 core x 185 sq mm , cable end termination 3 core x 120 sq mm , cable end termination 3 core x 70 sq mm , cable end termination 3 core x 400 sq mm , 3 core x 400 sq mm straight through joint with heat shrinkable kit , checking testing of burnt out 2 nos 400 sq mm cable , checking testing of 800 amp 4 pole change over switch , testing and megaring of 2 nos unutilised 400 sq mm cable , testing and megaring jointing of up to 50 sq mm cable , 6 swg dia gi wire , dismantling and relaying of various size cable , dismantling the existing main mv panel and bus trunking , dismantling of existing 33 kv relay panel , transportation loading unloading of cable drum , spray painting of 500 kva transformer ) /bid number : gem/2026/b/7235217 * /dated: 13-02-2026 & & / bid document 1 / 25
Tender For procurement of jigs and fixtures as per drawing from hal registered vendors - end cover as per bhel drg no 26992190049 rev 05 varno00 , end cover as per bhel drg no 26992190049 rev no 05 varno 001 , molded panel rear side as per bhel drg no 36992190024 rev no 03 item no 001 var no 00 , topslashbottem front panel as per bhel drgno 36992190021 rev no 03 item no 001 var no 00 , topslashbottem front panel as per bhel drgno 36992190021 revno 03 item no 002 var no 00 , end covertopslashbottem dc bus bar side as per bhel drgno 36992190020 rev no 03 item no 001 var no 00 , end cover topslashbottem cooling as per bheldrgno 36992190020 revno 03 item no 002 var no 00 , end cover topslashbottem drgno as per bhel 36992190020 rev no 03 item no 003 var no 00 , middle front panel with cutout as per bheldrgno 26992190147 rev no 02 var no 00 , middle front panel with out cutout as per bhel drg no 26992190147 rev no 02 var no 01 , gland plant heat exchanger as per bhel drgno 46500300036 rev no 02 var no 00 , blanking plate as per bhel drgno 46500300034 rev no 01 var no 00 , duct support rectifier as per bhel drgno 46992190014 rev no 02 var no 00 , trunking details rh and lh drgno 46500900046 rev no 01 var no 00 , trunking details top and bottem as per bhel drg no 46500900047 revno 02 var no 00 , gland plate as per bhel drgno 46500700001 revno 02 var no 00 , fibre glass header tank as per 36500600024 rev03 , insulation sleeveto as per bhel drgno 46992190011 rev02 , insulating stud to as per bhel drg no46500300027 rev 03 , stack support to drgno 46500300037 rev03 item 1 , stack support drg no 46500300037 rev03 item2 , stack support to drg no46500300037 rev03 item03 , toughened glass to drg 46500300032 rev02 , phase barrier to drg 36500300104 it01 rev no 01 , nylon braided pvc hose sl25 id25mm od35mm , nylon braided pvc hose sl010 id10mm od16mm , ss304 klipco tightening clip 28mm od
Tender For supply of insulated bar - end cover as per bhel drg no 26992190049 rev 05 varno00 , end cover as per bhel drg no 26992190049 rev no 05 varno 001 , molded panel rear side as per bhel drg no 36992190024 rev no 03 item no 001 var no 00 , topslashbottem front panel as per bhel drgno 36992190021 rev no 03 item no 001 var no 00 , topslashbottem front panel as per bhel drgno 36992190021 revno 03 item no 002 var no 00 , end covertopslashbottem dc bus bar side as per bhel drgno 36992190020 rev no 03 item no 001 var no 00 , end cover topslashbottem cooling as per bheldrgno 36992190020 revno 03 item no 002 var no 00 , end cover topslashbottem drgno as per bhel 36992190020 rev no 03 item no 003 var no 00 , middle front panel with cutout as per bheldrgno 26992190147 rev no 02 var no 00 , middle front panel with out cutout as per bhel drg no 26992190147 rev no 02 var no 01 , gland plant heat exchanger as per bhel drgno 46500300036 rev no 02 var no 00 , blanking plate as per bhel drgno 46500300034 rev no 01 var no 00 , duct support rectifier as per bhel drgno 46992190014 rev no 02 var no 00 , trunking details rh and lh drgno 46500900046 rev no 01 var no 00 , trunking details top and bottem as per bhel drg no 46500900047 revno 02 var no 00 , gland plate as per bhel drgno 46500700001 revno 02 var no 00 , fibre glass header tank as per 36500600024 rev03 , insulation sleeveto as per bhel drgno 46992190011 rev02 , insulating stud to as per bhel drg no46500300027 rev 03 , stack support to drgno 46500300037 rev03 item 1 , stack support drg no 46500300037 rev03 item2 , stack support to drg no46500300037 rev03 item03 , toughened glass to drg 46500300032 rev02 , phase barrier to drg 36500300104 it01 rev no 01 , nylon braided pvc hose sl25 id25mm od35mm , nylon braided pvc hose sl010 id10mm od16mm , ss304 klipco tightening clip 28mm od
Tender For corrigendum : replacement of lbt (lighting bus trunking) and associated electrical work over l-1. - “replacement of lbt (lighting bus trunking) and associated electrical work over l-1”
Tender For corrigendum : repairs to distribution transformer bus trunking system sf6 circuit breaker current transformers voltage stabilizers battery banks and certain control cables and switch gears at rci hyderabad - repairs to distribution transformer, bus trunking system, sf6 circuit breaker, current transformers, voltage stabilizers, battery banks and certain control cables and switch gears at rci hyderabad