Get complete information related to latest Busbar Scrap Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Busbar Scrap Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Busbar Scrap Tenders.
Tender For procurement of spares of mineline private limited make flp vcb 3 3kv flp tsu 3 3kv 550v flp acb etc - isolator 400a , vacuum circuit breaker 3.3kv , potential transformer 3.3 kv , hrc ht pt fuse , primary side p.t fuse plate wiring assembly , h.t. control plate wiring assembly , voltmeter , fuse terminal , multicore bushing , indicating lamp , 3.3kv adopter , 3.3kv coupler , bullet pin 3.3kv , hv bushing , dc power pack , neutral monitoring relay with resistance , earth leakage 50 750m a and 750ma 2a dual settings , earth leakage relay 50 750m a with time lag with cbct , overload short circuit and motor protection relay , vcb aux .rotary switch , control relay , ht bushing , vcb shunt trip coil , timer , 3 pole oil dashpot relay , cover bolts , insulator assembly k3 on off , overload assembly breaker 110a 200a , overload assembly breaker 310a 400a , overload coil 200a , short trip assembly complete , shunt trip coils , no volt coil assy. under voltage coil assy. with moulding , catcher assembly , arc chutes , ammeter 200 5 for acb , ammeter 100 5 for acb , ammeter 300 5 for acb , ammeter 400 5 for acb , busbar , potential transformer , brass cone and gland assembly , indicating lamps , power cable for 300a for breaker chamber ic and og , limit switch 2no 2nc for breaker , brass terminal for cp , brass terminal with dmc insulator , terminal bushing insulator dmc incoming 10mmx25mm , on off isolator 300a , split type terminal box , on off isolator 400a , circuit breaker for 100a with complete assy. , circuit breaker for 200a with complete assy. , complete control wiring including pla relay ptds elm7 control fuses control plate wiring harness etc mounted on control plate or circuit breaker for 300a with complete assy , complete control wiring including pla relay ptds elm7 control fuses control plate wiring harness etc mounted on control plate or circuit breaker for 400a with complete assy , earth leakage 50 750m a with time lag , core balance transformer , on off isolator 100a , isolator handle , 1ph 5kva lighting transformer 550 440v sec.110v with mid point earthed , earth leakage relay , brass terminal with dmc bushing , brass stud with dmc bushing for og , magnetic ol relay , thermal ol relay , on delay timer , push button and element , isolator on off rev 100a , pilot relay , switch module , isolator on off rev 200a , on off rev isolator 300a , copper terminal bushing cp og , aux. contactor 220v ac , resistance
Tender For repair /replacement of unsv outdoor busbar chamber, repair of faulty ht 11 kv cable alongwith connected items at cpg, dgncc area under aor of age (sldc) e/s under ge (u) e/s delhi cantt-10
Tender For corrigendum : providing and installation of electrical accessories and allieds works at shaspur pwss, block-rampurhat-ii under bolpur mechanical division - supply, delivery at site and storage of wall mounted made of sheet steel fabricated 2 mm for load bearing & 1.6mm for non load bearing, indoor type, dust & vermin proof, lp-54 degree of protection, powder coated painted with rubber gaskets cover, front lockable hinged door with all switchgear and other items duly wired up and tested as per specification: incomer: (a) 100 amps, tpn mccb with adjustable ol, 36 ka, e/f, auto phase corrector & necessary accessories with suitable spd (i.e., ammeter, voltmeter, cts & switches), outgoing:- (b) 7.5 hp to 12.5 hp, tp star-delta starter with other accessories - 1 nos., (suitable size capacitor bank to improve pf from o.85 to 0.98) (c) yard lighting feeder with necessary accessories & time switch(digital) - 1 no. (d) 3phase actuator valve starter with other accessories -1 nos., (e) 2 hp ,3 ph,415v,clorinator feeder with necessary accessories & level controller-1 no., (f) 32a mccb fdr for iep/misc purpose-1no., (g) 32a mccb for in house light-1no.,(e) plc feeder with necessary accessories-1no.( all spare & components as per vendor list of phed), supply and delivery at site of 15 kva, 3phase, oil cooled type servo motor operated copper wound line voltage corrector conforming to is-9815 (pt.-1)- 1994 suitable for un-balanced input voltage with following specification including first filling oil as per is-335 where applicable.a) input voltage:- 3 phase, main supply may or may not be balanced with respect to phase to phase- 200v-500v phase to neutral-115v-290v.b) output voltage:-3 phase balanced output voltage. phase to phase- 400vor 415v 1%, phase to neutral- 230v-240v 1% (provision should be made to adjust the variation of output voltage per phase by a variable pot oil within 5% of output).c) line regulation:- out put voltage should remain well with 1% of set voltage (from minimum to maximum i.e. either 400v. or 415v. supply variation).d) load regulation : output voltage should remain neutral well within 1% of set voltage be ( from no load to full load ) i.e. either 400v. or 415v.e) correction speed:- better than 35 volt / second.f) efficiency:- better than 95% on full load.g) cut off limit (minimum &maximum ) by limit switch with audio & visual.h) metering indication:- by selector switch provision should be made available to measure input mains supply and output voltage other stabilizer for load current measurement an ammeter with selector switch should be available.i) lamp indication :- for input & output should be provided. ( 3 lamps per side ).j) mcb protection: for input side.k) load protection : hrc fuse on each output phase should be availablel) output over shoot:- beyond 210v to . 255v /phase in case of manual mode & voltage protection :auto mode operation.m) visual indication for under voltage & over voltage of output.n) manual mode:- up & down correction with o / p voltage over shoot protection. beyond 210 v-255 v. per phase.o) nature of cooling:- oil cooled system.p) electric current over load protection .q) circuit for delay output .r) input high voltage cut-off above 500 v.s) mode of operation:- auto/manual with a provision to restore the normal working of the unit standby operation should be available in case of any electronic failure in auto mode., installation of mcc panel along with main switch, changeover, busbar chamber, cut out etc. all electrical equipment within the pump house, drawing of cable properly on suitable size gi cable tray on wall / as per direction of eic as per layout & ie rules and all connection with supply necessary materials, cable etc to complete the work, making arrangement with supply & fixing of materials for taking power within the pump house from wbsedcl end as per direction of eic. [for ph no - i, ii & iii], installation of above
Tender For corrigendum : providing and installation of electro-mechanical accessories at cwr site and allieds works at ekpara pwss, block-rampurhat-i under bolpur mechanical division - supply and delivery of openwell submersible pumping machinery set suitable for wet pit installation complete with stainer along with all accessories with following specification: pump : discharge (q) : (1800-1280) m3/hr. & head (h) : (19-38) mtrs.method of starting : sd, shaft-stainless steel-ss-304, impeller- crome steel/ci/s.s / bronze, suc & del size- 90/80 mm dia, type of position-horizontal. mechanical sealmotor : 12.5hp (suitable for open well)operating voltage : 415 ( 10 %), phase : 3ph, 50 hz 6%speed : 2800 rpm, method of starting : s/dmake : ksb / grundfos / texmo / cri / kbl / mbh / or any approved vendor. ( n.b : manufacturers test certificate along with charecteristics curve, moc and gurantee certyificate have to be submitted at the time of delivery.), supply & delivery at site of 35 mm x 3.5 core size aluminum armored, xlpe insulated 1.1 k.v. grade cable, conforming to is 7098(i) as per direction of eic.(make:- gloster / polycab / mescab / or any approved vendor list of phed.) ( n.b : manufacturers test certificate have to be submitted at the time of delivery.), supply & delivery of 100a kit-kat rewireable (porcelain fuse carrier & base) (make:- havells / l&t / or any approved vendor list of phed.), supply & delivery of 100 amps re-wireable porcelain fuse unit type tpn main switch with steel sheet enclosure (conforms: is/iec600947-1&3). (make: havells /approved vendor list of phed.), supply & delivery of re-wireable type tpn changeover switch 100 amps 415v, 50hz, 4 pole offload with steel sheet enclosure (conforms: is/iec60947-1&3). (make: havells /approved vendor list of phed.), 100 amps, 4way, wall mounted copper busbar chamber with steel sheet enclosure (conforms:is/iec:60947-3). (make: havells /approved vendor list of phed.), supply and delivery of the following pipes, valves, pipes and gauges etc at site-- (make: approved vendor list of phed.), 100mm dia m.s. black pipe p/e conforming to is:1239 part-1 (2004), heavy (c class)., 150mm dia m.s. black pipe p/e conforming to is:1239 part-1 (2004), heavy (c class)., 100mm dia m.s. blank flange 15mm thick perforated as per is1538., heavy type suitable dia. ms suspension clamp along with nuts bolts and washers., 100mm dia. cast iron double flanged manually operated rising spindle type sluice valve generally conforming to is: 14846, having body, door, dome / bonnet, gland in graded cast iron to is 210 gr. fg 260, four faces of ss aisi 304 and spindle nut of gunmetal to is 318 gr. ltb 2, outside screw rising stainless steel aisi 304 spindle, valves suitable for a maximum working pressure of 10 kg/cm (seat test) & body tested to 15 kg/cm . flanges faced and drilled to is:1538 table 4 & 6. valves tested by closed end method only. (moc & tc needed for valve)., 100mm dia. cast iron double flanged single door swing non-return valve generally conforming to is:5312 part i, having body, door, cover in graded cast iron to is 210 gr. fg 260; body & door rings of stainless steel to ss aisi 304 , hinge pin of ss aisi 304, valves suitable for a maximum working pressure of 10 kg/cm (seat test) & body tested to 15 kg/cm . flanges drilled to is 1538 table 4 & 6.(moc & tc needed for valve)., 100 mm dia dismantling joint pn-1.0 ci dismantling joint complete galvanised , stud, nut and washer and follower flanges, drilled to is:1538 table 4 & 6. ( at delivery side of pump ), supply & fixing of perforated gi cable tray tee with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. s&f gi connector, 6mm dia ms suspender, bolts & nuts, steel fastener etc. as required of the following size. incl. al painting of ms support. [200x50x1.25mm x 3mtr long
Tender For supply of split air conditioner including green ac, wall mount type (v2) (q2) , supply of 11 kv, 800 amps ht vacuum circuit breaker bus coupler, indoor panel conforming to iec 62271, 200, 25 ka for 3 sec, all as mentioned in specification and as directed , installation, testing and commissioning of 11 kv, 800 amps, ht vacuum circuit breaker, bus coupler indoor panel , supply of ht bus trunking chamber adopter panel of capacity 12 kv 800 amp or nearest higher rating bus bar totally sheet metal enclosed matching with ht panel including busbar , installation, testing and commissioning of ht bus trunking chamber adopter panel of capacity 12 kv 800 amp , shifting of existing 8 nos vcb for installing of bus coupler between existing vcb and connect the bus coupler complete