Web Analytics Made Easy - StatCounter

Cable End Box Tenders

Get complete information related to latest Cable End Box Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable End Box Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable End Box Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45048307 Due date: 31 Jul, 202631 Jul, 2026 NA
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp

CTN :45591042 Due date: 27 Jun, 202627 Jun, 2026 NA
Tender For supply of sluice valve 200mm pn1 point 6 isi marked , sluice valve 150mm pn 1 point 6 isi marked , pump starter 12 point 5 hp delta isi marked , ht tape 3m 19mmx9mtr , ht tape 3m 25mm x 10mtr roll , non return valve 150mm isi marked , led garden light 10w , sluice valve 100mm pn 1 point 6 isi marked , led bulb 7 watts , cable copper pvc frlsh 2 point 5 sqmm multistranded single core , sluice valve 80mm pn 1 point 6 isi marked , sensor based led tube light batten 20w , heating element 1500 watt triangular type , non return valve 100mm isi marked , heating element 2000 watt triangular type , ht cable end box outdoor 3 c x 95 sqmm 11 kv e , led driver for 2 feet x 2feet false ceiling light fitting , ht cable end box indoor 3 c x 95 sqmm 11 kv e , heat strinks joint kit indoor 3c x 95 sqmm , cable copper frlsh pvc 1 point 5 sqmm multi stranded single core , submursible cu cable 16 sqmm x3core isi marked , submursible cu cable 25 sqmm x3core isi marked , sheet metal enclosure with plug top and mcb sp 20a , pvc flexible cable frlsh 0 point 5 sqm three core , pvc flexible cable 23 oblique 00076 twin core , led tube rod 20w essential 1200mm 2100 lm , thermostat for geyser 25 ltr , led electronic driver 150 w , led electronic driver 100 w , fan regulator switch type , mcb 63 amp 4 pole isolator , pvc flexible cable frlsh 1 point 5 sqm three core isi marked , mcb 40 amp 4 pole isolator , cable copper frlsh 1sqmm single core isi marked , mcb 32 amp 4 pole isolator , led electronic driver 45 w isi mrked , thermostat for geyser 50 ltr isi marked , 20amp plug and socket distribution board , modular socket with mcb sp 25a , regulator electronic for ceiling fan modular type , fan regulator dimmer 400 oblique 450w , switch socket combination 6a , led driver 90w , led electronic driver 72 w , mcb sp 06 amp 230 volts 10 ka , led tube light fitting 20 w alum extruded decorative box with driver and tubelight , led bulb 9 w 230 volt with electric backup battery , led tube light fitting 18 w alum extruded decorative box with driver and tubelight //bid details 2 / 136

CTN :45549158 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For distribution transformer of rating 500 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, on load type tap changer for variation of hv voltage from +5% to -15% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, confirming to is 1180 (part 1): 2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4 nos.) shall confirm to is 7421. suitable cable-end box along with cable entry hole glands is tobe provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is 1180 (part 1) latest. (ii) routine test certificates as per is: 1180(part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d), (e) of is: 1180 (part 1) latest. bee star rating:- 3 or above (firm shall submit a valid bee certificate for the offered product with desired bee star rating). [ warranty period: 30 months after the date of delivery ] ]

State Government

CTN :45491313 Due date: 18 Jun, 202618 Jun, 2026 2.00 Lacs
Tender For चिकित्सालय में बिजली उपकरण एंव पलम्बर कार्य हेतु - for electrical equipment and plumber work in hospital. - 24"ceiling fan , 36"ceiling fan , 48"ceiling fan , ceiling fan winding copper , 12"cooler winding copper , 16"cooler winding copper , 18"cooler winding copper , 9"exhaust fan winding , 12"exhaust fan winding copper , 16"exhaust fan winding copper , 18"exhaust fan winding copper , ceiling fan bearing nbc , cooler motor bus bearing and shaft , 9"exhaust fan copper , 12"exhaust fan copper , 18"exhaust fan copper , 12"cooler motor , 18"cooler motor 1" , 18"cooler motor 2" , 12"cooler motor copper , 18"cooler motor copper , cooler motor capacitor , ceiling fan capacitor , 10 letters geyser , 15 letters geyser , 20 letters geyser , 25 letters geyser , mcb-6a,8a, 10a , mcb-16a,25a , mcb-32a , mcb-63a , modular switch-6a , modular switch-16a , simple switch-6a , simple switch-10a , modular switch-25a , two pin top 6a , two pin top 16a , 3 pin top 6a , 3 pin top 16a , modular sockets 6a , modular sockets 16a , simple sockets 6a , simple sockets 16a , led lamp 7w , led lamp 9w , led lamp 12w , led lamp 15w , led lamp 18w , led lamp 23w , led lamp 50w , led lamp 100w , led lamp 200w , led tube light 20w , led tube light 40w , led tube light 60w , ceiling fan regulator dimer type , ceiling fan regulator dimer type , electric tap roll , electric tap roll big , tubelight holder , fluorescent tube , led fluorescent tube 20w , led fluorescent tube 40w , tubelight chokes , ro smps charger , ro filter , ro membrane gold , water pump starter repairing service charge generator repairing service charge , 0.50 squ.mm,0.75squ.mm copper wire , 1squ.mm,1.5sq.mm copper wire , 2squr.mm, 4squr.mm copper wire , समिति 6sq.mm,8,12,16sq.mm copper wire सीकर 'lugs - 4mm,6mm,8mm,16mm , 100/5 contact bar , water pump starter repairing service charge , generator repairing service charge , labour service charge , technician service charge , plumber service charge , ro service , ceiling fan service charge , tubelight service charge , cpvc pipe ½" , cpvc pipe 1" , cpvc pipe 1½" , pvc pipe 2" , pvc pipe 2½" , pvc pipe 4" , 90° elbow , cpvc tee brass 1/2" , cpvc tee1/2" , cpvc coupler ½" , cpvc mt brass ½" , cpvc mt ½" , cpvc mt 1" , cpvc ft brass ½" , cpvc ft ½" , cpvc joint ½" , cpvc end cap ½" , cpvc tank nipple ½" , pillar bib cock ss , bib cock long ss , angle cock , sink cock , water tank football

Central Government/Public Sector

CTN :45498664 Due date: 01 Jul, 202601 Jul, 2026 2.54 Lacs
Tender For tender for supply of electrical items - bearing deep groove 6206zz skf sbl 206 dd , lock pad harrison 70 mm , capacitor 2 5 mfd x 440v , switch piano type made of tough non ignitable moulded insulating material , switsh tumbler single pole way quick make and brake cover and base of tough , plug top three pin of tough non-ignitable insulating mate- rial with bronze pins , plug top three pin of tough non-ignitable insulating mate rial with bronze pins , switch tumber two pole way quick make and brake cover and base of tough , three pin socket surface type non shutterd cover of tough non ignitable material , three pin socket surface type non shutterd cover of tough non ignitable material , heater element rod 10 inch 1000 watt , pvc fine adhesive tape suitabl for l t insulation , starter tube light glow lamp t with radio interferance suppre ssing capacitor brass , starter tube light glow lamp t with radio interferance suppre ssing capacitor , 36 40 watt fluorescent tubular discharge lamp suitable , hydrometer 1100 1300 range , araldite in 180 gm tube , m seal c j compound n type , gls incandescent lamp coiled filament in clear finish bayonet cap , high speed steel hack saw blade , spring contact assy , spring for pomel contact in loco battery , sand paper fine , brass pendant lamp holder b c type with shade carrier ring , hack saw frame chromium plated tubler , de electrical padlock with nylon shackle key , tags made of white special grade pvc sheet , bag canvas for tools , electrical screw driver insulated cellulose plastic handle confi reming to is 844 1979 5 x200 mm product 937 i make taparia , double end open spanner set of twelve pieces , pin slide wrench , double end ring spanner chrom vanadium steel chrom plated , plier combination insulated 8 inch 200 mm , grinding wheel for hitachi disc grinder model , 1 2 square drive socket set complete ranging f , two way rotary switch two pole 911213

CTN :45479514 Due date: 25 Jun, 202625 Jun, 2026 NA
Tender For distribution transformer of rating 250 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, the type of tap changer: off-load tap changer for variation of hv voltage from +5% to -10% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, conforming to is 1180 (part 1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest withcondition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall conform to is/iec 60137. the low voltage bushings (4 nos.) shall conform to is 7421. suitable cable-end box along with cable entry hole glands is to be provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates as per is: 1180 (part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is: 1180 (part 1) latest. detailed specification attached as annexure a. [ warranty period: 30 months after the date of delivery ]]

CTN :45470987 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For supply & testing of 500 kva, 11kv/750v, 3-phase, 50 hz. outdoor type power transformer conforming to 15 2026 (part 1): 2011 (reaffirmed 2021), plinth mounted, copper wound, mineral oil immersed with freely breathing system (also called conservator system) as per clause 8.2 (a) of is 2026 (part 1), primary winding in delta and secondary winding in star (vector symbol-dyn11), onan cooled transformer, minimum short circuit impedance of 5% as per is 2026 (part 5), with all fittings specified in annexure a to this description, terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4) nos.) shall conform to 15.7421. suitable cable-end box is to be provided as follows: a) for outdoor type: l.t. side tap changer: on-load tap changerfor variation of hv voltage from -+5% to -5% in steps of 1.25% make- andrew yule/aeg/crompton greaves/kirloskar electric co./abb/siemens/schneider or similar. [ warranty period: 30 months after the date of delivery ] ]

CTN :45117105 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For distribution transformer of rating 500 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, the type of tap changer for variation of hv voltage from +5% to -15% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, confirming to is 1180 (part 1): 2014with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 of is 1180 (part 1). terminal agreement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4 nos.) shall confirm to is 7421. suitable cable-end box along with cable entry hole glands is to beprovided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is 1180 (part 1) latest. (ii) routine test certificates as per is: 1180(part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d), (e) of is: 1180 (part 1) latest. [ warranty period: 30 months after the date of delivery ]

CTN :45099179 Due date: 27 May, 202627 May, 2026 NA
Tender For supply of thermometer digree , series test lamp , knife switch dpdt fuse terminals , knife switch tpdt fuse terminals , miniature circuit breaker mcb , earth plate copper , earth plate , earth electrode copper , mccb , elcb , rccb , fuse hrc type , fuse glass type , fuse rewire type , rheostat sliding type 0 to 25 2a , rheostat sliding type 0 to 300 2a , rheostat sliding type 0 to 1 10a , rheostat sliding type 0 to 10 5a , capacitor electrolytic type , capacitor ceramic type , capacitor polyester film type , capacitor variable type , capacitor dual run type , lamp halogen incandescent type , lamp fluorescent tube type , hp lamp mercury vapour , hp lamp sodium vapour , lp lamp sodium vapour , lamp led , plug socket piano switch lamp holder , cables , bus bar brackets , rubber mat thick , electrician helmet , rcc pole accessories lt line , safety belt , ohm meter series type , ohm meter shunt type , digital multimeter , voltmeter multirange , milli voltmeter centre zero , ammeter mc ma portable lab type , ammeter mc portable lab type 0 to 5 a , ammeter mc portable lab type 0 to 25 a , ammeter mi portable lab type 0 to 1 a , ammeter mi portable lab type 0 to 5 a , ammeter mi portable lab type 0 to 25 a , kw meter analog , digital wattmeter , energy meter single phase , energy meter three phase , three phase power factor meter digital , frequency meter , magnetic flux meter , lux meter , tachometer analog , digital tachometer photo sensor , tong tester clamp meter digital , megger , 3 point starter , 4 point starter , wheatstone bridge galvanometer battery , single phase variable auto transformer , phase sequence indicator , growler , resistance type starter , direct on line dol starter , star delta starter manual , star delta starter semi automatic , star delta starter fully automatic , soft starter 3 phase , auto transformer type starter , oscilloscope dual trace , function generator , soldering iron 25w , soldering iron 65w , soldering iron 120w , temperature controlled soldering iron , discrete component trainer , linear ic trainer , digital ic trainer , electric hot plate induction type , electric kettle , electric iron , immersion heater , ceiling and table fan , geyser storage type , mixer and grinder , washing machine , motor pump set 1 hp , oil testing kit , inverter input output battery , voltage stabilizer input output , power supply , battery charger , current transformer , potential transformer , solar panel battery , computer system , laser printer , manual motor coil winding machine step arbor , ceiling fan coil winding machine , primary current injection set , smart meter single phase , smart meter three phase , ev charger 3 phase , ev charger home single phase , working bench , wiring board projection , instructors table , instructors chair , metal rack , lockers drawers , almirah , black board white board , fire extinguisher , fire buckets , turnkey execution of electrician lab setup measuring steel tape- specification not available, combination plier insulated 200 mm- specification not available, screw driver 4150 mm diamond head- specification not available, screw driver insulated 6150 mm- specification not available, electrician screw driver - specification not available, heavy duty screw driver insulated- specification not available, electrician screw driver- specification not available, punch centre- specification not available, knife double bladed electrician - specification not available, neon tester 500 volt- specification not available, steel rule 300 mm (metric & english)- specification not available, hammer cross peen 250 gm- specification not available, hammer ball peen 500 //bid details 2 / 130 gm- specification not available, pincer 150 mm- specification not available, clamp 'c' 100 mm- specification not available, clamp 'c' 200 mm- specification not available, spanner 150 mm adjustable drop forged ss- specification not available, spanner 300 mm adjustable drop forged ss- specification not avail

CTN :44948129 Due date: 20 May, 202620 May, 2026 NA
Tender For supply & testing of 500 kva, 11kv/750v, 3-phase, 50 hz. outdoor type power transformer conforming to 15 2026 (part 1): 2011 (reaffirmed 2021), plinth mounted, copper wound, mineral oil immersed with freely breathing system (also called conservator system) as per clause 8.2 (a) of is 2026 (part 1), primary winding in delta and secondary winding in star (vector symbol-dyn11), onan cooled transformer, minimum short circuit impedance of 5% as per is 2026 (part 5), with all fittings specified in annexure a to this description, terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4) nos.) shall conform to 15.7421. suitable cable-end box is to be provided as follows: a) for outdoor type: l.t. side tap changer: on-load tap changerfor variation of hv voltage from -+5% to -5% in steps of 1.25% make- andrew yule/aeg/crompton greaves/kirloskar electric co./abb/siemens/schneider or similar. [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up