Tender For supply of srphc82278027-crt- p pulse generator for delivery of cardiacresynchronizationtherapy. system should include a current generation crt pulse generator compatible with bipolar steroid-eluting atrial and ventricular leads and a biploar left ventricular lead (coronary sinus ). should provide independently programmable right and left ventricular pulse outputs and interventricular delay ( with the choices of right ventricular alone, leftventricular alone or biventricular pacing as well as the choice of which ventricle is to bepaced first with optimization of delay for pacing of other ventricle ). should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrialtachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch, ventricular rate management etc., pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimal features for introduction, positioning and fixation and documented low displacement rates. safety and efficacy of the system should be well documented. unit: number. ]
Tender For supply of disposable flexible ureterorenoscope chip on tip technology with coms 3 point 6fr working channel deflection 270 degress up to down , slimline 365micron blue jacket resuable fiber maximum outer dia 0point 58mm 1point75f working channe , slimline 550 micron blue jacket resuable fiber,each maximum outer dia 0 point 78 mm 2 point 25 f working channel needed 1point 0 mm 3 point 0 f part no 0624 149 55 lumenis , slimline 200micro blue jacket reusable fiber maximum diameter 0 point45 mm 1point35 working channek needed 0 point6mm 1point 8f for flexible uretero renoscopy , tipless nitinol stone reterival basket 2 point 2 fr , bta stat test kit of 10 , ureteroscopy irrication system ref 05035099 path finder , urostomy kit complete consisting of 10flange plus 10pouch plus 1belt plus 1paste plus 1 powder 55 mm , disposable flexible cystoscope with accessories forceps and y connector
Tender For supply of srphc82278027-crt- p pulse generator for delivery of cardiacresynchronizationtherapy. system should include a current generation crt pulse generator compatible with bipolar steroid-eluting atrial and ventricular leads and a biploar left ventricular lead (coronary sinus ). should provide independently programmable right and left ventricular pulse outputs and interventricular delay ( with the choices of right ventricular alone, leftventricular alone or biventricular pacing as well as the choice of which ventricle is to bepaced first with optimization of delay for pacing of other ventricle ). should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrialtachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch, ventricular rate management etc., pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimal features for introduction, positioning and fixation and documented low displacement rates. safety and efficacy of the system should be well documented. unit: number. ]