Tender For corrigendum : procurement of medical equipment for mmch (package 1) - supply, installation,testing and commissioning of mri 3 tesla(along with associated works, accessories and allied items as specified), supply, installation,testing and commissioning of biplane dsa system with large flat panel detector with inbuilt angiography and intervention and stereotactic radiotherapy (along with associated works, accessories and allied items as specified), supply, installation,testing and commissioning of 256-slice dual energy spectral high end ct scanner (along with associated works, accessories and allied items as specified), supply, installation,testing and commissioning of 64 slice ct scan machine(along with associated works, accessories and allied items as specified), price schedulefor related services to be offered from outside and within the purchaser s country, comprehensive annual maintenance contract (camc) of the complete unit (mri 3 tesla) including spares and consumables for 5 years (after initial on-site warranty period), comprehensive annual maintenance contract (camc) of the complete unit (biplane dsa system with large flat panel detector with inbuilt angiography and intervention and stereotactic radiotherapy)including spares and consumables for 5 years (after initial on-site warranty period), comprehensive annual maintenance contract (camc) oft he complete unit (256-slice dual energy spectral high end ct scanner)including spares and consumables for 5 years (after initial on-sitewarranty period), comprehensive annual maintenance contract (camc) of the complete unit (64 slice ct scan machine)including spares and consumables for 5 years (after initial on-site warranty period)
Tender For supply of srphc82278027-crt- p pulse generator for delivery of cardiacresynchronizationtherapy. system should include a current generation crt pulse generator compatible with bipolar steroid-eluting atrial and ventricular leads and a biploar left ventricular lead (coronary sinus ). should provide independently programmable right and left ventricular pulse outputs and interventricular delay ( with the choices of right ventricular alone, leftventricular alone or biventricular pacing as well as the choice of which ventricle is to bepaced first with optimization of delay for pacing of other ventricle ). should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrialtachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch, ventricular rate management etc., pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimal features for introduction, positioning and fixation and documented low displacement rates. safety and efficacy of the system should be well documented. unit: number. ]
Tender For supply of srphc82278027-crt- p pulse generator for delivery of cardiacresynchronizationtherapy. system should include a current generation crt pulse generator compatible with bipolar steroid-eluting atrial and ventricular leads and a biploar left ventricular lead (coronary sinus ). should provide independently programmable right and left ventricular pulse outputs and interventricular delay ( with the choices of right ventricular alone, leftventricular alone or biventricular pacing as well as the choice of which ventricle is to bepaced first with optimization of delay for pacing of other ventricle ). should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrialtachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch, ventricular rate management etc., pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimal features for introduction, positioning and fixation and documented low displacement rates. safety and efficacy of the system should be well documented. unit: number. ]
Tender For cardiac catheterization laboratory - a turnkey project - : "cardiac catheterization laboratory - a turnkey project (floor mounted cardiovascular angiography equipment with digital imaging system for diagnostic and intervention cardiovascular procedures)"