Get complete information related to latest Cathodic Protection Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cathodic Protection Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cathodic Protection Tenders.
Tender For annual rate contract for maintenance of cathodicprotection and associated systems at city gas distribution project at hyderabad vijayawada and kakinada ga for the period of 02 years
Tender For annual rate contract for maintenance, inspection and upkeeping of cross country pipelines, pipeline right of way, sv and rcp stations, cathodicprotection system of iocl between chainage 366.565 km and 1218.73 km of phpl under serpl group 1
Tender For annual rate contract for maintenance, inspection and upkeeping of cross country pipelines, pipeline right of way, sv and rcp stations, cathodicprotection system of iocl between chainage 366.565 km and 1218.73 km of phpl under serpl group 2
Tender For supply of set of items for anti corrosive epoxy paint, colour: basalt grey to ral 7012. (i) pack %u2018a%u2019 and %u2018b%u2019 to be supplied in total 25 litres packing. (ii) colourless low odour mineral spirit to dilute epoxy coating material, qty: 2.5 litres per 25 litres of epoxy paint [i.e. 10 per cent of epoxy paint quantity] to be supplied in suitable packing [20 litres maximum]. matl.& specn : -- rdso specification no. rdso/m&c/pcn/123/2018 with rdso's amendment no. 1b (rev. 2.0) as an additional requirement. [ warranty period: 10 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variationpermitted: max 8 lacs ] ]
Tender For intergard269 (international) -n8010-p063004 , international thinner gta220-n8010-001549 , anti corrosive paint, fresh water tank-n8010-007652 , anti corrosive paint, avgas/avcat-n8010-007653 , h. p. anticorrosive paint for use under non-skid coat- n8010-007694 , h. p. advanced non-skid coating for helo & flight deck-n8010-007693 , inter shield ena 301 alluminium-n8010-p061831 , inter shield ena 300 bronze ani corrosive paint-n8010-p061832 , international thinner gta007-n8010-001174 , tie coat for application of tin free spc a/f paints- n8010-p009601 , brown/light red tin free spc a/f paint for u/w application-n8010-p009602 , red brown/darkred tin free spc a/f paint for u/w application-n8010-p009603 , black colour tin free spc a/f paint for boottop application , interthane 990 white base paint-n8010-p063088 , epoxy based anti corr paint for application in ballast tank- n8010-p009679 , intershiled 300 for weather deck & helo deck-n8010-p064025
Tender For supply of machinery and equipment - uv-vis spectrophotometer spectrophotometer should be of true double beam optics system. sample compartment should have dedicated one reference cell holder and one sample cell holder. system should be czerny-turner monochromator with lo-ray-ligh grade blazed holographic grating or equivalent. system should have a light source of 20-w halogen lamp and deuterium lamp. automatic switch over of light source to be possible and auto position adjustment. system should have a fixed spectral bandwidth of 1nm. system should have facility to use as stand-alone keyboard-display and with pc-controlled software. wavelength range should be from 190 nm to 1100 nm and wavelength accuracy should be 0.1 nm at d2 656.1 nm & 0.3 nm for entire range. stray light: less than 0.02% at 220 nm (nai)less than 0.02% at 340 nm (nano2) less than 0.5% at 198 nm (kcl) photometric range:absorbance: -4 to 4 abs transmittance: 0% to 400% system should have photometric accuracy : 0.002 abs at 0.5 abs 0.004 abs at 1.0 abs 0.006 abs at 2.0 abs(measured using nist930d/nist1930 or equivalent) system should have a baseline flatness: less than 0.0006 abs (1,100 to 190 nm, one hour after light source turned on) system should have a noise level: less than 0.00005 abs (700 nm). detector should be silicon photodiode only. system should have a usb drive port to connect the printers or external drives. system should compulsorily have bio-method mode of measurement for determining dna and protein concentrations. quantitates dna or protein using the absorbance at 260/230nm. system should be capable of identification of organic compounds, chemical reaction tracking and enzyme reaction measurement. pc with relevant hardware including monitor keyboard, mouse., fuming hoods the proposed floor-mounted aerodynamic fume hood (1800 1000 2350 mm) is designed for safe handling of hazardous fumes, ensuring high performance, durability, and compliance with international standards. the system should be a robust, corrosion-resistant, and safety-compliant solution with efficient airflow management, user-friendly maintenance features, and adherence to international laboratory safety standards ideal for advanced research and chemical handling applications.1) design & compliance aerodynamic structure with automatic bypass airflow system. conforms to ashrae 110:2016 / en 14175 standards, including tracer gas containment test. certified ashrae compliance required 2) construction & materials made of powder-coated galvanized iron (gi, 120 gsm, is 277 compliant) sheet thickness: 1 mm (1.2 mm for structural supports) heavy-duty base frame: 60 40 2 mm phenolic resin (6 mm) inner liner: chemical-resistant, smooth, easy to clean ss 304 worktop with 15 mm raised edges for spill containment ss 304 aerodynamic airfoil with anti- corrosive coating 3) dimensions & workspace usable workspace: 1500 mm (w) 850 mm (d) 1180 mm (h) clear viewing height: 1100 mm modular base cabinets with maintenance access 4) coating & finish 8-stage chemical pre-treatment epoxy polyester / polyurethane coating (70 80 microns) corrosion resistance validated by 1000-hour salt spray test 5) functional features vertical sliding toughened glass sash (4 5 mm), counterbalanced openable front top panel for easy maintenance aerodynamic baffle system for efficient fume removal (light to heavy fumes) flow control damper for airflow regulation 6) utilities & safety integrated gas, water, and electrical fittings in corner posts remotely operated, color-coded service valves safety partition between utilities no cable entry below sash (enhanced safety design) electrical fittings: norysis /legrand (230v, 5/16a, 50 hz) 7) accessories pp cup sink with water tap and drainage led lighting with protective enclosure adjustable leveling screws ( 10 mm) storage base cabinets with shelves and self-closing shutters 8) centrifugal blower specifications remote, silent ms + frp blower with chemical-r
Tender For work of coating of condenser tube end plates by brush able ceramic coating and water box by anti-corrosive chemical coating along with supply in unit 1 during coh at khaperkheda tps.