Get complete information related to latest Digital Ultrasound Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Digital Ultrasound Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Digital Ultrasound Tenders.
Tender For corrigendum : rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digitalultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have cont
Tender For corrigendum : supply of disposables - non drugs for the department of anesthesiology - blood set with leuer lock connector, ky jelly, romson -et tubes, microinff et tubes 2.5, microinff et tubes 2.0, meth-hemoglobon assessment for in patients, cavafix 22g- 40cm, cavafix 22g- 30cm, iv cannula 26 g, high flow pediatric heated breathing tube 6 pin for hfnc machine, high flow chamber for hfnc machine, prone ventilation set, icu oral care suction tooth brush -50/pack, non - ionic surfactants, instrument cleanser solution - 1000 ml, yankor suction with on off toggle switch, yankeur suctions tube, wrinch spanner, wall mounted closed suction system 1000 ml for controlling contamination & safe solidification environment, volume based lung exerciser, viaflex fully collapsible bag, ventilator circuit kit - collapsible ventilator tube with c mount & hme bac viral filter, usp class vi cellulose propionate burette set 150 ml with auto shut off valve, tubifix tubular elastic dressing, triggered nebulizer bottle with filter, l-connector, adulyt mask with tubing, trans-oesophageal pacing catheters, t-piece oxygenator circuit, tegaderm / transparent dressings for cvp / art catheter, target control infusion analgesia (tca infusion), syringe pump -mid end, syringe pump -high end, swivel mount with elbow, supraglotic airways (igel type), suction catheter with atrautamic flower tip patented, stimuplex ultra 5cm needles, stimuplex ultra 10cm needles, sterile disposable ventilatory circuit, sterile caps for curoscaps injection port closure, spinal needle- whitaker - 27g, spinal needle- whitaker - 25g, spinal anaesthesia tray, sodalime 5 kg/ carbondioxide abosorbant 5kg / plastic bottle, skin coloured paper tape with wavy gum pattern for high breathability, single lumen catheter cvp 20 g 12 cm/15, single lumen 15 cm catheter cvp 22g 12 cm/15, sharps collectors 5.4 qt, sharps collectors 1.5 qt, self sealing t piece, secure peripheral line dressing, sampling stop cock, safeslide patient shifter, ryles tube with luer connector, quick transfer spike, puncture needle 22 g x 3.8 cm, puncture needle 20 g x 3.8cm, pricking needle with device, pressure monitoring lines polgetyline 1to 2 mm diameter, prefilled saline syring 5ml, precut adhesive soft plaster for iv securement (iv hold) (et hold), (ng hold), powder free sodalime cans, portable safe needle collector, polyurethane ng tubes, polyurethane feeding tube for long term use, polypriopinate oxygen mask with silicon cushion, 1005 odour free, polyklpropinate nebulizer mask with silicon cushion, 100% odour free, ployethelene dehp free connecting line with male & female leur lock, platelet filters, peripheral inserted central venous catheter 2fr 24g 30 cms, peripheral inserted central venous catheter 1fr 28g 20 cms, peg tube, pca (patient controlled analgesia) unit, paediatric epidural set 19-22 g, paed.disposable hme filter, paed.bougie all size, oral care kit for close system- 1 kit., only epidural catheter for 18 canula, only epidural catheter for 16 g canula, oesaphageal stethescope - adults and children, noninvasive cardiac out put picco catheters, non enzymatic detergent wipes, non - ionic surfactants, instrument cleanser solution, nirs probe -adult, nirs probe - pediatric, nerve stimulator with disposable insulated needles & cable, neonatal hme filter, nelson pot (nelson inhaler), nelcath catheter 6-24, needle prick guard cannula without twist or clicks, needle free iv access device with two way reflux valve with triple extension line, needle free iv access device with two way reflux valve with extension line, needle free iv access device with two way reflux valve with dual extension line, needle free iv access device with two way reflux valve, needle free connectors, nasopharyngeal air way size, nasal cap mask, monitoring kit with disposable transducer squeeze flush for pole mounting ( 152cm length), mersilk suture 2.0 with cutting needle, luter access split septum device-stand alone, l