Get complete information related to latest Digital Ultrasound Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Digital Ultrasound Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Digital Ultrasound Tenders.
Tender For corrigendum : tender for the supply, installation and commissioning of fully automated coagulometer on 2 years rate contract as mentioned against item in schedule of requirement.
Tender For corrigendum : rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digitalultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have cont
Tender For corrigendum : supply of methanol ar , thromborel-s compatible to sysmex analyser , siemens calcium chloride coagulation , kit for coagulation la2 kit , kit for coagulation la1 kit , antithrombin iii estimation kit compatible to sysmex analyser , free protein s estimation kit compatible to sysmex analyserkit of 120 test , protein c estimation kit compatible to sysmex analyser , siemens factor ix kit for sysmex coagulation analyzer , siemens factor viii kit for sysmex coagulation analyzer , factor v deficient plasma , kit for plasmodium vivax and falciparum immunochromatographic technique aldolase and hrp2 estimation , micro tips 5-200 ul , ready made giemsa stain , ca clean i for fully automated coagulometer compatible to sysmex analyser , fdp determination kit , g-6 pd kit of 12 testvisual method , leishman stain readymade with dilution buffer 6 point8 ph , fibrinogen del kit , siemens actin fs kit for sysmex coagulation analyser , western green disposable tube for esr test , hp laser cartridge no cc88a 88a for five parts haematology counter , control plasma normal compatible to sysmex analyser , control plasma p compatible to sysmex analyser , blood capillary-fix pr tubing kit , blood capillary- fix pr deuterium lamp , blood capillary-fix pr capillary catridge ) /bid number : gem/2026/b/7427258 * /dated: 16-05-2026 & & / bid document 1 / 27
Tender For corrigendum : supply of gmc jagdalpur equipments c c - five part fully automated cell counter , fully automated coagulometer , fully automated rotary microtome , fully auto analyzer , automated electrophoreses
Tender For corrigendum : supply and installation of medical laboratory equipments on cost per test (cpt) basis to biochemistry, pathology andmicrobiology at central laboratory - third party controls for integrated bio chemistry and immunoassay machine kmio kmio, controls for cbc kmio, third party controls for cbc kmio, calibrator of integrated bio chemistry and immunoassay machine, controls for integrated bio chemistry and immunoassay machine kmio, third party controls for integrated bio chemistry and immunoassay machine kmio, calibrator for coagulation analyzer kmio, controls for coagulation analyzer kmio, automated slide with smear, any new tests should be added(in action column), complete urine analysis kmio, drug sensitivity test for cerebrospinal fluid (csf) / all body fluids (blood/urine/ascites/pleural fluids/pus /sputum, etc) kmio, automated blood culture and sensitivity kmio, urine routine- ph, specific gravity, sugar, protein and microscopy kmio, ckmb kmio, troponin i kmio, vitamin b12 kmio, pro bnp kmio, s protein electrophoresis (spep) kmio, urine immunofixation kmio, urinary protein electrophoresis (upep) kmio, igm kmio, igg kmio, iga kmio, s immunoglobulins kmio, he4 kmio, ferritin kmio, nse kmio, ca 15.3 kmio, ca 19.9 kmio, free t4 kmio, free t3 kmio, anti tpo kmio, ant-thyroglobulin (anti tg) kmio, thyroglobulin (tg) kmio, t3/t4/tsh kmio, tsh kmio, t4 kmio, t3 kmio, beta hcg kmio, psa kmio, ca 125 kmio, afp kmio, cea kmio, folic acid kmio, vitamin-d kmio, s galactomannan kmio, s methothrexate kmio, b-2 microglobulin kmio, s free light chains kmio, urinary vma kmio, s lipase kmio, a amylase kmio, s magnesium kmio, serum phosphorus kmio, fluid analysis (sugar protein) kmio, creatinine clearance (2 hrs) kmio, rft (urea creatinine) kmio, glucose tolerance test (gtt) kmio, lipid profile. (total cholesterol, ldl, hdl, triglycerides) kmio, calcium kmio, c reactive protein (crp) quantitative kmio, electrolytes (na/k/cl) kmio, lactate dehydrogenase (ldh) kmio, liver function test (lft) (sgot,sgpt,alp, total protein, albumin, globulin, ag ratio, direct,indirect & total bilirubin) kmio, uric acid kmio, creatinine kmio, urea nitrogen (bun) kmio, glucose random kmio, glucose pp kmio, glucose fasting kmio, serology (by chemiluminescence method)hcv antibodies, serology (by chemiluminescence method)hbsag, serology (by chemiluminescence method)hiv antibodies, mycobacteria (afb) smear/culture examination fluids kmio, mycobacteria (afb) smear/culture examination urine kmio, mycobacteria (afb) smear/culture examination pus kmio, mycobacteria (afb) smear/culture examination sputum kmio, fungal culture fluids kmio, fungal culture pus kmio, fungal culture stool kmio, fungal culture urine kmio, fungal culture ent (ear/nose/throat) kmio, fungal culture sputum kmio, bacterial culture & sensitivity fluids kmio, bacterial culture & sensitivity pus kmio, bacterial culture & sensitivity stool kmio, bacterial culture & sensitivity urine kmio, any other, bacterial culture & sensitivity ent (ear/nose/throat) kmio, consumables for fully automated coagulometer, consumables for fully automated identification and sensitivity system with mic values with amr surveillance assistance software, consumables for fully automated blood culture system, consumables for fully automated 5 part cell counter with retic and slide processor, consumables for fully automated integrated chemistry and immunoassay analyzer, third party controls for coagulation analyzer kmio, controls for microbiology machines kmio, controls for maicrobiology machines kmio, third party controls for microbiology machines kmio, controls for integrated bio chemistry and immunoassay machine kmio kmio, bacterial culture & sensitivity sputum kmio, d-dimer kmio, fibrinogen. kmio, thrombin time (tt) kmio, activated partial thromboplastin time (aptt), prothrombin time (pt)/ international normalized ratio (inr) kmio, erythrocyte sedimentation rate (esr) kmio, peripheral smear kmi