Get complete information related to latest Digital Ultrasound Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Digital Ultrasound Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Digital Ultrasound Tenders.
Tender For corrigendum : rate contract for medicine - stainless steel abdominal hysterectomy set, n.s.v set (s.s), g.v set, self abdominal detractor, m.t.p set., vaccine carrier (small size), x-ray digitalisation with high-end cr system (with installation & 1 yers. warrenty) console software with mulitmodality work station the cr system should have advances workstation provided with 17" high resolution monitor, keyboard & ouse, with the fol., digitalultrasound machine colour dopler (high resolution ) with 4 probe, semi auto analyzer, fully automated bio-chemistry analyzertechnical specificationsthroughput-150t/hr (constant with both mono and double reagent)system function-random access/stat/batchtest method-end point, fix time, kinetic, (single/double reagents chemistry, mono/ bio-chromatic measurements)calculation methods-1 point linear, 2 point linear, exponential, logit log3p, logit log 4 p, logit log 5p, spline, line graph, k factorblank-reagent blank, sample blank, pre sample blank, pre reagent blanksample tray-40 position, sample volume :2-30 ui, 0.1 ul increment, micro cup, & test tube can be used for samplereagent tray-80 position, reagent volume: 20-300 ul, 1 ul incrementmixing system-teflon coated mixersample probe-1 needle with liquid detector, shock sensoroptics-halogen-tungsten lamp, absorbance range: 0-4.0 abs resolution: 0.0001 abs.diffraction photometry with wave length: 340, 405, 450, 505, 546, 578, 630, 700nm & 4 more optionswash station-12 step washing, 4 needle wash station, 1 dry pad, external needle cleaningcalibration-linear and non-linearqc-multi-level qc setup with levy-jennings graph and westgrads multi rules with mean sd, and cvwater consumption-not more than 6l/hrtemperature-reagent: 2-14 c (24 hr refrigeration), reaction cuvette: 37c 0.1 humidity- 80%system interface-usbpower requirement-ac 220v 10%, 50/60 hzdimensions-750 mm*560mm*530mm, hotair oven, binocular microscope (olampus), centri fuge machin (good quality), micropipette (0-50 microliter), micropipette (0-500 microliter), micropipette (0-1000 microliter), microtips (0-50 microliter), microtips (0-1000 microliter), bed side screen with cloth 1"round pipe with wheel, sponge holding (all size), artery forceps 6" curved, artery forceps 6" straight., artery forceps 8" curved, artery forceps 8" straight., artery forceps 4" straight., alliys tissue forcep (all size curved straight), mosquito forcep (all size curved straight), scissor 6 " curved (all size), scissor 6 " straight (all size), scissor mosquito straight. (all size curved, straight), diatheromy (machine), laparoscopic instrument full set (best quality), needle holder 8 "curved, needle holder 8 " straight, needle holder 6 "curved, needle holder 6 " straight, needle holder 4 "curved, needle holder 4 " straight, doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside, elisa reader with washer mechine with printer & ups., doner couch (3 motor), blood weighting mechine, blood band refrigerator (300 bag) temp.display outside ( best quality), fully automated chemiluminescence analyzer(clia) 1. system should be fully automated walk -away with continuous loading facility.2. analyzer should have able to perform thyroid, bone, cardiac, fertility, diabetes and anemia profile test.3. working principle of system should be micron super paramagnetic particles platform with alp labeled reagents and amppd substrate.4. must have 3 phase magnetic separation with precisely controlled temperature.5. analyzer should have photon counting detection mode with photomultiplier photo counter with led reference module.6. the analyzer must have vortex non-touch mixing which can reduce carryover., 7. throughput of the system should be more than 180 tests in a hour.8. system should have 15 reagents onboard with onboard 2 -8 nonstop refrigeration facility 9. system should have at least 50 sample positions and continuous loading facility.10. system should have cont
Tender For supply of spare parts and health store materials and equipment for repair work group a item. - indigenous iron axe (with wooden handle), iron pickaxe (with wooden handle), iron hoe (with wooden handle), iron sheet (16 gauge), iron sheet (18 gauge), plastic bins, iron crowbar, iron flat bar, iron angle bar, iron pan (tasla), shovel, rickshaw trolley rear rim (large, with spokes), rickshaw trolley nylon tire, molded inner tube, rickshaw trolley front rim assembly (complete: jumbo axle, hub, and spokes), rickshaw trolley small rim (with spokes), rickshaw trolley nylon tire, rickshaw trolley inner tube, rickshaw trolley fork, rickshaw trolley axle, handcart axle, rock salt, polysheet, biodegradable polybags, jute hessian cloth, new iron wheel (for handcarts), iron bucket, small hand hoe (faruhi), rickshaw trolley bins (for door-to-door waste collection)
Tender For supply of spare parts and health store materials and equipment for repair work group b item. - list of equipments group b, , , , ball head racers, , , , , , , , , free wheel, , , high carbon stell balls, high corbon stell balls, , , rikshatrolly free bush with bolt, , , , , , , , ( ), ,
Tender For auction sale of depot miscellaneous scrap - 126002tfb26b, 98414513, quantity: 10520 kgs. scrap condemned unserviceable electrical items consists of track feed battery chargers, volume controls, conversion units, spite fire telecom unit, amplifiers of sorts/sizes, vhf adopters, qd relays, transmission kits, cross talk meters, ups, current regulator, stabilizer, telecom interlink, column speakers, firewall routers, microphone, circuit controller, solar charge controllers ,power supply units, adopters, route locators, pa mixers, muxs, torch lights, mega phones, video encoders,2 wire way station equipments, ballasts, magnetic amplifier, current transformer, magnetic coils, harmonic filters, rotary switches, ej box, hmu, universal voltage controller, et, ovp relay of rru/erru, vhf sets, ethernets, psus, chargers, signalling gears, hot plate, dc converters, hand held search light, vf transformers, gto, diode, 6way terminal, terminal board, rotary switch, chokes, wire block bell equipment, block filter unit, mcbs, ekt, hpsv/mh chokes , fuse monitoring unit, health monitoring unit, earth leakage drivers, trans rectifiers, led street light fittings, defective ct coils, axle tx/rx coil, gto valve set, wre modules, gg modules, chba modules, smr modules, special repair contractor, annual rate contract chute, eld, hassdac, mcb, pcb, meters, transformers of power supply units, inverters, regulators, isolation transformers, b-type chokes, auto by pass units, sge block instruments, solar charger controller and other battery charging and signalling equipment of various makes, types, capacities of sorts and sizes, full or broken, with or without windings, ms- plastic- rubber attachments. total gross weight: 10520 kgs. approx copper weight: 2054.205 kgs. approx aluminium weight: 2609.96 kgs. approx brass weight: 2.88 kgs approx hazard waste weight: 558.7 kgs approx plastic weight: 124.8235 kgs approx ferrous and others weight: 5105.1915 kgs. special note: purchasers of electrical and electronic equipment covered under e-waste rule 2016 in its schedule i should have registration from central pollution control board new delhi. the notification may be downloaded from the website of ministry of environment and forest notification g.s.r 472 [e] dated 10.06.2015 published in the gazette of india. note: delivery by weighment basis only. location: bin.no.6002- godown no- 6. hsn code: 85041090. gst: 18 percent. special note: overload of the carrying capacity of the vehicle will not be permitted at the time of taking delivery as per mv act 1988