Get complete information related to latest Earth Terminal Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Earth Terminal Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Earth Terminal Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :45736160 Due date: 09 Jul, 202609 Jul, 2026 NA
Tender For supply of motor protection circuit breaker (mpcb) for water pump with auxiliary contact (1 no + 1nc)and terminal block db, current rating: 1-1.6 amp,thermal release range :1.0 to 1.6 a, voltage rating 690 v, class 10, breaking capacity: 50 ka, 3 pole as per rdso spec no: rdso/pe/spec/0192-2018 (rev.1) or latest. suitable for use in switch board cabinet of lhb type ac coaches. make: abb/schneider/siemens/l&t. [ warranty period: 30 months after the date of delivery ] ]

CTN :45738480 Due date: 21 Jul, 202621 Jul, 2026 23.32 Lacs
Tender For supply of 9u rack , 2kva ups with rack and 06 nos 18 ah battery with each set 30 min backup , 2 port io box , earthing terminal box with accessories , chemical type earthing rod with accessories , earthing pit installation job , 12 core ofc cable , lying fibre cable , 25 mm pvc casing caping , 50 mm casing caping , earthing cable 1c 4sqmm , joint closure , fibre splicing per fibre , 3 or 4 pvc pipe , flexible conduit , gi pipe 50mm , duct 40mm , danger tape , route marker , cat 6 cable , jack panel 24 port , switch socket power supply board , power cable 3 core 2.5 sqmm , power cable 3 core 4 sqmm , cat 6 cable 1 mtr , lc e2k ofc patch cable 5 mtr , lc e2k ofc patch cable 10 mtr , otb box with e2k 12 port connector , lugs ring type , 40 mm coupler , charges of i c of supplied equipment , material transportation

Central Government/Public Sector

CTN :45715059 Due date: 29 Jul, 202629 Jul, 2026 NA
Tender For supply of mpcb (motor protection circuit breaker) suitable for ventilation fan units 1 & 2, thermal release range (rated current 2.5-4a), class: 10, breaking capacity: 50ka, pole: 3p, rated voltage: 415vac, 1no + 1nc auxiliary contact block, and conforming to rdso letter no. el/7.1.108/mssbc dated 17.09.21- make ? legrand / siemens / schneider / l&t / eaton / abb only.[ warranty period: 30 months after the date of delivery ] ]

CTN :45689738 Due date: 06 Jul, 202606 Jul, 2026 40.0 Thousand
Tender For supply of relay swtch , main relay , earth terminal , system protection valve , bearing needle , oil seal , copper washer 18 dia , copper washer , washer , assy clutch disc pressure plate

CTN :45689515 Due date: 16 Jul, 202616 Jul, 2026 NA
Tender For supply of auxiliary contacts for mpcb , series -3rv19 , aux contacts - 1no and 1nc each for trip & s or ct trip , siemens make , front auxiliary contacts for mpcb , series-3rv19 , aux contacts-1no 1nc , siemens make , mpcb , series-3rv11 , relay function , size-s0 , rating-2.5a , ol range-2.2 to 3.2a , siemens make , mpcb , series-3rv11 , relay function , size-s0 , rating-3.2a , ol range-9 to 12.5a , siemens make , mpcb , series-3rv11 , relay function , size-s0 , rating-20a , ol range-14 to 20a , siemens make , mounting for mpcb with door coupling rotary mechanism , series-3rv19 , size-s0 , with door interlock , padlocking facility , extension shaft 300mm , siemens make , power contactor , series-3tf , duty-ac-3 , rating-16a , aux contacts , size-s1 , coil voltage-ac 110v , siemens make , power contactor , series-3tf , duty-ac-3 , rating-32a , aux contacts , size-s2 , coil voltage-ac 110v , siemens make , power contactor , series-3tf , duty-ac-3 , rating-22a , aux contacts , sizes1 , coil voltage-ac 110v , siemens make , push buttons , mushroom actuators for emergency stop , series-3sb5 , red , mushroom actuator 40mm push to trip , turn to release with 1nc , siemens make , push buttons , modular push button actuators , series-3sb5 , aux contacts-normal , black , opaque actuator , siemens make , auxiliary contacts for pb , contact blocks for pb , selector , key actuators , series-3sb5 , aux contacts-1no , for rear mounting , siemens make , contactor relays , series-3th3 , duty-ac-15 , rating-10a , aux contacts-2no 2nc , size-s0 , coil voltage-ac 110v , siemens make , aux contact block , series-3tx4 , aux contacts-1no , for 3tf30 to 35 , 3th30 , siemens make , aux contact block , series-3tx34 , aux contacts- 1nc , for 3tf30 to 35 , 3th30 , siemens make , trolley limit switch , normal arrangement , 2no 1nc contacts , siemens make , super switch- d or o , nd type , rating-20a , 3km47301ya00 , frame size-size 1 , suitable for-din type fuse link of size 00 or 000 , siemens make , selector switch , series-3st , rating-6a , black knob , ammeter selector , siemens make , add on block 1no 1 nc , 230v dc , 6a , siemens make , spring charge motor -220-250vdc new ic , siemens make , spring charge motor -220-250vdc old ic , siemens make , spring charge motor -220-250vdc , 4100rpm , hdz-202.06 , 90310059k , siemens make , tripping , closing coil voltage -220-250vdc vp , siemens make , tripping , closing coil voltage-220-250vdc ic , siemens make , control contactor 2no 2nc , coil volatge -220 v dc , siemens make , control contactor 2no 2nc , coil voltage- 220v dc , siemens make , control contactor 4no , coil voltage-220 v dc , siemens make , 12a power contactor with 1nc aux. contact , coil voltage-240v ac , siemens make , 16a power contactor , coil voltage- 220v dc , siemens make , 32a power contactor , coil voltage- 110v ac , siemens make , 63a power contactor with 2no 2nc aux contact , coil voltage-110v ac , siemens make , 110a power contactor with 2no 2nc aux. contact , coil voltage-110v ac , siemens make , 10a , ac 15 aux. contactor with 2no 2nc aux . contact , coil voltage-110v ac , 10a , ac 15 aux. contactor with 2no 2nc aux . contact , coil voltage-220v dc , siemens make , 10a , ac 15 aux. contactor with 4no aux . contact , coil voltage-220v dc , siemens make , 1 nc aux. contact block , siemens make , 1 no aux. contact block , siemens make , 1no 1nc left aux. contact block , siemens make , simocode pro-v motor protection , control device with aux. supply 110-240v ac or dc , with 4i or 3o freely assignable , communication via profibus-k91b , current measuring device for motor protection , control device having setting range - 0.3-3a with straight- thorough transformers- k91m , current measuring device for motor protection , control device having setting range - 2.4-25a with straight- thorough transformers- k91m , current measuring device for motor protection , control device having setting range - 10-100a with straight- thorough tra

CTN :45048307 Due date: 31 Jul, 202631 Jul, 2026 NA
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp

corporations/Associations/Others

CTN :45667085 Due date: 29 Jun, 202629 Jun, 2026 NA
Tender For fire work at esic haryana. - (a) supplying, installation, testing and commissioning of electric driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required :(b) horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp squirrel cage induction motor, tefc, synchronous speed 1500 rpm, suitable for operation on 415 volts, 3 phase 50 hz, ac supply with ip 55 protection for enclosure, horizontal foot mounted typewith class-f insulation, conforming to is-325.(d) m.s. fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plasteredwith anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required:(diesel driven pump)(b) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520.(c) suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulatedwith 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event offault with audio indications, painted with post office red colour etc. as required.(d) m.s fabricated, common base plate, coupling, couplingguard, foundation bolts etc. as required.(e)suitable cement concrete foundation duly plasteredand with anti vibration pads., 2280 lpm at 70 m head, (a) supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (jockey pump)(b)horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is : 1520.(c) suitable hp squirell cage induction motor tefc type suitable for operation on 415 volts, 3 phase 50 hz ac supply with ip 55 class of protection for enclosure, horizontal foot mounted type with class-f insulation, conforming to is : 325.(d) m.s.fabricated common base plate, coupling, coupling guard, foundation bolts etc. as required.(e) suitable cement concrete foundation duly plastered and with anti vibration pads., 180 lpm @70m head, fabrication, supply, insallation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :, incomings630a, 50ka 4 pole mccb, ics=100% icu rating digital voltmeter 0-500v with selector switch ammeter (0-630 a) with selector swtich & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps set of copper bus bar 800amps outgoings (note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump200 amp, 50ka tpn mccb, ics=100% icu, with f

CTN :45649771 Due date: 04 Jul, 202604 Jul, 2026 NA
Tender For supply of m l for point wiring with pvc insulated unsheathed single core multi stranded copper conductor 1 5 sqmm 1100 volts grade cable frls passing through pvc casing caping including accessories , one 3 pin switch socket combination 5 amps on the same board with other switches 28 points , one 3 pin switch socket combination 5 amps independent 30 points , one bell point controlled by one push button 4 points , all as per item no 1 above but with 2 5 sqmm cable for one three pin 15 amps socket out let controlled by one switch 18 points , s f modular switch 1 module single pole one way 6 amp conforming to is 3854 and isi marked complete all as direcred 84 nos , s f modular switch 1 module single pole one way 16 amp conforming to is3854 and isi marked complete all as direcred 18 nos , s f ceiling rose with earth terminal connection 3 terminal pvc polycarbonate isolated body of size 60x50mm 26 nos , s f modular socket 6a 3 pin 2 module conforming to is 1293 2019 and isi marked complete all as direcred 58 nos , s f modular socket 6 16a 3 pin 2 module conforming to is 1293 2019 and isi marked complete all as direcred 18 nos , s f modular pvc gang box screwless of 6 module for mounting of modular switches and sockets including blank plate for blank module 8 nos , all as per item no- 8.00 above but of modular pvc gang box 4 module 22 nos , all as per item no- 8.00 above but of modular pvc gang box 3 module 38 nos , all as per item no- 37.00 above but of modular pvc gang box 2 module 5 nos , sf modular white cover plate with frame 6 module 8 nos , sf modular white cover plate with frame 4 module 22 nos , sf modular white cover plate with frame 3 module 38 nos , sf modular white cover plate with frame 2 module 5 nos , supply and fix led aluminium housing of batten fitting 20 watt 240v 4ft cdlnw comprises of aluminium extruded channel in thermally conductive material with decorative end cap , s f mcb db spn conforming to ip 43 ik 09 with acrylic double door 12 way complete with din rail neutral and earthing bar 11 nos , s f mcb spn 63 amp 10 ka 230 volt c curve type 11 nos , s f mcb single pole 20 amp 10 ka 230 volt c curve type 81 nos , s f cable pvc insulated pvc sheathed armoured frls 1100v grade 2 core 6 sqmm stranded copper conductor electric cable laid on wall roof duct complete with proper saddling , supply and fix single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole mcb of capacity 20 amp, 240 volts complete all as specified and directed 26 nos , m l for pvc insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross-sectional area 50 sq mm 3.5 core 140 rm , s f vtpn db 8 way suitable for flush mounting and surface mounting with 250 a copper busbar for each phase with 2 neutral bar 2 earthbar and cable ties , s f mccb tpn 100 amp icu 16 ka 415v with magnetic release complete all as specified and directed 8 nos , s f mccb 4 pole 160 amp icu 36 ka 415v with magnetic release complete all as specified and directed 2 nos , m l for snap- on trunking system with cover angles bends and all accessories and fitting of size 50x130 mm with 2- compartment fixing on wall complete all specified and directed 90 rm , s f modular bell push switch 1 module single pole one way 6amp isi marked 4 nos , s f in replacement with modular electric bell ding dong ac 230v single pole 4 nos //bid details 2 / 28

CTN :45647762 Due date: 02 Jul, 202602 Jul, 2026 NA
Tender For supply of spare for generator transformer & cooling water system - winding temeperature transmitter, dual output: 4-20ma, 90-260v ac/dc, precimeasure , current converter unit ccu18, input-pt100 rtd, output: 4-20ma dc,90-260v ac/dc , digital winding temp. remote indicator, range-0-150°c, model no. 2245.t2, precimeasure , digital oil temp. indicator remote, range-o-150°c, model no. 2245.t2, precimeasure , mcb breaker 4 poles, 10a, 10ka, c-curve, 415v ac, siemens , mcb, 6a, 2 pole, 10ka, c-curve, 240vac, siemens , mcb, 16a, 2 pole, 10ka, c-curve, 2 40vac, siemens , mcb, 2a, 1p, 10ka, c-curve, 240v ac, siemens , mcb 10a, 1p, 10ka, c-curve, 240v ac, siemens , mcb, 6a, 2pole, 10ka, c-curve, 110v, ac, siemens , moulded case ckt breaker (mccb) 32a, 55ka, 4pole, 415v ac, siemens , power contactor, 4 poles, 415vac, 12a, 415v with add on 2no+2nc (aux. supply 110v ac)3tf31-10-0a , aux. contactor (ac supervision), 110v ac, 2no +2nc,3th30-22-0a , aux. contactor, 110v ac, 3no+1nc with add-on aux. contact block 2no+1nc,3th30-31-0a , motor thermal overload relay (4-6.3a),3ua50 001g , relay used in the cooler control circuit (minilec) minilec d1hls1 , time delay relay, 110v, 0.1-10h with 2 c/o contact, micon 2a5dt5 , selector switch 2 way with off, 6a, 240v 2 pole, type: s10-61025-bb, make: l&t/kaycee , selector switch, 10a, 440v, 2 ways with off 4 pole, make: l&t/kaycee , selector switch, 2way on off,10a, 440v, 10 pole , auxiliary transformer, 415v/55-0-55 (110v), 500va, make: l&t/kaycee , led (red, green) for pump on indicator suitable, 110v ac , differential pressure gauge (fiebig) 0-1.5 kg/cm 2 above to 380v 30w 50va , water leakage detector sapcon probe length 68mm , resistance temp. detector (rtd) for (wti and oti), pt 100, precimenasure , pump main & stan - by selector switch, , nylonwasher size 2.5tkx4 id x8 od , generator , carbon brush (50.8x38.1x25.4) mm, hm6 grd , brush holder , slip ring assembly (refer annexure-10) , insulation stud with epoxy with fire , retardant, shaft l= 315 from flange face, ø55, flange l 150, width 90, flange thickness 20, hole ø18, hole spacing(l) 108, hole spacing (w) 46 measurements in mm , duplex rtd pt/100 l-930, b-630, h 370 (mm) , dail type thermometer (dtt)l=35 m,.length of bulb--100mm, bulb coneection-standard p.f. 3/4 double union. 5 kg/cm2, type-gas filled, dial siz- 150 mm or 160 mm. accuracy+-2-degree celcus. (refer annexure-1) , thermostat for (guide bearing) , max operating voltage: 220v dc (±10%) , temperature range: 20°c to 100°c , max working temperature: 110°c , capillary tube length: 6 meters , switch action: 1 spdt for alarm and 1 for trip , (at two different temperatures) , differential temperature: 2°c to 5°c , accuracy: ±3°c of set point , repeatability: ±3°c , working temperature: 110°c ((refer annexure-2) , thermostat for lower guide bearing, (spec same as sl, 35) , thermostat for space heater (maximum current capacity: 1 amaximum operating , voltage: 250 vdc ±10%temperature range: 25°c to 90°ccapillary tube length (l): 5 meters switch action: spdtdifferential temperature: 3°c to 5°caccuracy: ±3°c of set pointsetting temperature:75°c for bearing & hot air40°c for heater controlrepeatability: ±3°c (refer annexure-3) , motorised valve, actuator type- k300 g1/g2a, enclosure -wt to ip 68, output speed-36 rpm, max tourque-305nm, motor 1.2 kw, 415v, average load-3.10a and locked rotor, 25a (roterz brand) , gate valve (1/2") brass , hex bolt m12*30 , hex bolt m12*50 , hex bolt m6*20 , hex bolt m16* 68 , stud m12*100 , cooling water system , moulded case circuit breaker (mccb), 500a 3p 50ka 415vac, mccb, with magnetic releases, dsine dn3-630m,500a, make-l&t , copper 220v mnx 550/650 spare coil cat no:cs94193(10 each) co , power contactor, 250a, 3p, power contactor with 240v ac coil, aux 2no+2nc contacts, mnx250, make-l&t latch relay, latch relay with 3no+1nc, 240vac coil aux supply with mechnical interlock electrical reset , aux contactor, auxilary contactor

CTN :45614743 Due date: 06 Jul, 202606 Jul, 2026 51.88 Lacs
Tender For requirement of abb make spares of chp and main plant electrical for unit i to iv of phase i and ii of ctpp, chhabra- single pole assembly, 1sda045691r1 , single arc chamber, 1sda045697r1, operating mechanism, 1sda053988r1, closing spring, 1sda053990r1, main shield and lateral covers, 1sda047828r1, shutters for fixed portion, 1sda038261r1, closed door withdrawing mechanism, 1syn851001r00, coils support, 1sda038339r1, i1/i4 mechanical flag and opening solenoid set, 1sda063404r1, lifting plates set, 1sda038093r1, maintenance kit, 1sda070245r1 , earth sliding contact, 1sda045722r1, spring charged flag set, 1sda065703r1, gasket for panel's door, 1sda038096r1, spring charging motor, supply voltage 220 vdc, 1sda038310rl, sliding contacts board for fixed portion, 1sda063402r1, sliding contacts board for moving portion, 1sda063403r 1, main shield for ronis key lock, 1sda063405r1, pr120/v cables, 1sda063497r1, lateral guides for fixed part, 1sda076320r1, service screw kit, 1syn953013p3001, protection release type: pr121/p-lsig, 3p, 1sda058195r1, protection chain - pr121/p - lsig, e1, in = 800 a, 3p, 1syn965872r8222, protection chain - pr121/p - lsig, e1, in = 1250 a, 3p, 1syn965872r8225, 3 pole power contactors (coil voltage 110 vac), 9 amp, ac3, 50/60 hz, 1sbl137001r1310, 12 amp, ac3, 50/60 hz, 1sbl911074r8410, 17 amp. a16-30-10, ac3, 50/60 hz, 1sbl181001r8410, 32 amp. a30-30-10, 1sbl281001r8410, 80amp, ax80-30-11, ac3, ax80-30-11, 185amp, af185-30-11, ac3, af185-30-11, 205 amp. af205-30-11, 1sfl527002r8411, 265amp, af265-30-11, ac3, af265-30-11 , 3 pole power contactors (coil voltage 230 vac), 9 amp,a09-30-10-80, ac3, 50/60 hz, 1sbl141001r8010, 9 amp,a09-30-01-80, ac3, 50/60 hz, 17amp, a16-30-10, ac3, 1sbl181001r8010, 32amp, a30-30-10, ac3, 1sbl281001r8010 , 32 amp, ax32-30-10,ac3, 50/60 hz, 1sbl281074r8010, 37 amp, a40-30-10, ac3, 1sbl321001r8010 , 75 amp, a75-30-00-80, ac3, 50/60 hz, 1sbl411001r8000, 3 pole power contactors (coil voltage 415 vac), 18 amp, ax18-30-10 ac3, 50/60 hz, 1sbl921074r8610, 32 amp, ax32-30-10, ac3, 50/60 hz, 1sbl281074r8610, 40 amp, ax40-30-10, ac3, 50/60 hz, 1sbl321074r8610, 50amp, ax50-30-11, ac3, 1sbl351074r8611, 75 amp,a75-30-00-80, ac3, 50/60 hz, 1sbl411001r8600, power contactors (coil voltage 220vdc), 9amp, af09-30-10-13, af09-30-10-13, 50 amp, af50-30-11, af50-30-11, 65 amp, af63-30-00, af63-30-00, power contactors (coil voltage 24vdc), 9amp, al9-30-10, 1sbl143001r8110, auxiliary contactors, no. of contacts 4, 2no+2nc, n22e coil voltage 110 vac, 1sbh141001r8422, no. of contacts 4, 3no +1nc, n 31 e 84, coil voltage -110vac, 1sbh141001r8431, no. of contacts 4, 4no, n 40 e 84, coil voltage 110vac, 1sbh141001r8440, no. of contacts 4, 4no, n 40 e 80, coil voltage 240vac, 1sbh141001r8040, no. of contacts 4, 2no +2nc, n 22 e 80, coil voltage 240vac, 1sbh141001r8022, no. of contacts 4, 3no +1nc, n 31 e 80, coil voltage 240vac, 1sbh141001r8031, no. of contacts 4, 2no+2nc, n22e coil voltage 440 vac, 1sbh141001r8622, "no. of contacts 4, 4no, nl 40 e 88, coil voltage 220 vdc, 1sbh143001r8840", no. of contacts 4, 2no+2nc, nl22e coil voltage 220 vdc, 1sbh141001r8822, no. of contacts 4, 3no +1nc, nl 31 e 88, coil voltage 220 vdc, 1sbh143001r8831, no. of contacts 4, 2no+2nc, nl22e coil voltage 24 vdc, 1sbh143001r8122, add on block., 2no+2nc, ca5-22 e (front mounted ), 1sbn010040r1022, 1no+1nc, cal5-11 (front mounted), 1sbn010020r1011, 1no, ca5-10 (front mounted), 1sbn010010r1010 , 1nc, ca5-01 (front mounted), 1sbn010010r1001 , 1no+1nc, cal18-11b (side mounted), 1sfn010720r3311, 1no, ca5x-10 (front mounted), 1sbn019010r1010 , 1nc, ca5x-01 (front mounted), 1sbn019010r1001 , 2no+2nc, ca5x-22e (front mounted ), 1sbn019040r1022, 4no, ca5x-40e (front mounted), 1sbn019040r1040, auxiliary contact, hkf1-11, 1sam201901r1001, 1no+1nc (side mounted), cal19-11b, thermal overload relays, range 1.0-1.6 amps., ms325-1.6, range 1.0-1.4 amps., ta25du 1.4m, 1saz211201r2023, range 1.3-1.8 amps, ta25du 1.8m, 1saz211201r2025, range 1.7-2.4