Get complete information related to latest Electrometer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Electrometer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Electrometer Tenders.
Tender For digital voltmeter with led display, range 0-1000 v ac, class-1, true 4 digit, 3 line, 7 segment led display. size-96 sq.mm,input volage 800 v ac l-l parameter displayed, ac line to neutral voltage (ry, yb, br, rn, yn, bn), with aux supply 24/110v dc 4va class: 1.0 suitable for lhb power car and lslrd.conforming to rdso specifcation rdso/pe/spec/ tl/0195 2019 (rev.0) of make:-ae/ socomec/ rishabh/ siemens/ yokins only [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of voltmeter moving coil type range 0-200v dc, size 96 x 96mm with rubber gasket, accuracy class1, as per is : 1248-1984 or latest. make as per sr.no.9 of bill of material (bom) of rcf specn.no.edts-041 rev-b, annexure-a. [ warranty period: 30 months after the date of delivery ] ]
Tender For digital voltmeter size 96 sq mm, 4 digit led display range 0-150 v dc, cl 1, aux supply 110 v dc as per rdso specifcation no. rdso/pe/spec/tl/0195 2019(rev.0) and rcf spec no. edts-333 rec-00 suitable for sbc of lslrd coaches make: ae/ muler+zeigler/ rishabh, yokins only or any other make approved by rdso/rcf/icf/mcf (submission of approval at the time of tender). warranty as per irs conditions and supplier shall submit oem test certifcate, calibration certifcate along with meter. [ warranty period: 30 months after the date of delivery ] ]
Tender For tender for supply of supply and commissioning of multimedia projector with 1920 x 1200 (wuxga resolution. as per attached specification., supply, installation, testing and commissioning of 86 inches uhd (4k) ir-type touch interactive digital board as per the specification attached, panel ammeter (analog) withour shunt, range-0-1000a dc cab size - 145 x 145 mm, make: meco/shanti/agronic or similer, digital ammeter with led display, size 96 mm x 96 mm, multiline for measuring current r,y & b, 0-600 amps ac, ctr, 1a/5 a programmable, with aux. supply 110 v dc, 4 va, class 1.0 confirming to rdso/pe/spec/ac/0200-2020 (rev. 0) suitable for switch board cabinet of lhb eog economy coaches. make acceptable: as per bom annexure d, sr no. 9, ae, socomec, rishabh, siemens, schneider, yokins, l& t only. firm shall submit oem/authorized dealer certificate., digital voltmeter with led display, size 96 mm x 96 mm, multiline for electrical panel of lhb economy ac coaches conforming to rdso spec. no. rdso/pe/spec/ac/0200-2020 (rev. 0) for measuring ry, yb & br. voltage 800 v l-l, with aux supply 24/110 v dc, 4 va. class: 1.0. make acceptable: as per bom annexure d, sr no. 14, ae, socomec, rishabh, siemens, yokins, l& t only. firm shall submit oem/authorized dealer certificate.
Tender For corrigendum : supply of repair and preventive maintenance of dg set ranchi oa - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva //bid details 2 / 35
Tender For corrigendum : providing of repair maintenance of dg set hazaribag - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : providing of repair and maintenance of dg set under daltonganj - breakdown call, inspection, fault finding dg set site distance up to 50 km , breakdown call, inspection, fault finding dg set above 50 up to 100 km , breakdown call, inspection, fault finding dg set above 100 k up to 150 km , preventive maintenance dg set 15 to 20 kva , preventive maintenance dg set 22 to 25 kva , preventive maintenance dg set 30 to 45 kva , preventive maintenance dg set 63 kva , replace banjo bolt with copper sealing washers , replace hand primer with valve kit , provide fix flexible trapezoidal v belt , replace fuel pipe tank to filter up to 2m , replace fuel pipe filter to pump , replace overflow return pipe nozzle to tank , replace battery terminal cables 18 sq mm 1 mtr length , replace blower fan bearings air cooled dg , replace water pump assembly complete , supply fix 12v dc stop solenoid , top up lubricating oil as recommended , replace heavy duty air filter 15 to 30 kva , replace heavy duty air filter 32.5 to 40 kva , replace heavy duty air filter 50 to 63 kva , repair self starter motor up to 63 kva , replace self starter pinion gear up to 1350 watt capacity , replace 12v dc self starter solenoid switch , replace field coils stator coils , replace armature set , repair calibrate fip two nozzle engine , repair calibrate fip three nozzle engine , repair calibrate fip four nozzle engine , check rewire dg starting instrument panel , supply digital rpm cum hour meter with vaf , provide led indicating lamp , replace panel mounting voltmeter 0 to 415v , provide push buttons , provide tubular glass fuse with holder , replace avr for 15 kva to 63 kva alternator , repair battery charger alternator , supply fixing 12v 100ah smf battery , supply fixing 12v 130ah smf battery , supply install 12v 10a smps charger , clean repairing descaling radiator 15 to 30 kva , clean repairing descaling radiator 32.5 to 40 kva , clean repairing descaling radiator 63 kva
Tender For corrigendum : purchase of tanche - lab equipments for physics lab in basic engineering department - purchase, decade resistance box resistance box 12 month warranty (dial type) -manganin coil- 2 dials, wheatstone bridge kitseries arm: four decade dials in steps of thousands, hundreds, tens, & units of ohms. ratio arm: the ratio arm of the bridge is capable of selecting multiplying factor of 0.001, 0.01, 0.1, 1, 10, 100, 1000 for resistance measurements. two press keys are provided, one marked b is for battery & one marked g is for galvanometer one toggle switch is provided for internal battery a sensitive galvanometer is provided in the bridge., ohms law verification kitbattery eliminator-3a, (2,4,6,8,10,12 v), tubular rheostat 20-3.3a, one way plug key, analog type dc ammeter (0-2a), voltmeter (0-5v), standard resistance coil of 1, 2 ohm (2-set) wound on a wooden bobbin
Tender For :purchase of chemistry laboratory equipment for basic engineering department - purchase of chemistry laboratory equipment for basic engineering department, hot plate: top plate material: cast iron ; plate size: minimum 8 inch diameter;power rating: 2000 w ; temperature range: ambient to 200 c minimumthermostatic temperature control: required; power supply: 220 240 v ac, 50 hz, ic regulated battery eliminator: ic regulated, input: 230v ac; output: 0-12v dc in steps of 2v; capacity: 1a or 2a., ammeter: dc (0 - 2 amp), voltmeter: dc voltmeter; range 10 v, analog, galvanometer: moving coil type, 30-0-30 scale, unbranded with bhel ; specification-sensitivity 0.143mm/v, water distillation unit: output capacity: 4 litres per hour (lph); ph value: 5.5 to 7.0 ; conductivity (raw water distillation):3.0 4.0 s/cm or less ; glassware material: borosilicate 3.3 glass (pyrex/duran equivalent); heating elements: silica-enclosed quartz heaters or chromium-plated element variants; power supply: 220 240 v ac,50 hz / 60 hz, single phase; automatic water level cut -off, electro analytical balance: load capacity: minimum 500 g; readability: 0.01 g; linearity: 0.02g; display: lcd/led; tare function: required; top pan type; power supply: 220 240 v; ac, 50 hz, electric bunsen burner: electrically operated, energy regulator/ control knob operating temperature 800 c ; body: stainless steel, power supply source: corded, electrically operated; energy regulator/ control knob, operating temperature 800 c ; body: stainless steel, power supply source: corded electric, supplied with a heavy-duty, heat-resistant, electric, supplied with a heavy-duty, heat -resistant, digital balance: weight 500g, accuracy 0.01g, top pan. tare function, caliberation- automatic external display type: led