Get complete information related to latest Female Contact Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Female Contact Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Female Contact Tenders.
Tender For supply of uhv deposition chamber - uhv chamber specification (vacuum better than 2 10-9 mbar uhv) chamber overview spherical (diameter 14 ) or equivalent square shaped uhv chamber with support frame equipped with three (3) x 2-inch magnetron sputtering sources. all cf flanges and uhv viewports/ss blanks, three (3) x 2-inch magnetron sputtering sources. each sputtering source has an individual gas inlet line for process gases. all cf flanges., substrate holder : diameter: 2 inches; heating molybdenum heater capable of heating substrate (a) from room temperature (rt) to 800 c during rotation and (b) from room temperature to 1000 c without rotation. rotation: substrate holder can rotate continuously, driven by a stepper motor. variable speed from 0 to 10 rpmmovement: up / down vertical movement of total 25mm to adjust substrate position during deposition sputtering geometry: one sputtering source mounted parallel to the substrate surface, tilt adjustable. two sputtering sources mounted confocally at an angle relative to the substrate. base pressure: lower than 2 10 mbar (ultra-high vacuum)., vacuum pumping system: turbo molecular pump: pfeiffer hipace300 / edwards next 300 / leybold turbovac 350i with cf100 flange or equivalent with integrated controller, ion pump with controller: included to maintain uhv vacuum levels and provide clean pumping., backing pump: pfeiffer hiscroll 12 / edwards nxds 15i / leybold scroll vac 15 plus or equivalent dry scroll pump used to back tmp, gate valves : one cf100 and one cf150 manual gate valves for isolating the chamber from the pumping systems as well as throttling, vacuum gauges and measurement: one cold cathode gauge with readout capable of measuring vacuum pressures down to1 10-10 mbar for precise uhv monitoring., one capacitance manometer gauge with measurement range from 1 10-1 to 1 10 mbar for accurate pressure reading during deposition phase, gas delivery system: two independent mass flow controllers (mfcs):a. one mfc (0-100 sccm) for argon gas feeding to all three sputtering sources via high vacuum valves.b. one mfc (0-100 sccm) for nitrogen gas feeding directly into the chamber with its own high vacuum valve.gas lines for ar and n2 are physically separated to avoid cross-contamination., chamber access and viewports: 1. two view ports installed on the chamber, each equipped with manual shutters. 2. access ports for gauges, pump, gas inlet and few spares for future upgradation., baking capability: entire chamber designed to bake-out at 150 c to reduce contamination and out gassing during operation, cooling capability : water manifold with flow switch / flow meters, near uhv chamber specification: chamber overview: spherical (diameter 14 ) or equivalent square shaped uhv chamber with stand., three 2-inch magnetron sputtering sources, each with individual gas inlet. all cf flanges and uhv viewports/ss blanks., substrate holder: a. diameter: 2inches; heating : molybdenum heater capable of heating substrate (a) from room temperature (rt) to 800 c during rotation and (b) from room temperature (rt) to 1000 c without rotation b. rotation : substrate holder driven by stepper motor. variable speed from 0 to10 rpmmovement: up / down vertical movement of total 25mm to adjust substrate position during deposition sputtering geometry: one sputtering source mounted parallel to substrate surface (tilt able preferred). two sputtering sources mounted confocally at an angle. base pressure : lower than 5 10 mbar (near uhv)., vacuum pumping system: turbo molecular pump : pfeiffer hipace 700 / edwards next 730 / leybold turbo vac 900 ix or equivalent with cf100 flange and integrated controller, suitable for near uhv vacuum., backing pump: pfeiffer hi scroll 12/edwards nxds15i / leybold scroll vac 15 plus or equivalent dry scroll pump used to back tmp, gate valves: one cf150 manual gate valve to isolate / throttle chamber from pumping system, vacuum gauges and measurement: cold cathode readout capable of dis
Tender For purchase of equipments for ece department - function generator frequency range: 0.1 hz to 5 mhz display: 4 to 6 digit led display output waveforms: sine, triangle, square, pulse, ramp . amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v, strain gauge trainer kit ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual., temperature measurement kit sensors: rtd (pt-100), thermocouple (fe-k/j-type), and/or thermistor (ntc). display: 3 digit led/lcd digital display (typically 200 mv fsd). temperature source: portable water kettle or heater block. signal conditioning: on-board circuitry for amplification, linearization, and cold junction compensation. test points: multiple 2 mm / 4 mm banana sockets for monitoring input/output signals. power supply: 230 v ac, 50 hz, single-phase. accessories: glass thermometer, 10 k ntc thermistor probe, k-type thermocouple probe, patch cords and user manual., cathode ray oscilloscope bandwidth: dc to 30 mhz (-3 db) - sensitivity: 1 mv/div to 5 v/div - display modes: ch1, ch2, dual (chop/alt), add, sub - timebase: 0.2 s/div to 0.5 s/div (essential for slow bio-signals) - magnification: x 10 sweep magnifier - triggering: alt triggering, auto, norm, - tv-v/h with source selection (ch1, ch2, line, ext). - input impedance: 1 mohm || 25pf - included accessories: two 60 mhz passive probes, power cord, and user manual
Tender For corrigendum : supply of seqstudio cartridge v2 2 boxes , seqstudio cathode buffer container cbc , integrated capillary protector icp , cathode buffer container reservoir septa 20 pack , 96 well plate septa 20 pack , microamp optical 96 well reaction plate , septa, 96 well 20 pk , hi di formamide 4 x 5 ml , bigdye terminator v3.1 cycle sequencing kit 100 reactions , bigdye xterminator kit 2ml each , exosap it 500 reactions ea , nuclease free water not depc treated , adhesive pcr plate seals 100 pc , genescan 600 liz size standard v2.0 800 rxns , 5 inch labeled or unlabeled primer pairs 10000 pmole , truemark msi assay , dpyd , human fwd primer ds , human rev primer ds , human fwd primer hplc , human rev primer hplc , oncomine myeloid research assay , oncomine focus assay each , oncomine comprehensive v3m combo kit , oncomine brca assay manual kit , ion xpress barcode adapters 1 96 , ion ampliseq lib kit plus , ngs reverse transcriptase kit , ion 510 ion 520 ion 530 kit chef 1 sequencing run per initialization , ion 530 chip kit , ion 520 chip kit , ion 510 ion 520 ion 530 kit chef 2 sequencing runs per initialization , ion 540 chef kit , ion 540 chip kit , ion 16s metagenomics kit , ion plus fragment library kit each , ion ampliseq microbiome health 48 rxn or pnl in 540 chip , alltype fastplex 11 loci kit , ion 520 ion 530 ext kit chef , oncomine cftna lung assay , tag sequencing bc set 1 24 , magmax cellfree total na isolation , ion xpress barcode adapters 1 16 kit , ion xpress barcode adapters 17 32 kit , ion xpress barcode adapters 33 48 kit , ion ampliseq library kit plus , microamp optical 96 well reaction plate , microamp fast optical 96 well reaction plate , microamp optical adhesive film , microamp adhesive film , microamp compression pad , ion library taqman quantitation kit , qubit dsdna quantification assay kits 500rxn , naoh 1n , tris hcl ph 8,1m , qubitrna br assay kits , qubit fluorometer system verification assay kits , qubit rna iq assay kits , qubit rna hs assay kits , qubit rna xr assay kits , magmax cell free dna isolation kit
Tender For supply of set of male and female assembly of auxiliary converter of 3 phase locos. set consists of 2 items. (1) male contact assembly as per abb id no. hiet 430209r 0001, qty./set-m 01 no. (2) femalecontact assembly as per abb. hbta 312496r 1002 qty./set-02 nos. [ warranty period: 30 months after the date of delivery ]