Get complete information related to latest Female Contact Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Female Contact Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Female Contact Tenders.
Tender For bid to ras corrigendum : tender for supply of burner tilt power cylinder as per boq line item 1 , mandatory spares as per boq line item 2 , burner tilt power cylinder as per boq line item 3 , mandatory spares as per boq line item 4 , burner tilt power cylinder as per boq line item 5 , mandatory spares as per boq line item 6
Tender For supply of spares for lt switchgear panels under chp section ctps dvc - power contractor(ac) with 1no aux. contact coil voltage 240v ac type- lc1-d633-63a, lt module incoming, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of upto 100a induvidual pole, make-c&s, lt module incoming, male+female lyra contacts of 250a induvidual pole, make-c&s, lt module outgoing, male+female lyra contacts of 250a induvidual pole, make-c&s, power contactor 3pole ac, 80a, coil voltage=240v ac , ui=660v, refernce lc1-d803u5a60, power contactor with coil voltage 240/220 v ac,rating-32a ,type-tc1d3210-m5,make-c&s(psl-5), contactor ac power 3p, ac, 150 a, coil voltage=240v ac, vi=660v reference no. lc1-f-dp150, 415v ac, 185a power contactor with 2 no + 2 nc aux. contact with 240v ac coil, ty: pe lc1-, f185a+lx1-fg+la1-d22, make (c & s), tp) switch fuse unit with 1no+1nc aux, type cssdf32d3 rating-32a, switch fuse unit (tp) with 1no+1nc aux.cont. type:-cssdf125d3,125a, switch auxiliary 14 way(7 no + 7 no) for acb rating upto 2000-3200a, reference cs-axh-7a7b-220, relay thermal overload direct mounting relay setting range 0.63-1a ref tr2-d09305, thermal over load relay direct mounting relay setting range 2.5-4a ref- lr1-do9338, bi-metallic o/l relay, rating-48-65a,make-c&s,type-tr2d65359 (psl-6), relay thermal overload direct mounting relay setting range 17-25a ref tr2-d25322, control relay 10a, contact arrangement 2no+2nc, refernce tca3-dn22md, (coil voltage 220dc), control relay 10a, contact arrangement 4no, refernce tca3-dn40md, (coil voltage 220dc, control relay 10a,4 no ac referance tca2-dn40v5, coil voltage 240 v ac, 240v, 10a, auxiliary contactor with 2 no + 2 nc contact type: ca2d1229, make (c & s), closing coil limit switch ,product code: cclimsw, power contactor 3pole ac, 16a, coil voltage=240v ac , ui=660v, refernce lc1-d173u5a60, control relay 10a, contact arrangement 3no+1nc, coil voltage 240ac; reference tca2-dn31, switch disconnector fuse unit,250a,tpn, type:cssdf250d3n+cssdfzx33, 63a, triple pole switch fuse unit type cssdf63d3n make (c & s), overload relay (make:c&s) range:38-50a type:lr1-d63357., contactor power 3p ac 115a, coil voltage 240v ac, vi=660v, ref.- lc1-f115v or equivalent, contactor ac power 3p, ac, 18 a, coil voltage=240v ac, vi=660v reference no. tcid1810, thermal over load relay type lr1 direct mounting relay setting range 5.5-8a,refrencr lr1-, d09312, ui-660v, relay thermal overload direct mounting relay setting range 5.5-8a ref tr2-d09312, relay thermal overload type lr1 direct mounting relay, setting range 57-66a ref: lr1-d63361, vi=660, thermal overload relay direct mounting ralay setting range 1-1.6a, relay thermal overload setting range 0.63-1a ref: lr1-d09305 vi=660, add on block 2 no ref: ta1-dn20, add on block 1 no+ 1 no ref: ta1-dn11, add on block 2 no+ 2 no ref: ta1-dn22, relay thermal overload direct mounting relay setting range 12-15a ref tr2-d15321, control relay 10a, ac referance tca2-dn22v5, coil voltage 240 v ac, acb(tp), electrically oprated drawout type, without realeases type -ah-8d-cs- 800a, in=800a,, ue=415v,ui=1000v, f=50/60 hz,icu=ics= 50 ka, ics(1s)=50k
Tender For rate contract for supply, installation, testing and commissioning of various materials required for maintenance of 33/11 kv receiving stations for smooth running of power supply from receiving stations under the jurisdiction of std pulwama for the fy 2026 27 - installation,testing and commissioning of 11 kv vcb panel board 12 kv, 1250a, 25 ka, (incommer), installation,testing and commissioning of 11 kv vcb panel board 12 kv, 1250a, 25 ka, (outgoing, installation,testing and commissioning of 33 kv vcb (36 kv, 1250a, 26.2 ka, outdoor type), dismantalling of old, 11kv vcb panel complete, 33kv c&r panel complete, installation,testing and commissioning of of 33 kv c&r panel, supply, installation,testing and commissioning of fresh 11kv c.t confirming to iec 60044-1-2000 standards suitable for following 11kv vcb with ratio 800-400/5-5-5a, 600-300, 400-200, 100-50 of make like alsthom, easun reyroll,vijay,sudhir,electric field,crompton greeves,allind,abb,pascal,hartek,stelmec etc by way of replacement of damaged/burnt out 11 kv c.t, installation,testing and commissioning of fresh 11kv c.t by way of replacement of damaged/burnt out 11 kv c.t of same ratio,type,make and class already installed in panel (material to be provided by the department) (for 11kv vcb panels), supply,installation,testing and commissioning of 11kv p.t confirming to iec 60044-1-2000 standards (for 11kv vcb panels) by way of replacement of damaged/burnt out 11 kv p.t, installation,testing and commissioning of fresh 11kv p.t by way of replacement of damaged/burnt out 11 kv p.t of same ratio,type,make and class already installed in panel (material to be provided by the department) (for 11kv vcb panel), supply,installation,testing and commissioning of fresh male contact (set of 06 pcs) of following 11kv vcb of make alsthom, easun reyroll,vijay,sudhir,electric field,crompton greeves,allind,abb,pascal,hartek,stelmec etc by way of replacement of damaged/burnt out male contact set of same composition,type,make and class already installed in 11kv vcb panel, supply,installation,testing and commissioning of fresh femalecontact (set of 06 pcs) of following 11kv vcb of make alsthom, easun reyroll,vijay,sudhir,electric field,crompton greeves,allind,abb,pascal,hartek,stelmec etc by way of replacement of damaged/burnt out male contact set of same composition,type,make and class already installed in 11kv vcb panel, installation,testing and commissioning of fresh male/femalecontactof following 11kv vcb by way of replacement of damaged/burnt out male contact set of same composition,type,make and class already installed in 11kv vcb panel, supply,installation,testing and commissioning of 11kv vacuum interruptor by way of replacement of damaged/burnt out 11kv vacuum interruptor of same composition,type,make as already installed in 11kv vcb panel (1250amps) of following make, alsthom make, easun reyroll make, stelmec, vijay make, sudhir make, electric field, crompton greeves, allind, abb make, pascal make, hartek make, supply, installation,testing and commissioning of 33 kv vacuum interruptor for 33kv vcb panel by way of replacement of damaged/burnt out of following make, alsthom make, crompton greeves, abb make, megavwin make, fixing of fresh 33kv / 11kv vacuum interruptor by way of replacement of damaged/burnt out 11kv vacuum interruptor of same composition,type,make already installed in 11kv vcb panel (material to be provided by the department), supply, installation,testing and commissioning of numerical/digital relay (a.c &d.c),type,make and class already installed in panel (3oc+1ef).all relays shall conform to the requirements of is:3231/iec-60255 and iec-61850 of operating voltage 30-36volts by way of replacement of damaged/burnt out of make, asida adr241b make, cg make, abb 615 make, abb rej601 make, fixing , testing and commissioning of numerical/digital relay of types, supply,installation,testing and commissioning of of panel insulator (supporting insulator for bu
Tender For corrigendum : supply of - screen protector, mobile folding privacy screen / ward screen, oem spares for automobiles, projector screen (v2), wedge wire screen, rotary microtome, spares tyre for tyre coupling, spares for tripper and apron feeder, dark glass for welder's screen, spares for coal mills of thermal power stations (gsecl) - screen spares for ccl washeries under mb 2025 26
Tender For corrigendum : supply of kirloskar make pumps spares on door delivery basis at hbl plant sugauli, east champaran, bihar - supply of kirloskar make pumps spares at hbl plant sugauli as per the technical specification mentioned below:, bare pump model db 100/40 or ib 100/40xe,ci impeller, wearing plate de sp-4l make kirloskar, screw counter sunk m12 1.75 50 mm lft ss make kirloskar, nut hex head (ms) sp-4l m12 1.75, sewage dewatering submersible pumpmodel eterna 15000cw 4plpower rating 15 kw / 20 hpdelivery size 150 mmrated voltage 380 vspeed 1440 rpmmax solid handling size 45 mmhead range 6 m to 20 mflow 288 m /hr to 400 m /hrimpeller cidelivery casing cimotor body cipump shaft cspump make kirloskarsuitable cable for eterna 15000cw 4pl pump 30 m with star delta panel., self-priming pump coupled with ie2 motor, starter, and cablemodel sp4l + with 12.5c4 motor power rating 9.3 kw / 12.5 hpsuction 100 mmdelivery 100 mmrated voltage 415 vspeed 1450 rpmimpeller dia 292 mmhead range 10 m to 26 mflow range 41 lps to 16 lpsmaterial of construction (moc):impeller cidelivery casing cimotor body cishaft c40sealing gland packingpump make kirloskarstar delta panel for sp4l pumpsuitable cable for sp4l pump 30 m.
Tender For corrigendum : procurement of spares for 1kwhf transmitter, transponder iff, 5kw transmitter st 5000 and par p2080c radar - 5 kw line flattner model elmer ati atu-5000, r/e unit (with pps), service power supply, antenna, twt assy, hammer
Tender For corrigendum : procurement of elgi compressor critical spares for fgd area ntpc kudgi - power supply,00890100r,compressor, temp trans,008979028,elgi, temp trans disch,008979029,elgi, ai module,b011606600003,elgi, pr transmitter,00897902r,elgi,-1-6bar, pressure switch,b002200510001,elgi, ai module,008901016,elgi,compressor, i/o relay,008901014,elgi,ml1400dc