Tender For supply of detector removal tool as per atc , loop card micro module as per atc , serial esser net interface modules as per atc , network card essernet series 2 nw card 64 k as per atc , main firealarmcontrolpanels cpu card for facp as per atc , iq8 repeater panel as per atc , heat detector as per atc , otg multisensor fire detector co iq8quad with isolator as per atc , o2t multisensor fire detector iq8quad with isolator as per atc , otblue multisensor fire detector iq8quad with isolator as per atc , optical smoke detector iq8quad with isolator as per atc , controller for lhdc as per atc , esserbus transponder rzt 24 v as per atc , flame detectors as per atc , usb cable ab and serial connecting cable as per atc
Tender For corrigendum : supply of loop card for firealarmcontrolpanel , monitor module addressable type monitor module. , control relay module addressable control relay module. , optical cum thermal detector intelligent addressable multi criteria optical cum thermal detector wit , optical cum chemical detector intelligent addressable type, maintenance easy optical cum chemical de , response indicator , break glass type manual call point intelligent addressable break glass type manual call point. , sounder or hooter addressable type loop powered /external powered sounder or hooter with multiple to
Tender For supply of plasticized pvc tapes with non-thermosetting adhesive for electrical purpose (v2) isi marked to is 7809 (part 3/ sec1) (q2) , xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , canvas fire hose with male and female coupling 63mm dia x 15 mtr long , ms fire hook with babu standard length , ms fire double hose box of size 800x600x250mm , ms fire hose reel drums 3 or 4 inch for 30 mtr hose , ms fire hose reel drums 1 inch for 30 mtr hose , ms fire hose reel heavy duty 20mm dia x 30 mtr long for hose , fire hydrant landing valves gun metal single outlet 63 x80 mm dia flanged pipes , fire hydrant landing valves gun metal double outlet 63x80 mm dia flanged pipes , non return valve 150 mm dia pn 1.6 , non return valve 100 mm dia pn 1.6 , butterfly valve 150 mm dia , butterfly valve 100 mm dia , foot valve 150 mm dia , foot valve 100 mm dia , firealarmcontrolpanel conventional type 8 zone , firealarmcontrolpanel conventional type 12 zone , firealarmcontrolpanel addressable type up to 99 loop , manual call point , electronic hooter , heat detector automatic reset type , pvc insulation tapes size width 20 mm length 10 mtr , hydrant key as per isi * /bid number : gem/2026/b/7704220 + /dated: 24-06-2026 ' ' / bid document 1 / 25
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf controlpanel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp