Web Analytics Made Easy - StatCounter

Fixed Contactor Tenders

Get complete information related to latest Fixed Contactor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fixed Contactor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fixed Contactor Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :41022029 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For procurment of sfu - welding receptcles, switch fuse unit complete box with sfu-32a-tpn (cylendrical fuse link) enclosure material:thermoplastic polycarbonate. degree of protection for empty enclosure: ip65 (iec 60529. mechanical impact strength for empty enclosure: ik08 (iec 62262. system voltage: 415v, 50 hz, ac. mounting type : wall. recommended cable size: incoming: 4c x 25 sq.mm al ar cable, outgoing: 4c x 10 sq.mm cu cable suggested make- cape electric or c&s or hensel or schneider, switch fuse unit complete box with sfu-63a-tpn (cylendrical fuse link) enclosure material:thermoplastic polycarbonate. degree of protection for empty enclosure: ip65 (iec 60529. mechanical impact strength for empty enclosure: ik08 (iec 62262. system voltage: 415v, 50 hz, ac. mounting type : wall. recommended cable size: incoming: 4c x 35 sq.mm al ar cable, outgoing: 4c x 16 sq.mm cu cable suggested make- cape electric or c&s or hensel or schneider

CTN :41002886 Due date: 31 Jul, 202531 Jul, 2025 NA
Tender For 20bslc002 spares of various types of contactor and relays : - fuse carrier , electronic protection relays 12 5a 50a , red ind lamp complete unit for 230 v with built in resistor , green led(wide band led pilot light compl.unit 42 to 240 v ac , bimetal overload relay having relay range 25 36 a , d1 d2 d3 relay 4 no 4no 220v 380 ic 6 a 500 , motor protection relay , amber led indicating lamp with wide band voltage 42 220v , 6 way double door mcb distribution board for 3 phase incom , 1nc rear connection auxiliary contact for push button , contactor 3 pole relay 10a 230vac 50hz , timer range 3 to 12 sec , bimetal overload relay having relay range 4 6 3a , 1no rear connection auxiliary contact for push button , contactor 70a ac3 110v 50hz 2no 2nc , relay overload 0 25 1a , relay overload 8 16a three pole , bimetal overload relay having relay range 0 63 1a with adapt , bimetal overload relay having relay range 2 5 4a , red led indicating lamp with wide band voltage 42 220v , power distribution board 10 way db 415v 3ph , bimetal overload relay having relay range 20 32a

State Government

CTN :40985778 Due date: 28 Jul, 202528 Jul, 2025 1.80 Crore
Tender For purchase of sports physiotherpy lab equipments - focused shockwave therapy the device should be suitable for musculoskeletal use. should be a focused shockwave based on piezo mechanism. should have multi array type piezo electric hand piece. should have accuracy of the shock wave generation cycle(frequency)0~8 10% should have software-based operating system the unit should have large color touch screen for ease of operation. the unit should have accuracy of the operating frequency 0~7000shock 10% the unit should have maximum energy density 0.702 m j/ (when setting at 23 levels) 15% should have shock wave penetration depth 40 20%. should have maximum focus size. 78 1.78 15.81 20% should have maximum pressure 44.01 0.65 mpa the unit should be supplied with piezo hand piece and elastomer gel padas of 8 different sizes, 5mm, 10mm, 15mm, 20mm, 25mm, 30mm, 35mm, and 44mm. the life span of hand piece should be of up to 10 million shocks. should be supplied with trolley with castor wheels. dimension of the device should be approximated 500mmx700mmx 1000mm should have ce or usfda certified., high laser therapy should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser should be class iv high level laser therapy system should have a real-time operating system technology should have maximum laser power output of 15 watts should have wavelengths of 810 nm & 980 nm should have an aiming beam of 650nm, should have 2 operating modes: continuous wave or pulsed applicate and piece should have embedded finger switch and light, should have a technology to customize patient treatment based on conditions, body area, body type, skin type, chronicity and absorption characteristics applicator should have a fused silica composition massage ball at the point of contact of applicator and skin. pulse frequency: 2, 10, 20, 100, 200, 500, 1000, 2500, 5000 & 10000hz pulse duration: 50% duty cycle at any given pulse frequency setting, should have a 10 hd display touch screen with password protection to reach the home screen should be supplied with 2nos. of laser protection glasses power: 100-240v, 50-60 hz the unit should be supplied with 5 different types and sizes of treatment heads (large cone, large massage ball, flat window, small massage ball, and small cone. the unit should have inbuilt battery. electrical safety class: class i, type b weight should not exceed 4 kilograms (main unit; without applicators & accessories. must have class iii also., combination therapy machine with vaccum should have 3 independent electrotherapy channels, one ultrasound channel should provide multiple clinical waveforms including interferential (2 and 4 poles and isoplanarvector), tens (asymmetric biphasic &symmetric biphasic), han, russian, vms, surged(rectangular &triangular), hvpc, microcurrent, galvanic (continuous, interrupted and low level),rabert & dia dynamic cpid/cpiso should have independent parameter adjustments for each channel including intensity, frequency, duty cycle, vector scan, channel mode, phase duration, ramp, cycle time and treatment time based on waveform should have maximum output intensity up to 140ma should have constant current and constant voltage modes should have 2 colour coded lead wires for easy picking of selected channels should have suggested electrode placement guidelines ultrasound should offer 1 and 3 mhz frequencies should have the ultrasound bnr of 5:1 or lesser should be supplied with one 5cm applicator head should have pulsed & continuous frequency modes (10%, 20%, 50% & 100%) should have variable duty cycles of 16 hz, 48 hz &1 bb 00 hz should have facility to indicate applicator uncoupling should be able to use electrotherapy and ultrasound independently and also in synchronizedcombination of electrotherapy and ultrasound, where ultrasound head functioning as bothultrasound head and electrode should have minimum 7 high resolut

Central Government/Public Sector

CTN :40991222 Due date: 07 Aug, 202507 Aug, 2025 NA
Tender For supply of motor protection circuit breaker (mpcb) for compressor unit and heater unit, current rating 7-10 amp, thermal release range 10-16 amp, class-10, breaking capacity 10ka, 3-pole, voltage rating 415 v ac, conforming to is/iec 60947-2; conforming to rdso spec. no. rdso/pe/spec/ac/0184-2015 (rev. 1); suitable for use in switchboard cabinet of lhb type ac coaches.accepted make & cat. /model no.: rdso-approved make and model as per serial no. 39 of rdso letter no. el/7.1.108/mssbc dated 17.09.2021 or any other rdso-approved make

Central Government/Public Sector

CTN :40946160 Due date: 14 Jul, 202514 Jul, 2025 NA
Tender For supply of led based driver and assistant desk illu [led based driver and assistant desk illumination lamp as per clw specn. no. clw/es/3/0042 alt.d. technical specification: 1) operating voltage 18 to 30 v dc, with normal voltage of 24 vdc. 2) high and low glow switch has to be provided.3) the lamp unit shall have inbuilt reverse polarity, over voltage trip, spike and surge protection.4) mechanically the housing shall be as per clw spec. no. clw/es/3/0042. alt.d]

Central Government/Public Sector

CTN :40946195 Due date: 21 Jul, 202521 Jul, 2025 NA
Tender For supply of over voltage protection (ovp) testing unit

Central Government/Public Sector

CTN :40918261 Due date: 28 Jul, 202528 Jul, 2025 NA
Tender For supply of suppy of 1.15 kw (ieh-15a) high frequency mosfet based solid state power source having fr equency of 30-100 khz and max input current as 32 amp. it includes following items: a) mosfet based, wate r cooled high frequency induction heating power source with safety indicators and protection for over curr ent, water lack, water flow phase fail etc. b)operating voltage: 220v 50hz c) dm water circulation unit. [ warranty period: 30 months after the date of delivery ]

CTN :40870533 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For supply of hf type fuse, rating- 4a, motor protection relay 415v ac, 50hz, 240v ac,50hz,, ps 3-8rg pipe, 2 x pg13.5 suitable cable dia 5-14mm, blower complete with motor. model vr-50-2-1 - 80 m3- hr,, power contactor coil voltage 120v ac, with inbuilt 1no aux, power contactor/1no-50hz-110v, add on contact 2no-2 nc, power contactor for mnx18 contactor,coil 240v ac,50hz, indicating lamp 120vac-50hz, green colour, led type, indicating lamp 120vac-50hz, green colour, led type, indicating lamp 120vac-50hz, white colour, led type, ammeter range - 0-150a dc, size 72x72, type no. smi-72, voltmeter range 0-250v dc, size 72x72, type no. smi-72, mpr300bb010, 110vac-50hz, relay contacts-1no 1nc-1-2.75a, mpr300bb040, 110vac-50hz, relay contacts-1no 1nc-4-11a, macerator, pump only, cover, suction chamber, rotating knife, macerator compl, nut for flap valve, flange w-connecting pipe dn50, screw,m10x170, fan, fan cover, l-coupling, screw,m8x20, screw,m8x20, screw,m8x35, nut,m5, washer,m6, screw,m6x16, o-ring, sealing ring, o-ring, rubber flap, orifice, shaft seal i 35 mm, ball bearing, ball bearing, flow orifice, indicating lamp red colour lens, 120v, indicating lamp green colour lens, 120v, voltage monitoring relay three phase, ammeter 0-100a, dc suitable external shunt 50mv,size 72 72mm, voltmeter range 0-250v dc, size 72x72, type no. smi-72, solenoid valve 1-4, fd valve w/vpc-v, complete, sheet and cover, comfort, release button, level controller gwt, y-strainer, 1-2, pvc, sched 80 (threaded), valve, 1 swing check, pvc, control relay 5a,relay with 230v ac retaining clip, solenoid valve 1 2-2 way direct acting, pump fresh water (hydrophore pump),, pump centrifugal monoblock pump in moc ss316,size-32 x 32mm, controller, flow, 0.5 gpm, control relay 110vac,50-60hz tesys k2 no 2 nc, overload relay 4.0 6a with spp, lrd-10, gasket, neoprene, for 1-2-150 flange, gasket, neoprene, for 1-150 flange, gasket, neoprene, for 1-1-2-150 flange, gasket, neoprene, for 2-150 flange, gasket, neoprene, for 3-150 flange, gasket, neoprene, for 4-150 flange, valve,solenoid, 1-4, brass, 120v (mounted at control panel), 1 hp motor(tefc) - baldor ip-56, seal kit ( mechanical seal, bushing, and o-ring), 5-8 coupling flange(pump side), axial cutter, radial cutter, impeller washer, cutter ring, 17-4ph, 7-8 coupling flange(motor side), impeller, dechlor replacement tube, santoprene, 2 pk, dechlor replacement tube, santoprene, 5 pk, relay, control, 24 vdc, din, 1pdt, relay, power, 40adc, dpdt, orifice plate, titanium, for 1 t-u ball valve (unsized), rod all thread, 1-2 x 4 brass, bolts, 5-16, 316 ss, washer, flat 3-8 316 ss, book cell assembly, 4-6-8m, complete cell unit, sealant, silicone, handle, chrome plated, pvc true union ball valve socket - 1-2, pvc true union ball valve socket - 3-4, pvc true union ball valve socket - 1, pvc true union ball valve socket - 1 1-2, pvc true union ball valve socket - 2, pvc true union ball valve socket - 3, pvc one piece flange socket - 1-2, pvc one piece flange socket - 3-4, pvc one piece flange socket - 1, pvc one piece flange socket - 1 1-2, pvc one piece flange socket - 2, pvc one piece flange socket - 3, pvc one piece flange socket - 4, pvc check valve - 1 1-2, pvc check valve - 2, pvc tee socket - 3-4, pvc tee socket - 1, pvc tee socket - 1 1-2, pvc tee socket - 2, pvc y strainer - 1-2, pvc cap fipt - 1-2, pvc female adapter socket x esr fjpt - 1-4, pvc female adapter socket x esr fjpt - 1-2, pvc female adapter socket x esr fjpt - 3-4, pvc female adapter socket x esr fjpt - 1, pvc female adapter socket x esr fjpt - 1 1-4, pvc female adapter socket x esr fjpt - 1 1-2, pvc female adapter socket x esr fjpt - 2, pvc male adapter socket x mipt - 1-2, pvc male adapter socket x mipt - 3-4, pvc male adapter socket x mipt - 1, pvc male adapter socket x mipt - 1 1-4, pvc male adapter socket x mipt - 1 1-2, pvc male adapter socket x mipt - 2, pvc 90 deg. elbow socket - 1-2, pvc 90 deg. elbow socket - 3-4, pvc 90 deg. elbow socket - 1, pvc

Central Government / Public Sector

CTN :40867326 Due date: 17 Jul, 202517 Jul, 2025 NA
Tender For motor protection circuit breaker (mpcb) for compressor unit & heater, current rating 7-10 amps, therma l release range 10 to 16 amp, class 10, breaking capacity - 10 ka, 3 pole voltage rating 415 v ac, 01 no + 01nc auxi liary contacts for lhb ac switch board cabinet as per rdso spec no. rdso/pe/spec/ 0184-2015 rev 1or latest and rd so lr.no el/7.1.108/mssbc dt:17/09/2021. acceptable makes: siemens model.no. 3rv2011-1ja10, l&t model.no. st41 8980000, schneider model no. gv2me14, abb model.no ms116-10, eaton model no.pkzm01-10 and legrand only accep table as per above spec. warranty period: 30 months from the date of supply. [ warranty period: 30 months after the date of delivery ]

Central Government / Public Sector

CTN :40867328 Due date: 17 Jul, 202517 Jul, 2025 NA
Tender For motor protection circuit breaker (mpcb) for condenser fan unit, current rating 1.6 to 2.5 amps, class 10, breaking capacity - 50 ka, 3 pole voltage rating 415 v ac, 01 no + 01nc auxiliary contacts for lhb ac switch board ca binet as per rdso spec no. rdso/pe/spec/ 0184-2015 rev 1or latest and rdso lr.no el/7.1.108/mssbc dt:17/09/202 1. acceptable makes: siemens model.no. 3rv2011-1ca10+3rv2901-1e, l&t model.no. st418950000, schneider model no. gv2me07, abb model.no ms116-2.5 and eaton model no.pkzm01-1.6+nhi-e-11-pkz0 only acceptable as per above spec. warranty period: 30 months from the date of supply. [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up