Get complete information related to latest Fixed Contactor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Fixed Contactor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Fixed Contactor Tenders.
Tender For supply of wiper arm and blade , wiper arm , blade assy wiper , wiper blade amb , cable complete , rubber hose , light assy indicator , door bedding , hose air , main line switch , door glass channel , back window strip
Tender For purchase of biomechanical lab - force platedimensions (w x d x h) in mm : 600 x 400 x up to 50 number of axes for force measurement: all 3 axes. x,y,z plate should be portable in naturesensor type: piezoelectricsampling frequency-(hz) =1000 hz or more force measured on each axis-fx,fy: 2,000 newton or more, fz: 10,000 newton or more hysteresis- (%fso): 0.5 linearity (%fso) 0.5 crosstalk (%) : 2water resistance rating: ip 50 or better.should be inclusive of installation.should be supplied with carrying case for 2 plates and noise free ups for on-ground assessment. the carrying case should be strong and sturdy.should be able to accommodate portable force plate 9286 ba, daq box 5695 and connecting cablesshould be able to protect the equipment from rain, impact and dust, should have rollers to move easilyshould be able to accommodate an ups also., isokinetic dynamometershould be able to access/test various joints in isolation should be able to meet requirements to test sports personsshould be able to test in different resistance modes such as isokinetic (concentric-concentric, concentric-eccentric ,eccentric, concentric ,and eccentric-eccentric), isotonic, isometric, and passive protocols should include options for angles, hold-times, rest period, repetitions, and sets. the system should be able to test all the major body segments and joints such as shoulder, forearm, elbow, wrist, hip, knee, and ankle.should have adjustable range of motion stops in full 360 degrees.should have 360-degree rotation for the force arm (connecting dynamometer to the pedal) to have wide range of motionshould be able to accommodate different athletes with varying height and weight with provision for seatbelt harness for better stabilitythe dynamometer or chair should be movable to accommodate different athletes for quick set-up and better usability with locking clamps for securing the system in place for testingshould be able to do gravity correction when the limbs are positioned with the lever arm on the dynamometerthe software should be provided to analyze the raw data and export the raw and processed data in different file formats such as excel, text, etc. the software should provide detailed report for various testing protocols such as individual test for joints, data/graph overlay for comparing pre and post testing, repeatability, progress, multi-session.should be provided with latest compatible workstation/laptop of reputed brand like hp, dell (latest generation) processor, minimum16gb ram, windows os 11, and laser printerconcentric speed: 500 deg/sec or more eccentric speed: 500 deg/sec or more concentric torque: 500 ft-lb (678nm) or more eccentric torque: 500 ft-lb (678 nm) or more isometric torque: 500 ft-lb (678 nm) or more isotonic torque: 500 ft-lb (678 nm) or more isotonic torque as low as .5 ft-lbfeedback formats: roadway, interactive line, interactive path, reaction training, proprioception training, breakout, and pong.torques. time, torques. angle, torque bars, work bars, power bars. it should be possible to use mechanical stops even with custom patterns (important for safety in research)the same attachment should be usable for left and right side of subject for consistencies in data.should be certified and approved by ce/eu medical devices directives or usfda, nord boardit should be portable and should have 2 load cell sensors per unit with easy to attach hooks pivoting 360 degrees joint improving sensor accuracy it should have knee position indicator for replication of test position in each time. should have sample rate per sensor: upto 400hz, capacity per sensor: 100 kg/980-1000n safe over load per sensor: 150kg/1500n, max over load per sensor: 200kg/ 2000n, resolution: 1n and sensitivity: 22.0+/-mv/v. should have rechargeable battery & battery life should be100 active hours approx. should have working temperature range 5-40 c. (all weather proof) latest upgradable software should have both wired & wireless connectivity connec
Tender For supply of single probe receiver assembly complete with tapered bell mouth housing release lever release lever lanyard and indicator arm , base plate for single probe receiver assembly , swivel arm assembly with slip pelican hook arm and bail and jackstay terminal fitting , hinged cover plate for probe receiver , adaptor hose to probe receiver complete with split camp , receiver hose assembly seven inches 177 mm x 4.5 m complete with reusable coupling at one end matching with receiver and the other end with female coupling matching with flange adaptor , flanged adaptor for re usable coupling flange adaptor should be suitable for 7in hose assembly with coupling at one end and din standard flange for 6in deck elbow at the other end , eye plate for in haul line for probe fuelling pl 13 tonnes , snatch block with shackle open type , eye plate for lead block pl 19.5 t , snatch block cw shackle pl 8 t 3 nos to be used on either port or stbd side at one time , 7 in split clamps , c spanner for 7in reusable coupling , c spanner for 7in adaptor , nato 3 avcat reception coupling incl cap and flange suitable for , nato 5 fresh water reception coupling and cap , aluminium fuel filter