Get complete information related to latest Mccb Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mccb Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mccb Tenders.
Tender For supplying electrical materials and repair maintenance services at. grampanchayat chimbali. - electrical material, supplying and erecting modular type switch6a / 10a ., supplying and erecting street light bracket for erection ofsingle fitting made from 40 mm. dia b class g.i. pipe 1.0 m in length along with pole cap of 300 mm length 100 mm dia duly welded ., providing cement concrete foundation including excavationfor the poles 60 cm x 60 cm x 1.5 m deep in 1:3:6 cement concrete (20 x 25 mm stone metal) and 45 cm x 45 cm x 45 cm/45 cm dia. x 45 cm height plinth duly plastered and with necessary curing and finishing in an approved manner.(for 8.5 to 9 m poles), supplying and erecting steel tubular swaged pole 139.7 x 114.3 x 88.9 mm. dia with 4.5x3.65x3.25 mm thickness (4.5 + 1.75 + 1.75m) length respectively and total 8 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, base plate in provided foundation., supplying and erecting steel tubular swaged pole 165.1 x 139.7 x 114.3 mm dia. with 4.5 x4.5 x3.65 mm thickness (5.60 + 2.7 + 2.7 m) length total 11 m long with pole cap, base plate in provided foundation ., supplying and erecting street light bracket made from 25mm. dia b class g.i. pipe, 0.6m. in lengthalong with polecap of 300 mm length and 80 mm dia duly welded with provided leads as per specification, supplying,tpmcb 40a to 63a in provided distribution board, providing pair of duly tested rubber hand gloves as per is:4770 suitable for working upto 22kv supply., supplying and erecting insulated d.p. switch surface type/flush type 32a 240vwith indicator lamp & fuse, supplying h.c. pattern porcelain fuse bridge swith base & hc type fuse links240v 32a, supplying and erecting programmable digital almanactimer microcontroller based with real time clock to operate on derived switching on & switching off street light as per daily sunset and sunrise respectively, 1.25 mm crca sheet metal enclosures with 20a., supplying pvc insulated pvc round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper industrial cable ., supplying and erecting led street light fitting suitable for 60w lamp, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink ., supplying and erectingled street light fitting suitable for 26w to 36w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erectingled street light fitting suitable for 90 w led street light, including lamp, with pf > 0.95 class ip 65 and above housing of pressure die cast alluminium alloy and heat sink., supplying and erecting led flood light fitting of 120w, including lamp, with pf > 0.95,class ip 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium ., supplying & laying pvc armoured cable 4core 6sq mm, supplying & laying pvc armoured cable 4core 10 sq mm, supplying & laying pvc armoured cable 2core 10 sq mm, supplying & laying pvc armoured cable 4core 16 sq mm, supplying, erecting & marking spmcb 6a to 32a, b- series (for lighting), supplying, erecting & marking dpmcb 6 a to 32 a bseries (for lighting), supplying, erecting & marking tpmcb 6 a to 32amp ., supplying, erecting & marking fpmcb 40a to 63a ., supplying & erecting crimping type aluminium lugs for cable upto 16 sq mm., supplying & erecting crimping type coper lugs for cable upto 1.5 to 6sq mm., supplying and erecting two pole power contactor 250v 32a for time switch complete erected on wooden block/provided box, with necessary materials., supplying & erecting mains with2x1.5 sq.mm f.r copperpvc insulated wire laid in provided conduit/trunking/inside pole 1-3-3, supplying and e
Tender For nit 21 work of replacement of submersible pump sets and accessories of tubewell at various locations under uwss chomu under jen section chomu (urban) under sub div chomu in jurisdiction of executive engineer, phed district division ii, jaipur - 2.15 supply & installation of 3 phase isi marked submersible motor pump set of three star or better rating of bee and as per is: 8034-2018 (pump) and is 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/dcb. the job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.2.15.2 up to 5.5 kw (7.5 hp) & head above 120 mtr., 2.15 supply & installation of 3 phase isi marked submersible motor pump set of three star or better rating of bee and as per is: 8034-2018 (pump) and is 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/dcb. the job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.2.15.4 7.5 kw (10 hp) & head above 120 mtr., 2.15 supply & installation of 3 phase isi marked submersible motor pump set of three star or better rating of bee and as per is: 8034-2018 (pump) and is 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/dcb. the job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.2.15.6 9.3 kw (12.5 hp) & head above 120 mtr., 2.18 supply and fixing of electric control feeder panel comprising of suitable rating mccb , fully automatic star-delta starter, over load relay, ampere meter with cts, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. the panel should have space for energy meter ( supplied by discom). all these equipments shall be housed by panel box made out from 18 gauge m.s. sheet with powder coating. panel should be of minimum size 900 x 600 x 450 mm with stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg s length 18 and double door including in built locking system. the legs should be embedded in m-15 cement concrete plat form. the size of cc platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. the panel should have opening of suitable size in front of space for energy meter with glass for meter reading. the operation of panel should be suitable for on 440 volt ac supply.2.18.1 above 5 hp and up to 10 hp, 2.18 supply and fixing of electric control feeder panel comprising of suitable rating mccb , fully automatic star-delta starter, over load relay, ampere meter with cts, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. the panel should have space for energy meter ( supplied by discom). all these equipments shall be housed by panel box made out from 18 gauge m.s. sheet with powder coating. panel should be of minimum size 900 x 600 x 450 mm with stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg s length 18 and double door including in built locking system. the legs should be embedded in m-15 cement concrete plat form. t
Tender For corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For corrigendum : supply erection testing and commissioning of 05 nos. mccb switch disconnectors cubicle and aluminium bus bar along with dismantling of existing old 0.4kv switch disconnectors at various places of matatila power station.
Tender For supply of xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , moulded case circuit breakers (mccb) conforming to is/iec 60947 (part 2) (q2) , electrical cable lugs (q3)
Tender For corrigendum : supply of 26vsmc001boq - rice boiler 80 ltr./380v , s.s.304 , motor 4 kw 415-3-50 (1604) , combi steamer oes 6.06 , 230v , cocinas , ebb 2000 , motor fan , bohnhoff bob-3 , thermocouple control , chapatti 500 , main switch , sk group , idly 2000/hr , proximity sensor , m.c.b. 100a- 4-pole , heating element cooking range , combisteamer-scc101e , timer 0-60min , 1 hp ac motor bharat bijlee , bohnhoff , easy 200 , heating element set , mccb 100a , 3 pole , bohnhoff , easy 150 , water tap 1/2 , fusible link , 360 deg.f (sl style) , bohnhoff , nn-gd 371s , door switch , 2kw embedded hot plate with element , heating element