Get complete information related to latest Mccb Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mccb Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mccb Tenders.
Tender For nit 21 work of replacement of submersible pump sets and accessories of tubewell at various locations under uwss chomu under jen section chomu (urban) under sub div chomu in jurisdiction of executive engineer, phed district division ii, jaipur - 2.15 supply & installation of 3 phase isi marked submersible motor pump set of three star or better rating of bee and as per is: 8034-2018 (pump) and is 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/dcb. the job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.2.15.2 up to 5.5 kw (7.5 hp) & head above 120 mtr., 2.15 supply & installation of 3 phase isi marked submersible motor pump set of three star or better rating of bee and as per is: 8034-2018 (pump) and is 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/dcb. the job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.2.15.4 7.5 kw (10 hp) & head above 120 mtr., 2.15 supply & installation of 3 phase isi marked submersible motor pump set of three star or better rating of bee and as per is: 8034-2018 (pump) and is 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/dcb. the job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect.2.15.6 9.3 kw (12.5 hp) & head above 120 mtr., 2.18 supply and fixing of electric control feeder panel comprising of suitable rating mccb , fully automatic star-delta starter, over load relay, ampere meter with cts, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. the panel should have space for energy meter ( supplied by discom). all these equipments shall be housed by panel box made out from 18 gauge m.s. sheet with powder coating. panel should be of minimum size 900 x 600 x 450 mm with stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg s length 18 and double door including in built locking system. the legs should be embedded in m-15 cement concrete plat form. the size of cc platform should be equal or bigger than the base size of panel having height of at least 200 mm from ground level. the panel should have opening of suitable size in front of space for energy meter with glass for meter reading. the operation of panel should be suitable for on 440 volt ac supply.2.18.1 above 5 hp and up to 10 hp, 2.18 supply and fixing of electric control feeder panel comprising of suitable rating mccb , fully automatic star-delta starter, over load relay, ampere meter with cts, volt meter, phase preventer, suitable starting capacitors, phase indicators, lighting arrangement etc complete suitable for three phase pump set. the panel should have space for energy meter ( supplied by discom). all these equipments shall be housed by panel box made out from 18 gauge m.s. sheet with powder coating. panel should be of minimum size 900 x 600 x 450 mm with stand ( made of angle iron of size 35x35x5mm) duly bolted/screwed with enclosure box having 4 legs, each leg s length 18 and double door including in built locking system. the legs should be embedded in m-15 cement concrete plat form. t
Tender For corrigendum : supply of 420kv 3ph spring operated sf6 gas circuit breakers -supply of 420 kv 3150a 63 ka 3ph sf6 gas circuit breaker without pir and without csd , supply of 420 kv 3150a63 ka 3ph sf6 gas circuit breaker with pir and without csd , mandatory spares for cb of 420kv 3150a 63 ka 3ph sf6 gas circuit breaker without pir , mandatory spares for cb of 420 kv 3150a 63 ka 3ph sf6 gas circuit breaker with pir , retrofitment charges of existing bhel make hydralic type cbs withand without pirs with new 420kv 3150a 63ka 3ph sf6 gas so cb
Tender For corrigendum : supply of service 11 kv ht panel as per sepcifications , sf new mineral oil for panel etc as per sepcifications , calibration relay etc as per sepcifications , replacement digital ammeter for ht panel , replacement digital voltmeter for ht panel , replacment ryb ind lamp led type in ht panel , sf 2a hrc fuselink in ht panel , servicing 1500kva dry type transformer as per sepcifications , servicing 2 runs 2500a tpn bustrunking as per sepcifications , service mv lt panel with 2500a 4p acb 3 nos as per specifications , service mvlt panel with mccb incoming as per specifications , checking and repair of em intelocking , dismentaling 3.5 sq mm 240 or 300 sq mm al cable as required , pf adaptor box aprx 1.5 ft x 1.5 ft x 1.5ft of 16swg ms sheet as reqd , pvdg panel module door key as reqd , pvd and fixing operating handle for 250a 4p changeover as reqd , replacement 160a hrc fuse with base in extg cap panel , replacement 3p 50kvar cap duty contactor in extg cap panel , replacement 25sq mm cu lead wire 1ft length in extg cap panel , checking etxg 2no 25kvar cap bank and fault repair reinstallation , dismentaling uv protection connections as reqd , replacement digital ammeter for lt panel , replacement digital voltmeter for lt panel , replacment selector switch in lt panel , replacment ryb ind lamp led type in lt panel , sf 2a hrc fuselink in lt panel , sf 32a hrc fuseling incl removing faulty item from lt panel as reqd , sf 63a hrc fuseling incl removing faulty item from lt panel as reqd , sf 100a or125a hrc fuseling incl removing faulty item from lt panel as reqd , sf 250a hrc fuseling incl removing faulty item from lt panel as reqd , sf new 5 or 6 amp piano switch in replacement of faulty item , sf new 5 or 6 amp 3pin socket outlet in replacement of faulty item , sf new 15 or 16 amp piano switch in replacement of faulty item , sf new 15 or 16 amp 6pin socket outlet in replacement of faulty item , rewinding ceiling fan motor , sf 4ft 20w led fitting against faulty fitting , service of 750kva dg set as per specification , service dgset control panel 1250a 4p acb as per specification , repacement ryb ind lamp in dg set panel , repacement digital ammeter in dg set panel , earthing testing in existing earth pits and report submission
Tender For corrigendum : supply erection testing and commissioning of 05 nos. mccb switch disconnectors cubicle and aluminium bus bar along with dismantling of existing old 0.4kv switch disconnectors at various places of matatila power station.
Tender For supply of xlpe cable for working voltage up to and including 1.1 kv marked to is 7098 (part 1) (q2) , moulded case circuit breakers (mccb) conforming to is/iec 60947 (part 2) (q2) , electrical cable lugs (q3)
Tender For corrigendum : supply of 26vsmc001boq - rice boiler 80 ltr./380v , s.s.304 , motor 4 kw 415-3-50 (1604) , combi steamer oes 6.06 , 230v , cocinas , ebb 2000 , motor fan , bohnhoff bob-3 , thermocouple control , chapatti 500 , main switch , sk group , idly 2000/hr , proximity sensor , m.c.b. 100a- 4-pole , heating element cooking range , combisteamer-scc101e , timer 0-60min , 1 hp ac motor bharat bijlee , bohnhoff , easy 200 , heating element set , mccb 100a , 3 pole , bohnhoff , easy 150 , water tap 1/2 , fusible link , 360 deg.f (sl style) , bohnhoff , nn-gd 371s , door switch , 2kw embedded hot plate with element , heating element