Web Analytics Made Easy - StatCounter

Mechanical Paver Tenders

Get complete information related to latest Mechanical Paver Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Mechanical Paver Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Mechanical Paver Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :45720703 Due date: 30 Jul, 202630 Jul, 2026 2.00 Crore
Tender For inviting rates of different items for construction of diffrent type of work as per demand on cm help line or ward parsad or public - supply of handpump material 2026-27, excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location with all lifts and lead up to 1000 m as per section-300 of the specifications.item no nvi-3.12, construction of embankment/sub-grade/earthen shoulders with material obtained from other sources, as per provisions of section 305 of the specifications, with approved materials/soil confirming to requirements given in table 301-1 of specifications including all lead and lifts, including cost of watering, compaction by vibratory roller/heavy pneumatic type roller etc. confirming to requirements given in table 301 2 of the specifications complete.item no nvi-3.12, construction of granular sub-base, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method at omc and compacting with vibratory roller of 80-100 kn static weight to achieve the desired density, including all lifts and lead complete in all respect as per section-400 of the specifications.by mix in place method item no nvi -4.1.1.1, construction of dry lean cement concrete sub- base over a prepared sub-grade with coarse and fine aggregate conforming to is: 383, the size of coarse aggregate not exceeding 26.5mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1 of the specifications, cement content not to be less than 150 kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 mpa at 7 days, mixed in a batching plant, transported to site, laid with paver with electronic sensor/mechanical paver, compacting with 8-10 tonnes vibratory roller, finishing and curing and as per section 601 of specifications.item no nvi- 6.1.1, providing and laying cement concrete grade m-20 with 20 mm graded crushed stone aggregate, mixing shall be in mechanical mixer, laying with paver compacting by use of pin, plate / screed vibrators including form work by strong steel girders fixed by spikes, separation membrane 125 micron thick, including cutting of joints @ 4 to 5 m interval and filling it with hot applied bituminous sealant (without dowel bars) (max. thickness 20 cm).item no nvi-6.4, construction of dowel jointed, plain cement concrete pavement in m-30 grade concrete over a prepared sub base with 43 or higher grade cement, coarse and fine aggregate conforming to is:383 maximum size of coarse aggregate not exceeding 25 mm, mixed in a batching and mixing plant as per approved mix design, transported to site, laid with a fixed form or slip form paver with electronic sensor spreading the concrete by shovels, rakes compacted using needle, screed and plate vibrator and finished in a continuous operation including provision of contraction, expansion, and longitudinal joints, joint filler, separation membrane, sealant primer, joint sealant, debonding strip, placing of dowel bar, tie rod admixtures as approved, curing compound, finishing to lines and grades as per approved drawings as per irc:15 and as per section-602 of the specifications complete excluding cost of steel in dowel bar and tie rod etc.item no nvi-6.2.1, earth work in excavation for foundation, trenches for pipes / cables or drains etc. by mechanical means / manual means (exceeding 30cm in depth.) including ramming of bottom,dressing of sides,disposal of excavated earth including of all lift and lead upto 50m.disposed earth to be levelled and neatly dressed.all kinds of soil item no nii 2.6.1, demolishing cement concrete manually/by mechanical means including disposal of material with in 50 meters lead as per direction of engineer-in-charge.1:3:6 or richer mixitem no nii

Central Government/Public Sector

CTN :45365796 Due date: 04 Jul, 202604 Jul, 2026 11.50 Lacs
Tender For corrigendum : repair resurfacing of certain roads and connected items at bd bari mil stn - m&l preparing black top surfaces by brushing with wire brushes for removing caked mud etc. sweeping with wire brush/brooms and finally fanning the cleaned surface with gunny bags or by mechanical blower to remove all loose dirt etc to black top surfaces, and applying evenly a priming/tack (viscosity grade paving bitumen of grade vg-10) @ 5 kg per 10 sqm to road surface bituminous asphaltic semi dense concrete consolidated thickness 30 mm with stone chippings graded aggregate with 5.5% of binder content by weight of total mix, (viscosity grade paving bitumen of grade vg-30) and 4% stone dust conforming to required specification for filler as per irc-95, 1987 (filler) by weight of mix, prepared in hot mix plant, rolled and compacted to required camber and gradient to uniform smooth surfaces by mechanical paver and rolled with 8 to 10 tone power roller completed all as specified and as directed., m&l for repair to potholes, any depth ,not exceeding 1 sqm each including sweeping free from dust and mud or water, scoring sunken surfaces in roads, path etc, cutting around edges to at least 25mm in depth, making good by filling in screened and graded road metal, watering and well ramming, applying tack coat with (viscosity grade paving bitumen of grade vg-10) @ 10.0 kg per 10 sqm of surface putting in & including premixed bituminous macadam, well rammed and sealed with binder 9.80 kg/sqm, blinded with 0.09 cum of stone chippings, 6.3mm size and again well rammed, rolled and compacted to required camber and gradient to uniform smooth surfaces by mechanical paver and using with 8 to 12 tonne power roller (including supply of premixed macadam, binder and chippings),completed all as specified and as directed., premix bituminous macadam laid / rolled and compacted using 8 to 12 tonne power roller to required gradient and camber, with broken stone graded aggregate with 4% of paving bitumen binder of viscosity grade vg-30 grade by weight of toal mix (consolidated thickness 75mm or less) completed all as specified and as directed., m&l providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required completed all as specified and as directed., m&l for marking lines 2.5 mm thick, dashes arrows etc of any description n. exc 10cm width/girth on road surface using hot applied thermo plastic road marking paint of approved colour confirming to bs-3262-1989 with special applicator machine all as per manufacturere instruction completed all as specified and as directed., supply and fix solar cat eye (green/red) aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency mono rystafie solar panel 2.4v/ 0.3 watt one ni-ed rechargeable battery (1.2v/ 1600ma) consisting of super bright led with 10,000 to 18,000 mcd completed as per manufactures instructions etc completed all as specified and as directed., supply and fixing metal tubular dealineator made out of abs round body fitted with 2 nos 65 mm dia highly reflective reflectors made out of and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in pcc 1:2:4 (150x150x300mm) type b1 complete all as specified and directed, s&f manufacturing, supplying and fixing retro reflective mandatory/ regulatory sign boards of 900 mm diametre with support length of 3750 mm and made up of 2 mm thick aluminium sheet, face to be fu

CTN :45695472 Due date: 30 Jun, 202630 Jun, 2026 4.92 Lacs
Tender For -- work of purchasing lighting equipment to repair damaged road lights in the municipal area.

State Government

CTN :45611569 Due date: 25 Jun, 202625 Jun, 2026 75.14 Lacs
Tender For development of park and installation of outdoor gym and outdoor children play equipment at 17 and 45 47 rajpur road and repair of pathway replacement of old broken tiles on the staircase repair old damaged outer boundary wall repairing of shed cons

CTN :45565907 Due date: 23 Jun, 202623 Jun, 2026 NA
Tender For supplying of materials and supplying and spreading of materials at various places of vapi municipal area. annual rate 2026-2027 - supplying of yellow earth, garden soil at site as directed., supplying of hard murram at site as directed., supplying of coarse clean sharp sand at site as directed., supplying of crushed stone aggregates, chippings etc. of disintegrated pieces, eletatrious and organic matter (for bitumen surface dressing etc.) and grading as per i.r.c.code., (i)10 mm to 40 mm size m/c metal, (ii)6 mm to 10 mm size grit., (iii) 40 mm to 90 mm size metal, (iv)9 thick rubble, supplying bricks., supplying of granular sub base by providing coarse graded material, mixing by mix in place method with rotavator at omc, with grading material of 53 mm to 26.5 mm size @35 percent,26.5mm to 4.75 mm @ 45 percent and 2.36mm below @ 20 percent at site as directed., providing wet mix base course maximum 200 mm thick using machine crushed b.t. chips as per required gradation mixing with required optimum quantity of water conveying the mix to site of work, including cost of materials labour plant and equipment etc complete, construction of granular sub-base by providing coarse graded material(metal), spreading in uniform layer on prepared surface mixing by mix in place method with rotavator at omc, and compacting with vibratory roller to achieve the desired density, etc, complete as directed by engineer in charge., providing and laying wet mix base course maximum 150 mm thick using machine crushed b.t. chips as per required gradation mixing with required optimum quantity of water conveying the mix to site of work, spreading into grade and camber with mechanical paver and consolidation with vibratory road roller including cost of material labour plant and equipment etc complete as directed by engineer in charge., supplying and spreading of following materials at site as directed by engineer in charge including rolling and consolidation with vibratory roller as directed by enigineer in charge., (i)10 mm to 40 mm size m/c metal, (ii)6 mm to 10 mm size grit., (iii)40 mm to 90 mm size metal, (iv)9 thick rubble, supplying and spreading hard murram including rolling and consolidation with vibratory roller as directed by enigineer in charge., note:- all rate are required compulsory

CTN :45408720 Due date: 09 Jun, 202609 Jun, 2026 5.65 Lacs
Tender For corrigendum : maintenance of electrical installation & fans, repair maintenance of pump sets, sub-station equipment, dg sets at 25 akbar road, new delhi. (sh: miscellaneous repair work and renovation of room no. 59 and 60.)subwork/packages:maintenance of electrical installation of fans, repair maintenance of pump sets, sub-station equipment, dg sets at 25 akbar road, new delhi. (sh: miscellaneous repair work and renovation of room no. 59 and 60.)

corporations/Associations/Others

CTN :45397409 Due date: 12 Jun, 202612 Jun, 2026 3.89 Lacs
Tender For now repair and maintenance of infrastructure assets in cp division during 2026-27. sh replacement of old damaged gym equipment at cpwd complex hanuman road connaught place.

CTN :45138827 Due date: 01 Jun, 202601 Jun, 2026 NA
Tender For bid to ras supply of s and f of ring main system for wss - supplying laying jointing commissioning and testing 100mm bore centrifugally cast spun ductile iron pressure pipe with spigot and socketed ends class k7 confirming to is 8329 or 2000 as per atc , supplying laying jointing commissioning and testing 150mm bore centrifugally cast spun ductile iron pressure pipe with spigot and socketed ends class k7 confirming to is 8329 or 2000 as per atc , supply and fix valve reflux with by pass arrangement 100mm 4 inches dia , supply and fix foot valve confirming to is 4038 100mm 4 inches dia , supply and fix valve sluice flanged of class 1 point 6pn 100mm 4 inches dia , supply and fix valves sluice flanged of class 1 point 6 pn 150mm 6 inches dia , supplying installing testing and comissioning of centrifugal pump electric driven capacity not less than 25 lps discharge at 60 metre head in load as per atc , supply laying testing cable xlpe insulated screened pvc bedded galvanized steel strip wire armd electric powercable hd 1100v grade stranded aluminium conductor size 70 sqmm 3 point 5 core , supply laying testing cable xlpe insulated screened pvc bedded galvanized steel strip wire armd electric powercable heavyduty 1100v grade stranded aluminium conductor size 10 sqmm 4 core , supplying installing testing and commissioning of outdoor type factory made crca sheet thickness 3 point 15mm platform mounted lt panel board to accommodate as per atc , supplying installing testing and commissioning of indoor type factory made crca sheet thickness 2mm platform mounted lt panel board to accommodate as per atc , supply install test commission centrifugal openwell submersible pump cap 10hp singlephase discharge range 740 to 200lpm head range 35 to 54m suction x discharge pipe dia 65x50mm as per atc , supply and fix cast iron air valves with two air outlets 80mm dia bore and fixing up in ) /bid number : gem/2026/b/7514655 * /dated: 08-05-2026 & & / bid document 1 / 21 & & ' ' /item category cast iron water supply mains , excavation in tranches not exc 1 point 5m wide n exc 1 point 5m depth over exc 10sqm on plan and n exc 1 point 5m in depth for foundations shafts wells cesspite mainholes pier holes as per atc , returning filling in including spreading laveling watering and well ramming in layers n exc 25cm in soft or loose soil complete all as specified and directed by engr in charge , removal of excavated soil material to a distance not exc 50m or depositing where directed at a level not exc 1 point 50 metre above th staring point complete all as specified as per atc , boring of hole under road pavement hardstanding by trenchless technology using ultra sounding technique nec machine incl hdpe pipe 150mm dia suitable for 0 point 4mpa working pressure , cutting existing ci or di pipe line of 150mm and inserting tee of size 150 x 150 x 150mm for taping complete all as specified and directed note tee 150 x 150 x 150mm paid separetly in di special , cutting existing ci or di pipe line of 150mm and inserting tee of size 150 x 150 x 100mm for taping complete all as specified and directed note tee 150 x 150 x 100mm paid separetly in di special , di or ci special such as tee bend collar tail piece and other fitting as required , earthing of poles and other machinery or equipment using 4mm gi wire as earthing lead and ms galvanized plate of size 60cm x 60cm x 6mm as earth electrode , demolition and diasmanttling of concrete in ground floor and pavings n exc 15cm thickness , m and l of cement concrete b 2 1 colon 2 colon 4 40mm graded aggregate 100mm thickness , m and l for contruction of brick masonry valve pit in repair of inter size 90x90x90cm incl nec exc earth work in soft or loose soil brick work plastering white wash pcc coping ms frame as per atc , m and l for contruction of brick masonry valve pit in repair of inter size 120x120x90cm incl nec exc earth work in soft or loose soil brick work plastering white wash pcc coping ms frame

Central Government/Public Sector

CTN :45137990 Due date: 27 May, 202627 May, 2026 NA
Tender For corrigendum : repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; tender for the job of obtaining consent to establish for hter scheme at rcf thal unit through nipl route; as per scope of work; a) safety violation by contractor employee at work place: 1) working without wearing safety helmet (per person), 2) working without wearing safety shoes (per person), 3) working without wearing safety goggle &/or hand gloves during handling of hazardous chemicals, acid/alkali etc. (per person), 4) working without wearing safety belt (double lanyard full body harness) for height jobs above 2 meters. (per person), 5) working without wearing face shield during cutting, welding, grinding activity and during maintenance work on process lines and equipment. (per person), 6) not using ppe, tools/tackles as mentioned in safety work permit (per person), 7) working without valid test certificate for lifting tools/tackles (per incidence observation), 8) working without appropriate electric plug-pin, elcb/rccb/rcbo (per incidence observation), 9) working without a valid safety work permit (per incidence/ observation), 10) permit not available at site (per incidence/observation), 11) gas cylinder without flash back arrestor (per incidence observation), 12) gas cutting set with damaged hose pressure gauge without valve key (per incidence/observation), 13) gas cylinder without trolley (filled and empty) (per incidence/ observation), 14) unauthorized personal entering into cordon off area (per incidence/observation), 15) faulty wire/cable laying on ground or using snapped cables (per incidence/observation)., 16) improper hand tool or power tools (per incidence observation), 17) smoking at work place area. (per person), 18) found in intoxicated state (per person), 19) violation of road rules (per incidence observation), 20) b) safety violations by transport contractors, 21) faulty hazchem displayed on tanker (per incidence observation), 22) one pvc/tychem suit set if available (per incidence/ observation), 23) both pvc/tychem suit set are not available (per incidence observation), 24) fire extinguisher without hydro test. (per incidence/ observation), 25) trem card not available (per incidence/observation), 26) hazardous chemicals transportation training of driver by authorized agencies. (training card not available with driver) (per person), 27) lying/resting below the vehicle(per incidence/observation), 28) any other deviation found as per checklist for tankers (per incidence/ observation.

State Government

CTN :45205551 Due date: 21 May, 202621 May, 2026 9.64 Lacs
Tender For 1) maintenance of electrical installation , fans and repair maintenance of pump sets, ac equipment, diesel generator set installed at cpo building, kahmere gate, delhi. 2) maintenance of electrical installation , fans and repair maintenance of pump sets, ac equipment installed at sub-registrar office , asaf ali road, kashmere gate, delhi. 3) maintenance of electrical installation , fans, compound li
 Loading, Please wait...

Connect us via What's Up