Get complete information related to latest Ms Channel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ms Channel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ms Channel Tenders.
Tender For repair/ maint of lt ug cables and its connected items of masimpur mil stn incl army est at khumbigram under masimpur mil stn - e & m division items, dismantling of old unserviceable/damaged acsr or aac conductors of any size , jumper from overhead line & stacking serviceable & non serviceable material separately complete all as specified and directed., dismantling of old unserviceable/damaged stay assembly embedded in concrete including demolition of pcc and removing unserviceable meterials from site of work complete all as specified and directed., dismantling of cross-arms of mschannel or angle of any sections complete all as specified and directed., dismantling of insulators of any size/type complete all as specified and directed., dismantling earth wire or copper conductor/ cradles/stay /service feeder or distribution span complete all as specified and directed, excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for laying of cable/poles and getting out in soft/loose soil complete all as specified and directed., returning, filling in trenches with soil obtained from excavation including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed., removing excavated materials to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all all as specified and as directed., supply and laying burnt bricks of sub-class b of size 230mm x 115mm x 75mm laid in trenches for cable protection complete all as specified and as directed, supply and spread dry fine sand in trenches as sand cushioning to under ground cable for protection with fine river sand and provide reqd cover after punning down complete all as specified and directed. note: thickness of sand cushioning after punning down will be measured and paid separately., m&l for cutting existing road / pcc drain for taking out / laying of underground cable and including necessary earth work and making good to match with the existing surface with pcc 1:3:6 type ci using 20mm graded aggregates complete all as specified, taking down or out existing cable of sizes 10 sqmm to 70 sqmm 2/3.5/4 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, taking down or out existing cable of sizes 95 sqmm to 300 sqmm 3.5 core with cable cover, jointing kit from the trenches / ducts/ along walls / poles / through poles / under roads/ inside sub station including segregation the serviceable cable by cutting down defective portion after testing by meggar (insulation tester ) , stacking and rolling unserviceable cable for further disposal all as directed by engineer in charge. note :-(1) excavation / cutting of road or floor/ gi pipe & laying / relaying of cable etc shall be measured and paid seperately under respective item of this schedule, relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 10 to 70 sqmm 2/3.5/4 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc complete all as directed and specified. note :- lugs and glands will be measured and paid separately., relaying only serviceable cable obtained from taking out in same or new location or through cable ducts inside sub station of size 95 to 300 sqmm 3.5 core in trenches / ducts / along walls / poles / under road etc including necessary cable lugs, glands etc compl
Tender For special repairs to lt panels and connected items at pyro, pinaka, nag mixture building, magazine area and ap building in hemrl, pune - taking out old serviceable/unserviceable lt panel/capacitor panel of any description or capacity keeping aside in safe custody for schedule of credit complete all as specified and directed, supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, mschannels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 03 nos, (c) mccb 4p, 125 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 200/5 - 04 nos, (e) control mcb c curve, sp, 6 to 32a, 10ka, c curve - 02 nos, (f) led phase indicator (r,y & b) - 01 set. (pyro sub stn), supply, fixing and commissioning of cpri approved factory made lt cubicle panel board outdoor type conforming to is/iec-61439-1&2 : 2011 with canopy, louvers & shutters made out of 3.15 mm thick crca sheet totally enclosed with necessary ventilations, weather, dust and vermin proof with front and rear opeing and lcoking arrangement, degree of protection ip 56, 415 volts, 3 phase, 4 wire, 50 hz having aluminium bus bar of capacity 1200 amps tpn duly colour coded and for neutral supported with dmc/smc insulator colour coded with heat shrinkable sleeve having short circuit current with minimum 65 ka for one second and suitable for internal connection including instantaneous over load and earth fault relays complete with digial type voltmeter and ammeter inclduing suitable range of cts of metering, selector switches for voltmeter and ammeter, set of three led type indicating lamps duly wired with suitable size of copper cables and panel board shall be grouted in the ground with suitable size of foundation in pcc 1:2:4 type b1, mschannels 50 x50 x 6mm with nut bolts, wahsers, etc. suitable for fixing with bus duct including comprising of the following:-incoming: (a) acb adjustable type with thermal magnetic release 4 pole, 800a, 415v, 50 ka, 50 hz - 01 no. outgoing: (b) mccb 4p, 400 amps, 36 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (c) mccb 4p, 315 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 01 nos, (d) mccb 4p, 250 amps, 25 ka,415v, ac supply including extended rotary handle and spreader terminals fo incoming and outgoing - 02 nos (e) panel mounted type digital multifunctional energy meter a, v,z, kw, pf t operated, lt 3 phase, 4 wire inclding ct ratio 800/5 - 04 nos, (e) con
Tender For supply of casing assy lh head light part no 255b8403181b, catch hood top complete part no 2148402680, chain pawl split pin comp towing hook a part no 255b2707222, channel run side door window drop glass part no 2146103268, connector 3 terminal part no psi3723000a2, cover battery container part no 255b3703170b, cover gear lever 3 type part no nk, door inner handle part no niv-3253, door lock lh & rh part no dmd-niv-3254, door outer handle part no niv, door rear weather strip part no 2146107042b1, door window drop glass gasket part no 2146103218, elastic resilient part no 255b2806030, emblem manufacture part no 2148401300b1, flange door outer handle part no 212a6105160, fuel level indicator transmitter switch part no 2143806014p19a2, handle regulator part no nk, hose assy part no 214b3506135, lever assy back rest part no 25686804088, link slotted wind shield part no 2145204012, lock part no 25686804103, lock part no 25686804104, mirror part no 2568201012
Tender For set of safety bracket assembly of bp and fp end cocks for wag 9/wap-7 locomotives consisting of two items-- (i) ms plate for bracket assembly of bp and fp end cocks for wag-9/wap-7 loco s as per s.c. rly. drg. no.- c/els/lgd/ex.ftg/4/25 material: ms as per ls: 2062. note: thickness of the plate is 20mm instead of 16mm. qty.= 01 no. & (ii) mschannel of size 150 x 75 x 6 (430 mm long) al ong with ms plate of size 150 x 75 x 16 mm i.e. ms plate (ref: 2) to be welded to the channel (ref:1) a t one end as per s. c. railway drg. no.- c/els/lgd/ex.ftg/3/12 (alt.-1), reference no.- 1 & 2 qty.= 02 nos. (1 set= 2 items in 3 nos.) (04 set of sample to be got approved before bulk supply of material). [ warranty period: 30 months after the date of delivery ] ]
Tender For bid to ras bid to ras supply of channel mild steel 250x82x9x14 1 mm , un equal alu alloy angle bar 150x100x10mm l 4000mm , steel channels 3 x 1-1 2 x 1-1 2 x 3 16 , channelms 150x75x5 4 x 9 mm , steel angle equal mild 100mm x 100mm 8 mm , alu alloy angle bar 50x 50x 5mm l 5000mm , alu alloy angle bar 75 x 75 x 10mm l 4000mm or above , ms angle 90mm x 90mm x 10mm , angles equal ms 55x 55x 6mm , channel mild steel 175 x 7 5 x 10 2 mm , alu alloy angle bar 100 x 100 x 10mm l 4000mm , alu alloy angle bar 75 x 75 x 6 mm l 4000mm or above , angles equal ms 100 x 100 x 10 mm , mschannel 100 mm x 50 mm x 4 7 mm web x 7 5 mm flan , angles equal ms 65 x 65 x 6 mm
Tender For corrigendum : 1.4 m long m.s. channel bracket with clamp - supply of 1.4 m long m.s. channel bracket with clamp as per tender specifications tn-2155
Tender For supply delivery installation and commissioning of 10 nos of 1.5 tonne capacity 5 star split air conditioner units with accessories to be installed at hostel building in training centre - supply, delivery, installation and commissioning of following materials., supply and fixing of 1.5 tr 5 star split type ac unit, supply and fixing of double booster voltage stabilizer - 4kva, supply and fixing of ms stand for fixing out door unit, supply fabrication and fixing of mschannel for mounting the air conditiong outdoor unit, supply and laying of 5/8" and 3/8" copper pipe (extra beyond 3 meters supplied with ac unit), sub total (excluding gst), gst @18%