Get complete information related to latest Ms Enclosure Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ms Enclosure Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ms Enclosure Tenders.
Tender For purchase of electrical material for student activity centre and department of languages in mdu - aluminum bus bar,250 amp. 4 pole mccb 25 ka with 2 spreader link set, msenclosure 250 amp. mccb, fastner 10 mm nut bolt type, aluminium thimble 120 mmsq, lt outdoor approxi joint kit 185 sqmm 4 core, hardner and compound
Tender For supply of equipment for electrical and electronics engineering department - supply of equipment forelectrical and electronics engineering departmen, loading rheostat 3 phase :specification :rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , loading rheostat 1 phase :specification :type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , single phase resistive load :specification :type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , three phase capacitor bank :specification :3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated msenclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , plc tranier kit:specification :plc make :allen-bradley / delta electronics / siemens orequivalentdigital inputs : 8 20 nos.digital outputs : 6 12 nos. (led / relay type indication)communication port : rs232 / usb / ethernet (if available)programming method : ladder logic programmingtoggle switches for digital input simulationled indicators for output status indicationanalog potentiometers for analog input experimentsproximity sensor interface providedrelay output interface providedinput supply : 230 v ac, 50 hzbuilt-in regulated 24 v dc power supplyladder diagram programming software to be providedcompatible programming software license to be providedsuitable for basic plc programming and automationexperiments
Tender For supply of equipment items - , "acidity test kit-ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications ", "3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated msenclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided ", "linear variable differentialtransformer measurement trainerspecifications: input supply : 230 v ac, 50 hz type : linear variable differential transformer (lvdt) trainer kit lvdt stroke length : 25 mm led display provided digital voltmeter provided for output measurement potentiometer provided for calibration and adjustment signal conditioning circuit inbuilt zero adjustment and calibration facility provided test points provided for waveform/signal observation clearly labeled circuit diagram on front panel proper insulated terminals and safety sockets provided "
Tender For supply of 26mm dia lifting/pickup chain+2 shackles+1 master link of 40mm dia , galvanised , length-2mtr , mbl-55t , item no-15 , for spm , 26mm dia snubbing chain c/w 2 shackles and master link assembly , galvanised , length-11mtr , mbl-55t , item no-13 , for spm , 200 tone mooring haswer shackle of 18 inch jaw , modified ocimf chafe chain a , generally inaccordance with ocimf 2007 , manufactured from76mm nom. dia. grade r4 material in accordance withiacs w22 and consisting of 1 x special end link1 x enlarged link30 x common links1 x 67mm kenter shackle (grade u3) , safe workingload 250 tonnesproof load 482 tonnes , minimum break load 612 tonnes. , ocimf chafe chain c , in accordance with ocimf 1993 , manufactured from 54mm nom. dia. grade u3 material and consisting of 1 x special end link , 1 x enlarged link , 12 x common links , 1 x 60mm common link , 1 x oblong plate1 x 42t pick-up shackle-safe working load 100 tonnes , proof load 162 tonnes , minimum break load 231 tonnes. , hawser timble 18 inch /21 inch stainless steel reusable bellmouth thimble complete with ss roll the roll bored suitable for 18 inch x 200 t swl wide jaw shackle for spm
Tender For purchase of equipments for eee department - 3 phase capacitor bank :* 3-phase capacitor bank * rating: 2 kvar * voltage: 440 v ac * frequency: 50 hz * heavy duty self-healing capacitor units * powder coated msenclosure * compact panel mounted/floor mounted construction * proper ventilation arrangement to be provided * capacitor duty contactor/switch to be provided * fuse/mcb protection to be provided * discharge resistors to be provided for safety * proper earthing arrangement provided, 3 phase auto transformer starter :* 3-phase variable autotransformer * input: 415 v * output: 0 470 v ac (continuous) * current: 15 a * copper wound, carbon brush type * heavy duty toroidal/core construction * mounted in powder coated ms/crca enclosure * front panel mounted voltage control knob with scale indication * proper insulated terminals provided * floor/bench mounted type suitable for laboratory use * input/output terminal arrangement provided * mcb/fuse protection provided * proper earthing terminal provided * ventilation arrangement for heat dissipation, linear variable differential transformer measurement trainer :* input supply : 230 v ac, 50 hz * type : linear variable differential transformer (lvdt) trainer kit * lvdt stroke length : 25 mm * lcd display provided * digital voltmeter provided for output measurement * potentiometer provided for calibration and adjustment * signal conditioning circuit inbuilt * zero adjustment and calibration facility provided * test points provided for waveform/signal observation * clearly labeled circuit diagram on front panel * proper insulated terminals and safety sockets provided, plc trainer kit :* plc make :allen-bradley / delta electronics / siemens or equivalent* digital inputs : 8 20 nos.* digital outputs : 6 12 nos. (led / relay type indication)* communication port : rs232 / usb / ethernet (if available)* programming method : ladder logic programming* toggle switches for digital input simulation* led indicators for output status indication* analog potentiometers for analog input experiments* proximity sensor interface provided* relay output interface provided* input supply : 230 v ac, 50 hz* built-in regulated 24 v dc power supply* ladder diagram programming software to be provided* compatible programming software license to be provided* suitable for basic plc programming and automation experiments, conveyor arrangement with siren :* input supply : 12 v dc / 24 v dc / 230 v ac, 50 hz* control mode : manual / automatic operation using plc* conveyor arrangement with geared dc motor provided* proximity sensor provided for object detection* start and stop push buttons provided* audio siren indication provided* plc based control and sequencing operation provided* mini conveyor setup suitable for laboratory demonstration* geared dc motor driven conveyor mechanism* smooth belt movement with roller arrangement, digital storage oscilloscope (dso) :* bandwidth: 50 - 100 mhz. * sampling rate: 1gs/s. * channels: 2 (minimum) * power supply: 100v 240v ac, 50-60 hz * automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., * horizontal scale: 5 ns/div 50 s/div or equivalent * vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) * waveform math: +, -, x , , invert, fft etc., * waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. * 7-inch color display or equivalent * input impedance - 1 m 2%, // 20 pf 2 passive probes (1x/10x), on/off control of lamp using solid state relay kit:* type : solid state relay (ssr) trainer kit* control/input voltage : 12 v / 24 v dc or up to 30 v dc* output load voltage : 230 v ac, single phase* load control : on/off control of ac lamp load* solid state relay based switching circuit* opto-isolated input control* built-in ac lamp load* manual on/off switching arrangement* led indication for input and output statu
Tender For supply of lab equipments - purchase of lab equipments, acidity test kitspecifications:ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, single phase resistive loadspecifications:type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability, three phase resistive load specifications:rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided, three phase capacitor bank specifications: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated msenclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided, 3 phase auto transformer starter specifications: 3-phase variable autotransformer input: 415 v output: 0 470 v ac (continuous) current: 15 a copper wound, carbon brush type heavy duty toroidal/core construction mounted in powder coated ms/crca enclosure front panel mounted voltage control knob with scale indication proper insulated terminals provided floor/bench mounted type suitable for laboratory use input / output terminal arrangement provided mcb/fuse protection provided proper earthing terminal provided ventilation arrangement for heat dissipation, 3 floor lift interfacing model specifications: type: table-top lift model floors: 3 levels structure: transparent acrylic / ms frame cabin: moving lift car with guide rails drive: dc geared motor / stepper motor motion: up/down movement, floor indication leds (1, 2, 3) direction indicators (up/down), start & stop atevery stage, over load limit control three-floor lift operation plc interfacing and programming floor selection logic automatic stopping at floors direction indication system educational demonstration of elevator automation, mcb elcb trainer kit specifications: 1 phase/3 phase, 2/3/4 pole, 3a-16a single pole mcb 2-5amps two pole elcb 30ma lamp load single phase 5amps panel enclosure and terminal outlets, signal generator specifications: frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vp-p. rise time: 100 ns. distortion, dso specifications: bandwidth: 50 - 100 mhz. sampling rate: 1gs/s. channels: 2 (minimum) power supply: 100v 240v ac, 50-60 hz automatic measurement: vpp, vavg,rms, frequency, period, vmax, vmin, rise time, fall time, + width, - width, +duty, - duty etc., horizontal scale: 5 ns/div 50 s/div or equivalent vertical resolution: 8 bits (2 channels simultaneously) vertical sensitivity: 1 mv/div 10 v/div (at input) waveform math: +, -, x , , invert, fft etc., waveform storage: 16 waveforms or equivalent communication interface: usb host, usb interface. 7-inch color display or equivalent input impedance - 1 m 2%, // 20 pf 2 passive probes (1x/10x), pwm based
Tender For supply of equipment items - acidity test kit-ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications , 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated msenclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , linear variable differentialtransformer measurement trainerspecifications: input supply : 230 v ac, 50 hz type : linear variable differential transformer (lvdt) trainer kit lvdt stroke length : 25 mm led display provided digital voltmeter provided for output measurement potentiometer provided for calibration and adjustment signal conditioning circuit inbuilt zero adjustment and calibration facility provided test points provided for waveform/signal observation clearly labeled circuit diagram on front panel proper insulated terminals and safety sockets provided
Tender For supply of m.s. enclosure with all accessories for 20 fuse alarm system ( for twenty fuse) drg. no.s&t/by/f-346, 1,2 & 3. only valid iso:9001(qms) certified firm to quote. party to submit oem / authorization & test certificate with warranty.(shop no.09) [ warranty period: 30 months after the date of delivery ]