Get complete information related to latest Ms Enclosure Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Ms Enclosure Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Ms Enclosure Tenders.
Tender For providing, installation, testing and commissioning of electro-mechanical equipments at newly drilled t/well peerkho. - providing of 3 nos. submersible pump sets :- the job involves providing of 3 nos. submersible pump sets of specification 15000 gph x 80 m head of reputed make (one no. operational and two nos. standby) along with allied accessories to be installed in 10/12 inch dia. deep drilled new tube well peer kho. the job includes fabrication, providing and fitting of 2 no. clamps of span as per the required length to be fabricated and fitted with submersible pump sets with the help of heavy duty bolts and nuts (01 no. clamp to each pump set). the job also includes fabrication of 2 no. graded expander/ reducer for nrv of required size to be fabricated out of suitable thickness ms pipe threaded at one end and flanged at the other end. fitting of reducers/ expanders with 125 mm dia. column pipes at one end with flanged joint and with the discharge outlet of the submersible pumps at the other end.column pipes :- fabrication and providing of 125 mm dia. b class ms 20 nos. column pipes flanged on both ends. the length of each pipe shall be 3 mtrs. and shall be completely leak proof. the ms pipe shall be confirming to relevant isi specifications. the heavy duty flanges shall be furnished properly. one end of the flange shall be faced in such a way that a leak proof joint is made by providing and fitting a rubber sheet in between the two flanges and tightening it with nuts and bolts. each flange shall be provided with 6 no. equidistant holes of required dia. the job also includes welding of flat iron strips at each end for giving extra strength to the flanged joint and providing of 2 no. grooves on each flange on opposite sides for submersible cable to be accommodated though it. the welding of heavy duty flanges with the pipe should be carried out with superior quality pipe welding electrodes. then painting all the pipes with a coat of anti corrosive paint and two coats of super enamel paint. ms well cap, washout and riser pipe :- fabrication and fitting of ms well cap as per casing dia. of 8 mm thickness with one hole of approx 125 mm dia. in the centre and with holes/ cuts at an appropriate distance for passing submersible cable. providing and fitting of an arrangement for gi fitting near the discharge head outlet to provide water feeding to the gravel around the tube well casing. laying of delivery line for making of inter connections of top column pipe of new tube well by way of fabricating 900 ms bend out of 125 mm dia. ms pipe, welding of 2 no flanges one at each end. fabrication and fitting of 125 mm dia. ms pipe connection piece long as per site requirement with 90 degree bend with the help of nuts, bolts, washers, rubber sheet in between for leak proof joint. fitting of 1 no. 125 mm dia. heavy duty c.s. sluice valve through a connection piece as per site condition. fabrication, providing and fitting of 1 mm dia. heavy duty cast steel reflux valve. the sluice and reflux valve shall be confirming the isi standards and shall be of reputed make. fabrication and fitting of another 125 mm dia. connection piece flanged at both ends for working of washout by way of interconnecting delivery pipe through tee joint with the washout pipe.. fabrication and fitting of 1 no. blind flange at the end of washout. painting of exposed parts of the delivery line with two coats of anti rust primer and one coat of super enamel paint. the job also involves fabrication and fitting of one set of u-shaped clamps (for holding 125 mm dia. pipe) on the top column pipe for holding of column assembly on the casing and fabrication of 1 set of u- clamps to be used for extraction/ lowering of pump set along with column assembly. complete job includes cost of material, labour charges and carriage etc. and also making provision for wash out by providing and fitting of sluice valve of c.s of required capacity as per site conditions.lowering of submersible p
Tender For supply of supply of industrial grade cpvc 90 deg elbow size 1 inch. , supply of industrial grade cpvc ball valve size 2 inch. , supply of industrial grade cpvc blind flange size 2 inch. , supply of industrial grade cpvc cross size 1 desh 1 slash 2 inch. , supply of industrial grade cpvc flange size 2 inch. , supply of industrial grade cpvc reducer coupler size 1 desh 1 slash 2 x 1 inch. , supply of industrial grade cpvc reducer coupler size 2 inch x 1 slash 2 inch. , supply of industrial grade cpvc reducer coupler size 2 inch x 1 inch, as per astm f 439. , supply of industrial grade cpvc reducer coupler size 2 inch x 1 desh 1 slash 2 inch, as per astm f 439. , supply of industrial grade cpvc reducer coupler size 3 inch x 1 desh 2 inch , supply of industrial grade cpvc reducer coupler size 3 inch x 1 desh 1 slash 2 inch , supply of industrial grade cpvc reducer coupler size 4 inch x 2 inch. , supply of industrial grade cpvc reducer coupler size 4 inch x 3 inch. , supply of industrial grade cpvc reducing tee size 1desh 1 slash 2 inch x 1 slash 2 inch. , supply of industrial grade cpvc reducing tee size 3 inch x 1 inch
Tender For corrigendum : supply of on load change over switch 200a, 4 pole, 415vac, hz-50 with msenclosure, make-hpl electric / havells / philips [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : tender for supply of big vacuumpot and flange as per drawing no: ste-f24163-230/240 medium vacuumpot and flange as per drawing no: ste-f24163-250/260 blind suitable for tower ti cable stage, moc: ss304 as per drawing no: f24163-60 t1 cable stage blind adopter suitable for tower t1 for used in vacuum pot, moc: ss304 as per drawing no: f24163-50 t1 adapter medium adopter suitable for tower t2 for used in vacuum pot, moc: ss304 as per drawing no: f24163-40 t1 adapter big pot blind suitable for tower ti for used in vacuum pot, moc: ss304 as per drawing no: f24163-10 ti blind blind suitable for tower t2 for used in vacuum pot, moc: ss304 as per drawing no: f24163-30 t2 blind
Tender For corrigendum : cvp foundation items - manhole cover for cvp, discharge pipe cvp, discharge blind flange for cvp, suction embedded part cvp, suction embedded part cvp, motor sole plate cvp, discharge lip for cvp
Tender For three phase inductive load bank of transformer testing supply 415v ac, 4 wire, 50hz, maximum current 227a, resolution steps: 2 * 1 no, 10 amps * 1 no, 40 amps * 1 no, 50 amps * 1 no, 100 amps* 1 no, switchgears make: abb/siemens/schneider industrial msenclosure with ventilation [ warranty period: 30 months after the date of delivery ] ]
Tender For procurement of lab equipments for electrical and electronics engineering department - procurement of lab equipments for electrical and electronics engineering department., single phase tranformer: single phase transformer rating: 1 kva, 50 hz input: 230 v ac output: 115 v ac type: air-cooled, single-phase step-down transformer properly insulated input and output terminals brought out for safe operation, three phase transformer: rating: 3 kva input voltage: 415 v ac, 3-phase output voltage: 230 v ac, 3-phase frequency: 50 hz winding material: copper wound insulation class: class b or higher duty: continuous duty suitable for laboratory use bench/floor mounted suitable for laboratory operation. all winding terminals shall be brought out to insulated terminals and enclosed within a protective outer cover for safe laboratory operation , acidity test kit ethyl alcohol sodium carbonate solution universal indicator solution laboratory-grade test tubes droppers colour comparison chart for test result comparison chemicals supplied in labelled containers with safety instructions suitable for laboratory educational and testing applications, loading rheostat 3 phase: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , loading rheostat 01 phase: type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , single phase resistive load type: single phase loading rheostat power rating: 5 kw supply: 230 v ac, single phase, 50 hz total number of load steps: 8 approximate dimensions: 18 18 22 inches (l b h) comprising electrical load resistors suitable for laboratory loading applications resistors shall be special cement-insulated type mounted on powder-coated ms panel/enclosure individual on/off rotary switches provided for load selection mounted on rubber wheels/casters for portability , three phase resistive load: rating: 5.25 kw supply: 415 v ac, 3-phase, 50 hz total number of load steps: 6 main switch to be provided approximate dimensions: 18 18 22 inches (l b h) comprising special cement-insulated electrical load resistors mounted on powder-coated ms panel/enclosure individual on/off rotary switches for load selection mounted on rubber wheels/casters for portability suitable for laboratory load testing applications proper insulation, ventilation, and earthing arrangement to be provided , three phase capacitor bank: 3-phase capacitor bank rating: 2 kvar voltage: 440 v ac frequency: 50 hz heavy duty self-healing capacitor units powder coated msenclosure compact panel mounted/floor mounted construction proper ventilation arrangement to be provided capacitor duty contactor/switch to be provided fuse/mcb protection to be provided discharge resistors to be provided for safety proper earthing arrangement provided , on / off control of lamp using solid state relay kit type : solid state relay (ssr) trainer kit control/input voltage : 12 v / 24 v dc or up to 30 v dc output load voltage : 230 v ac, single phase load control : on/off control of ac lamp load solid state relay based switching circuit opto-isolated input control built-in ac lamp load manual on/off switching arrangement led indication for input and output status