Get complete information related to latest On Load Tap Changer Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic On Load Tap Changer Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding On Load Tap Changer Tenders.
Tender For corrigendum : research based pilot project [dynamic feeder voltage manager (dfvm)] for turnkey based work of design, development, supply, installation, testing & commissioning of 3-ph, 50 hz, 4000 kva, 12/12kv outdoor onan auto/power transformers equipped with on-loadtapchanger (oltc) with necessary infrastructure and protections, master controller and around 100 modems, control circuits with comprehensive maintenance contract for 05 (five years) after handing over the project
Tender For supply of 21.6/30.24 mva, 132/27 kv, traction power transformer, onan/onaf with onloadtapchanger, 50 hz, single phase as per rdso specification no. ti/spc/psi/trnpwr 3201 with a and c -1, str: ti-str-014 rev-06 [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : supply of 21.6/30.24 mva, 132/27 kv, traction power transformer, onan/onaf with onloadtapchanger, 50 hz, single phase as per rdso specification no. ti/spc/psi/trnpwr 3201 with a and c -1, str: ti-str-014 rev-06 [ warranty period: 30 months after the date of delivery ] ]
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off loadtapchangeron ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For providing of operation and maintenance power house / power plant - carried out in connection with complete overhaulingof 15mva, 15.75/6.9kv uat-10a & 10b along with onloadtapchanger of 200mw unit no.10
Tender For corrigendum : supply of 21.6/30.24 mva, 132/27 kv, traction power transformer, onan/onaf with onloadtapchanger, 50 hz, single phase as per rdso specification no. ti/spc/psi/trnpwr 3201 with a and c -1, str: ti-str-014 rev-06 [ warranty period: 30 months after the date of delivery ] ]
Tender For conversion of existing 50 mva, 220/33kv off loadtapchanger (+7.5% to - 7.5% in 7 equal steps) into onloadtapchanger (+5% to -15% in 16 equal steps) required for switchyards of takari lift irrigation scheme stage-ii. (total 1no.)
Tender For corrigendum : providing services overhauling and testing of on-loadtapchanger (oltc) make ctr and high voltage circuit breaker on-site at hbl plant sugauli
Tender For corrigendum : establishing 2x12.5 mva, 66/11kv sub-station at kalathmadu along with construction of proposed 66kv lilo line from the existing 66kv virajapete- ponnampete sc line on dc towers to proposed 66/11kv sub station at kalathmadu for a distance of 1.925km in virajpete taluk, kodagu district on partial turnkey basis including supply of all matching materials/equipments (excluding supply of 2x12.5mva 66/11kv power transformers and 11 kv switchgear) and erection (including civil works) of all materials/equipments, testing and commissioning - onloadtapchanger , control and relay panels, , circuit breakers, , 11kv mcvcbs & pcvcbs, , tower parts and all types of station structures with bolts, nuts and washers, , i beams & m.s channels, , lightning arrestors, , isolators, , insulators, , instrument transformers, , battery sets, , battery charger, , acsr conductors, , ground wire, , 11kv ug cable, , 1.1kv copper control cables & lt power cables, , capacitor bank, , hardware for insulator, conductor and ground wire:, , tension & suspension clamps and connectors., , accessories for conductor and ground wire:, , p.g clamps. m.s.c joints, pre-formed rods, repair sleeves, vibration damper etc., , c-type fire wedge connectors, , i) grounding materials (g.i flat, m.s flat etc.,), , il)grounding materials (c.i pipes), , ltac & dcdb panel, , 11kv termination & jointing kits, , class, , nitrogen injection fire protection, , system, , rigid tubular aluminium bus bars, aluminium clamps and connectors., , wave traps/line traps, , plcc equipment