Get complete information related to latest Square Bars Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Square Bars Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Square Bars Tenders.
Tender For supply of hydraulic installation tool with integral nose for placing 1" lock bolt. fitted with 01 meter thermoplastic flexible hose with end fittings of orione make ,model: ol i-25, max. pull pressure: 580 bar (8500 psi), max. return pressure: 220 bar (3000 psi), stroke: 45 mm, length : 222 mm, body diameter :140 mm, approx weight: 15.5 kg ( complete tool). [ warranty period: 12 months after the date of delivery ] ]
Tender For tender for supply of round ring , thermocouple , snap ring , spring washer , gasket , valve check , press relief valve , gasket , gasket , shaft , check valve , plate locking , gasket , shrinkage hose , eprom mpu24/mem5-02 programmed , screw , valve cap , tappet , temparature gauge electric , shaft rpm indicator , plug-in board , gasket , gasket , hose line with quick connection 1000 lg , cover , sk-05 power supply module , gasket , gasket , piston ring , filter/strainer , gasket , gasket , gasket , disc filter element , ring rubber , roller diaphagram , diffusser gasket , plug-in board , gasket , o ring , ezr 1712 element , nut m14x1.5 , pressure gauge , shaft seal , bolt hex a3c , snap ring 68 x 2 , 5 din 472 , snap ring 80 x 2.5 din 472 , valve cap , gasket , valve guide , gasket , gasket , gasket (135m01705/8) , valve , gasket leak off fuel , actuator , snap ring 24 x 1 , 2 din 471 , nut , copper profile (copper washer) , tab washer , valve guide , gasket , o ring 10x2 , o ring 12x2 , o ring 28x3.15 , o ring , gasket , metal gaiter , o ring 36x5 , o ring 135.89x659mm , pressure sensor 0-8 bar , shaft seal , friction washer , pressure gauge 0-10 bar , o ring , lock nut , seal fw pump , washer spring b10 , gasket , plug in sleeve , plug-in-board aib 1-02 , washer , gasket , valve non return , valve drain , rubber bellow , hp line , hp line , hp line b1 , hp line b3 , o ring 31x2.5 , hose line , valve non return , hp line b2 , o-ring , seat ring valve , thrust ring
Tender For supply of equipment items - dc motor:type: dc shunt motor (dismantling model) power: minimum 0.5 hp voltage: 220 v dc speed: 1500 rpm poles: 4 pole construction: laminated stator salient poles accessible armature features: cut section / open type suitable for dismantling and reassembly, hydraulic cylinder: bore diameter: 50 mm stroke length: 250 mm working pressure: 160 bar cylinder tube: honed steel piston rod: hard chrome plated seals: standard industrial seals end caps: steel supply: mounted on training base suitable for dismantling and inspection, hydraulic operated directional control valves (dcv):type: manual spool type dc valve configuration: 4/2 way size: ng06 (cetop 3) rated pressure: 210 bar flow capacity: 20 40 lpm body: hardened steel / cast steel spool: ground and hardened ports: clearly marked (p, a, b, t) supply: mounted on training plate suitable for dismantling and study, bearing with shaft assembly :type: dismantling and assembly teaching unit shaft diameter: 30 mm shaft material: en8 steel bearings: deep groove ball bearing (6205 / 6206) housing: cast iron locking arrangement: circlips lock nuts end covers mounting: bench-mounted / frame-mounted unit, coupling unit using driving and driven shafts using plummer block bearing unit :the plummer block housing material: cast iron (grade fg 200 or equivalent). type: sng or snl series (split-type housing). sealing: felt seals or v-ring seals (to demonstrate lubrication retention). lubrication: provided with a grease nipple at the top center for manual lubrication practice. the bearing type: self-aligning ball bearing (1200 series) or spherical roller bearing (22200 series). bore diameter: standard 25mm or 30 mm. shafting and coupling shaft material: ground carbon steel (en8 or en9) for high surface finish. coupling type: flexible coupling: to demonstrate the bearings ability to handle slight misalignment. rigid flange coupling: to demonstrate traditional direct connection. driving/driven setup: one shaft connected to a small electric motor (driving) and the other to a brake drum or load (driven).
Tender For supply, erection, testing & commissioning of lt panel consisting of 400a 50ka 4 pole microprocessor based mccb - 02 nos as incoming , 200a/250a 36ka 4 pole microprocessor based mccb-03 nos, 63a 36ka 4 pole microprocessor based mccb-02 nos and 63a 10ka dp 2pp mcb - 02nos as outgoing, all mccbs shall be with rotary switch, with voltmeter,ammeter, led indicator lamp,cu. bus bar , neutral link, earth bar, spreader link, lock and key feature arrangement cable gland etc. with suitable sheet steel enclosure conforming to cege/grc's specification no. ser/elec/gs/description/ltpanel/1/rev-0/mar2024 or latest.minimum size of panel 1800 mm (h)x 2400mm (l) x 600 mm(d). [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, installation, testing and commissioning of phase wire and street light and vairious electrical equipment needed for implementation of budget announcement 2025-26 - providing & fixing of ik08, ip 66 protected led street light luminaire on existing bracket/pole. fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with uv stabilized pc (uv stablization report submitted for uv cover ) /toughened glass cover and secondary lens on each led & should be smd type of 3 to 5 watt each . the system efficacy >=125 lm/ wt and potted driver & has a unique bis r number with input voltage ac 120 to 270 v ac with high voltage cutoff @>=300 v ac and auto resetting safety , power factor >0.95 driver efficiency >85% ,thd(i) 70 and cct 5700k +355k. surge protection shall be min 4 kv internal and min 10 kv external inside driver compartment. driver should be phase to phase protection of 440 v for 4 hrs. manufactures word mark/name engraved/embossing on die cast housing to allow traceability/authenticity. fixture shall be as per is 10322 complianced.oem must have its own in, led street light fixture with minimum lumen output 5600 lm, sitc of ip-42 and general construction confirming to is:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)thickness of crca sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, water rinsing, activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then powder coated with approved shade of minimum 70 microns on both side of panel. the panel having pe foam/ neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 sq.mm, earth wire with 2.5 sq.mm and ct with 2.5 sq.mm flexible copper wire only. all joints / interconnections of copper bus bar shall be dully tinned . clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar bus bar is insulated by heat shrinkable sleeves . earth and neutral bus bar shall be half of the size of phase bus bar. ( cost of bus bar / flexible wire for interconnection between main busbar and switchgear is to be paid extra )(d)wiring between components within switchgear and incoming / outgoing cable shall be done through the terminal block only. direct connection shall not be permitted. each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. for tap-offs, adjacent terminals with shorting strips shall be used. 10% spare terminal blocks shall be provided. wire identification on marking strip shall correspond to the designation of the wiring diagrams. all wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram.(e)all wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, wiring between terminals of various devices shall be point to point (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)floor mounted panel sh