Web Analytics Made Easy - StatCounter

Terminal Post Tenders

Get complete information related to latest Terminal Post Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Terminal Post Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Terminal Post Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43191159 Due date: 25 Dec, 202525 Dec, 2025 76.0 Thousand
Tender For repairing and rewinding and failed parts new changing self startor 24v delco remy 6 pole 50mt alternator 24v delco remy 160 amps for drill rel-650 sl no-511 and idm30 6863at ant st kujama ocp, lodna area., bccl.

corporations/Associations/Others

CTN :43169620 Due date: 23 Dec, 202523 Dec, 2025 NA
Tender For work for replacement damaged pcc/st pole under edd fatehpur

CTN :42988395 Due date: 18 Dec, 202518 Dec, 2025 1.00 Crore
Tender For corrigendum : maintenance- repairs- replacement of electrical items for various projects executed under srinagar smart city limited for a period of 2 years. - supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage, delivery and erection of following sizes of distribution transformer at site., i) 630 kva distribution transformer, ii) 400 kva distribution transformer, iii) 250 kva distribution transformer, iv) 100 kva distribution transformer, v) 63 kva distribution transformer, fixing of fabricated gi angle/channel/flat/pole collars., fixing of galvanised nuts and bolts., supply, installation, testing, commissioning, insurance, unloading, carriage and delivery at site, laying, stringing and binding of conductor including joints with pg clamps of required following size of acsr conductor (0.1 /0.05/ 0.03), i) 100 sqmm acsr (dog), ii) 50 sqmm acsr (rabbit), iii) 30 sqmm acsr (weasel), supply, installation, testing, commissioning of ab (ht) cable of following sizes:, iii) 50 mm ab (ht) cable (3x50+1x70 mm ) xlpe(11 kv, 3c +earth), iv) 70 mm ab (ht) cable (3x70+1x95 mm ) xlpe(11 kv, 3c +earth), v) 95 mm ab (ht) cable (3x95+1x95 mm ) xlpe(11 kv, 3c +earth), vi) 120 mm ab (ht) cable (3x120+1x95 mm ) xlpe(11 kv, 3c +earth), mid span straight through jointing kit for 11 kv abc of following sizes:, i) 11 kv abc 50-95mm straight through jointing kit (3 core), ii) 11 kv abc 120-185mm straight through jointing kit (3 core), iii) 11 kv abc 240-300mm straight through jointing kit (3 core), heat shrinkable outdoor cable termination kit for ht/lt abc of following sizes:, i) 11 kv abc 70-95 mm outdoor cable termination kit, ii) 11 kv abc 120 mm outdoor cable termination kit, iii) 11 kv abc 150-185 mm outdoor cable termination kit, iv) 11 kv abc 240-300 mm outdoor cable termination kit, supply, installation, testing, commissioning of ab (lt) cable of following sizes:, ii) 50 mm ab (lt) cable ( 3x50 + 1 x 16 + 1 x 35) mm xlpe (1.1kv, 3+1 c, al), iii) 70 mm ab (lt) cable (3 x 70 + 1 x 16 + 1 x 50) mm xlpe (1.1kv, 3+1 c, al), iv) 120 mm ab (lt) cable (3 x 120 + 1 x 25 + 1 x 95) mm xlpe (1.1kv, 3+1 c, al), straight through cable jointing kit for lt abc of following sizes:, ii) 50 mm ab (lt)straight through cable jointing kit, iii) 70 mm ab (lt)straight through cable jointing kit, iii) 120 mm ab (lt)straight through cable jointing kit, dismantling, i) dismantling, stacking of 9/8 mtr st poles and transportation back to divisional store as per the instruction of electrical incharge., ii) dismantling of 0.03/0.05/0.1 acsr conductor and transportation to divisional stores (servicible), servo voltage stabilizer, i) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 63 kva, 3-phase oil cooled servo (complete job), ii) supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 50 kva, 3-phase oil cooled servo (complete job), rmu, supply, installation, testing, commissioning including loading, transportation, insurance, unloading, carriage and delivery at site and erection of 4 way type,two isolators and two circuit breakers 11 kv, ring main unit ,sf6 insulated, out-door type, extensible type,breaking capacity 25 ka for one second with sf6 circuit breaker / vcb self powered with o/c + e/f relay comprising of a) 11kv 630 amp motorised isolator including earthing switches with making capacity 52ka, having mechanical on/off, earth indications with fault current indicator.b) 11kv ,400 amp motorised spring operated, circuit breakers with earthing switches, connecting the rmu to supply transformer. c). copper bus bar of 630 amp rating.d). 1 no numerical aux. powered relay having non directional o/c and e/f protection (for each ciruit breaker).d). the circuit breaker enclosures shall be outfitted with a communicable-type numer

corporations/Associations/Others

CTN :43177129 Due date: 08 Jan, 202608 Jan, 2026 2.99 Lacs
Tender For development of st ltg arrangement with pole and led light fitting 4/73 , 4/66 , 4/18a, 4/10 4/18 4/15 4/2 4/13 netajinagar in ward 98, br-x 152/190.

CTN :43033958 Due date: 17 Dec, 202517 Dec, 2025 NA
Tender For corrigendum : the work of shifting of line full deposite scheem at various place under edd-sadabad hathras. - safe carriage of following material from electricty store center hts to pit site of work through the kacha and pakka road including loading and unloading at the respective ends including the cost of arrangement of labour, t&p, etc. which required for proper completion of work.(distance 00-50 kms.), 8.5/9 mtr. long pcc poles., 9/11 mtr. s.t. poles, acsr weasel conductor, earthing complete, shackle insulator, stay set complete, teoff channel, 33/11 kv pin insulator with pin, disc insulator with disc fitting, f bracket, 11 kv x-arm, 50/95/120 sqmm. ab cable, suspension clamp, dead end clamp, distribution box with clamp, pearcing connector, guarding angle with clamp, g.i wire 6/8/10 swg, neutral cum earth wire, cable jointing kit, 11 kv xlpe cable, 25 kva t/f, 63 kva t/f, 100 kva t/f, errection of following poles including cutting of kharanja/mettalic road/concrete portion while digging pit & complete h.t./l.t. fittings as per respo manual and as per direction of engineer incharge including the cost of labour, t&p and carrier etc. required for proper completion of work., pcc poles 8.5/9 mtr., stp 9.0/11 mtr., errection and grouting of stays as per respo norms and as per direction of supervising engineer. grouting material i.e. cement, sand, brick ballast/stone ballast etc. shall be arranged by the contractor at his own cost., fixing of earthing rod as per respo norms and as per direction of supervising engineer., safe installation of following new/repaired cousted t/f on newly constructed double pole in proper alignment direction & making all ht/lt connection., 25 kva t/f, 63 kva t/f, 100 kva t/f, laying, sagging and stringing and jumpering / binding etc. of new & old acsr weasal conductor / gi in 11 kv / lt lines as per respo manual and as per direction of supervising engineer., acsr weasal conductor, 50/95/120 sqmm. ab cable, xlpe cable, providing & fixing of following clamps, 11 kv x arms clamps for stp/pcc pole, nut,bolt & washer, 11 kv f clamp for stp/pcc pole, earthwire clamps, lt clamp with nut & bolt, cable jointing kit, cutting, chopping, triming of tree branches to clear the line route to give 2 mtr. horizontal and vertical clearance to the line coming in the route of different feeders as per direction of supervising engineer, guarding/reguarding of 11 kv line by laying, stringing, sagging and binding of 2 nos. parallel gi wire 6 swg after providing, fabrication and fixing of guarding angle and fabrication and fixing of x-guards (tillis) of gi wire at distance of 3 mtr., installation of extra t on the erected poles wherever required alongwith all fitting as per direction of supervising engineer including the cost of labour, t&p etc, required for proper completion of work. the "t" pole shall be grouted with cement, sand and brick ballast/stone ballast in ratio 1:4:8 including the cost of material., dismentlling and removal of existing line from the various area, dismentlling of pole stp/pcc, back cartage, acsr weasel conductor scrap, iron scrap

CTN :43130429 Due date: 17 Dec, 202517 Dec, 2025 36
Tender For tender for supply and maintenance of street lighting equipment in all villages under kotehal gram panchayat including sc and st colonies 2025-26 - vrd_ktl_sl//cfl set 45 w , vrd_ktl_sl//led bulb 18 w , vrd_ktl_sl//led bulb 20 w , vrd_ktl_sl//led bulb 24 w , vrd_ktl_sl//led set 50 w , vrd_ktl_sl//led set 30 w , vrd_ktl_sl//plastic bulbs cover , vrd_ktl_sl//led set 100 w , vrd_ktl_sl//flood light 100 w , vrd_ktl_sl//flood light 150 w , vrd_ktl_sl//flood light 250 w , vrd_ktl_sl//street light off and on handle switch 32 a , vrd_ktl_sl//mcb 4 pole , vrd_ktl_sl//mcb 3 pole , vrd_ktl_sl//mcb 2 pole , vrd_ktl_sl//single pole mcb , vrd_ktl_sl//screw driver , vrd_ktl_sl//dp switch , vrd_ktl_sl//ceiling fan , vrd_ktl_sl//wonder tape role , vrd_ktl_sl//copperwire coil 2.5mm , vrd_ktl_sl//alluminium coil 4.0mm , vrd_ktl_sl//alluminium coil 6.0mm , vrd_ktl_sl//copperwire coil 1.0 mm , vrd_ktl_sl//cutting player , vrd_ktl_sl//tester , vrd_ktl_sl//c g holdr , vrd_ktl_sl//c f l holdr , vrd_ktl_sl//stret clamp , vrd_ktl_sl//stret bend pipe , vrd_ktl_sl//bulb led 12 w , vrd_ktl_sl//bulb led 15 w , vrd_ktl_sl//contactor 32 a , vrd_ktl_sl//fm1q timer , vrd_ktl_sl//spn 32amcb , vrd_ktl_sl//syntex panel board 12/18

Central Government And Public Sector

CTN :43116013 Due date: 30 Dec, 202530 Dec, 2025 18.98 Lacs
Tender For purchase of spares from the original manufacturer for 11kv vcbs (model vm12) of bhel make. - closing unit assembly, tripping unit assembly, motor cut-off limit switch assembly, mechanism shaft assembly, tripping spring assembly, closing spring set, top pole head, bottom pole head, spring charge motor 220v (ac/dc), operating coil 220v (dc), vcb support insulator ø118, panel / busbar support insulator ø75, lever for vi, drive link, d-lever assembly, centering ring, spherical rod end, spacer tube, support rod, compression spring, aux switch 16 way, emergency tripping assembly, plug & socket assembly (male + female)-32 pin (indoelectricals make), slow closing handle, motor charging handle, packer cu, flexible connection up to 1600a, bearing, rollers, dashpot, set of clips, indicator, truck nylon wheels, nylon rollers for shutter lifting, bolt for truck wheel, jaw contact assembly up to 1600a, jaw contact square cu packer, manual knob push button (red), manual knob push button (green), damping rubber pad, auxiliary rod, swing bolt, actuating arrangement, cam shaft for rack-in/out, 52c/d auxiliary bracket, vcb interphase barrier, jaw contact polycarbonate shroud up to 2500a, insulating coupler, door gasket (4.4 mtr/panel), door lock assembly, door glass, interpanel busbar smc sheet barrier, shutter arrangement, limit switch test/service, tripping lever/knob, cleat, nut, insulating screw m6x22, rear cover polyamide handle, packer (round), al spacer (round), support insulator 095, support channel, busbar screw (special), steel stud, clamp plate, packer, link plate inplace of droppers al, barrier, sealing cover, busbar joint pvc shroud, support channel round packer, earthing connection, pvc sleeve l/f 0.4x104 for 75wd busbar, pvc sleeve 38p for wiring, space heaters 75w, bolt hex m12x75-8.8, bolt hex m12x65-8.8, nut hex m12x8, washer spg-12-st, washer mcd 13-st, screw hex m8x30-8.8, washer spg-8-st, washer mcd 8.4-st, nut hex m8-8, m20 bolts for support insulator, nylon m5 screw, nylon m5 nut, screw hex m6x20-8.8, washer spg lock 5cb-6-5t, washer mcd 6.4-st, nut hex m6-8, bolt hex m16x65-8.8, washer spg lock scb 16-st, washer mcd 17-st, thol/con 220vdc thermal overload relay with power, contactor having 1nc aux. contact., dc diode plate, barrier for top fixed contact, barrier for bottom fixed contact, large barrier between ct

corporations/Associations/Others

CTN :42966947 Due date: 15 Dec, 202515 Dec, 2025 5.00 Lacs
Tender For corrigendum : replacement of damaged pole erected in various line in unforeseen circumstance under eudc 1 noida - details of work and quantity against e-tender no. 32/eudc-i/2025-26/noida (works) for carrying out the work replacement of damaged s.t./ p.c.c. pole erected in various h.t./l.t. line in unforeseen circumstance (all type of labour will be providing by the contractor) on time to time for the period of 06 months in area of eudsd-i/ii/iii/iv/viii/ix/xiii, noida under eudd-i/v/vii, noida in the juridiction of eudc-i, noida.

State Government

CTN :43107483 Due date: 16 Dec, 202516 Dec, 2025 2.35 Lacs
Tender For supply, installation, testing and commissioning of 1x40 watt led single pole solar light including supply and errection of 7.0m st pole (ms) to be installed (09 nos) at notun para oktiya mosjid and gorosthan at ward no- 17

State Government

CTN :43107488 Due date: 18 Dec, 202518 Dec, 2025 1.83 Lacs
Tender For supply, installation, testing and commissioning of 1x40 watt led single pole solar light including supply and errection of 7.0m st pole (ms) to be installed (07 nos)
 Loading, Please wait...

Connect us via What's Up