Get complete information related to latest Bus Bar Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Bus Bar Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Bus Bar Tenders.
Tender For upgradation of existing scada /sas system and restoration of bus bar protection (hardware and software) at 220/132/33 kv gss ulijhari (chaibasa-i) including comprehensive annual maintenance contract for the period of five (5) years
Tender For supply of set of bus bar and accessories for wag-9 hc (pannel section) to spec.drg. no. clw/es/3/0118/m (set details: as per specification attached). note:- this material must be purchased from clw approved sources only. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply and end termination of over load current protection system along with full end termination suitable for overload and short circuit protection along with miniature circuit breaker distribution board with eight way mcb capacity 415 with busbar rating 200a v, c type rated sc capacity 10ka confirming tois: 13032:1991 latest with housing powder coating siemens grey-7035 with bimetallic terminal connector suitable for 16 dia aluminium tubular busbar for 32a copper palm copper cu etp cw 0041a and aluminium barrel aluminium al 99.5 cable connector temperature resilience, corrosion resistance size: 16 sqmm confirming to is: 5561-1970 with maximum temperature rise of 90 degree celsius. material shall be confirmed todesignation a6 of is: 617-1959. breaking resistance for barrel 85 n/m sq m and for palm 225 n/m sq m with stretching a5% for barrel must be for palm 16. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply, fixing, testing and commissioning of 100 kvar apfc panel, with crca sheet of thickness 2.00 mm with 7 tank process powder coated, ip-54 consisting of the followings:- (1) main mccb 250 amp 3 pole 35/36ka - 01 no., (2) main copper bus bar tpn 400a capacity -01 set, (3) apfc relay 8 stage - 01 no. (4) led indicator r/y/b -03 nos, (5) mccb 100 a 3-pole 10 ka -02 nos. (6) mcb 40 a 3-pole 10 ka -02 nos.(7) mcb 32 a 3 pole 10 ka-01 no. , (8) mcb 20 a 3-pole 10 ka - 01 no., (9) mcb 10 a 3 pole 10 ka - 01 no. (10) mcb 6 a 3-pole 10 ka - 01 no. (11) contactor capacity duty type:- moc 25 for 25 kvar - 02 no. (12) moc 15 for 15 kvar- 02 no(13) moc 10 for 10 kvar -01 no. (14) moc 05 for 05 kvar -01 no.(15) moc 03 for 03 kvar -01 no.(16) moc 02 for 02 kvar- 01 no .(17) heavy duty capacitor :- 25 kvar - 02 no, 15 kvar- 02 no., 10kvar-01 no. 05 kvar - 01 no., 3kvar- 01 no., 2kvar - 01 no. (18) auto manual selector switch -08 nos. (19) led indicator on off- 16 nos. (20) control and power cable frls copper , ( 21) ct-as per requirement, including all accessories for commissioning complete in all respect as per direction of sse in-charge, test report from govt. lab/nabl /ilac lab to be submitted at the time of supply. specification as per iec 61921/ is 8623/ is 16636/ iec 61439. make abb/ havells/ l&t/siemens or similar. [ warranty period: 30 months after the date of delivery ] ]
Tender For supply of point insulation complete set as per rdso/spn/168/2005 revision 2.0 or latest for 1.switch bracket d bracket insulation for irs point machine - one set comprises of (a)side plate lh to drg.no. s-3266 - 1 no. (b) side plate rh to drg.no. s-3265 - 1 no. (c)insulating bush to drg.no. s-23199 - 4 nos. (d) insulating washer to drg.no. s-8640 - 4 nos., 2. split-stretcher bar 2.1 insulation for leading stretcher bars (bg) each set comprising of (a) insulating plate for leading insulated stretcher bars bg as per rdso drg.no. t-10384 -2 nos. (b) insulating bushing for leading insulated stretcher bars for bg as per rdso drg.no. t-10368- 4 nos. (c) insulating washer for insulated stretcher bar bg as per rdso drg.no. t-10371 - 6 nos. 2.2 insulation for following stretcher bars bg. each set comprising of: (a)insulating side plate for insulated stretcher bars bg as per rdso drg.no. t-10367 -3 no. (b) insulatingbushing for insulated stretcher bars bg as per rdso drg.no.. t-10368 - 6 nos. (c)insulating washer forinsulated stretcher bars bg as per rdso drg.no. t10371 - 12 nos & 3. gauge tie plates (52 kg/60kg as per site requirement) insulation for (bg) complete with insulating bush and washer each set comprising of: (a) insulating plate for insulated tie plate bg as per rdso drg.no. t-10372-1 no. (b) insulating bushing for insulated stretcher bar bg as per rdso drg.no. t10368 - 3 nos. (c) insulating washer for insulated stretcher bar bg as per rdso drg.no. t-10371 - 6 nos. spec:rdso/spn/168/2005 [ warranty period: 30 months after the date of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For corrigendum : strengthening of 66kv subst... - strengthening of 66kv substation aurangabad by augmentation of existing 66kv single bus bar to 66 kv double bus bar at 66 kv sub-station ais aurangabad palwal (detailed activity as per boq provided in the tender document)
Tender For supply, installation , tesgting , commissioning of cold storage room (equipment) in the old boys hostel at central university of tamil nadu, thiruvarur - coold storage room size (18l *11w * 9h) feet, supply of puf panels, door, refrigeration unit, control panel with accessories, installation charges of puf panels, doors & refrigeration units, labour charges for loading, unloading, labour charges for copper piping laying work, n2 pressure test, leak test, leak arrest, again n2 pressure hold, vaccuming, gas charging and commissioning of the unit, additional refrigeration pipe with accessories, transport charges, supplying and fixing of following sizes of water pipe of upvc ( sch 40) conduit along with accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required., 25 mm, electrical work, supplying and fixing of following ways surface/ recess mounting, vertical type, 415 v, tpn mcb distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 a tinned copper bus bar, common neutral link, earth bar, din bar for mounting mcbs (but without mcbs and incomer ) as required ., 12 way (4 + 36), double door (power & ups), providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, ics=100% icu and operational voltage 690v etc. as required., 100 a, 16 ka,tpmccb , supplying and fixing following rating, four pole, 415 v, mcb in the existing mcb db complete with connections, testing and commissioning etc. as required., 63a, supplying and fixing 30 a, 415 v, tpn industrial type socket outlet, with 4 pole and earth,metal enclosed plug top along with 30 a"c" curve, tpmcb in sheet steel enclosure,on surface or in recess, with chained metal cover for the socket out let and complete with connections, testings and commissiong etc required, 4 x 16 sq. mm + 2 x 6 sq. mm earth wire (incommer for power & ups line to db box)