Get complete information related to latest Duct Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Duct Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Duct Tenders.
Tender For supply of rmpu drain duct assembly for pp2 coaches to drg no: 82810004 alt 'nil'- 1 no.special condition : suitable packing to be done to prevent damage during transit unloading and rust prevention during storage. (safety item) [ warranty period: 30 months after thedate of delivery ][quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Tender For supply of transition duct assembly for machine room ventilation of wag-9hc loco. as per clw/ms/03/159 alt.nil. drg.no.1209-11.244-024 alt.4 or latest. ]
Tender For work of replacement / repair of pa duct, mixed air duct and expansion joints from pa header to coal mill scraper area of coal mill xrp 1043 during aoh of unit-8 c.s.t.p.s. chandrapur
Tender For supply, installation & commissioning of industrial kitchen chimney, material: stainless steel,mounting type: wall mount, length of stainless steel hood: 16 feet, thickness of stainless steel hood: 22 gauge 202 grade, axial fan 1 hp 20 inch: 03 nos, motor speed: 1440 rpm, 230 v, 50 hz, gi cooler with honey pad: 01 set, ventilation type:ducted, thickness of gi duct: 0.63 mm, gi duct frame: 24 gauge, ducting area: 960 sqf with hot air and fresh air, complete with all accessories. [ warranty period: 12 months after the date of delivery ] ]
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cable end box, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For corrigendum : tender document for procurement of hdpe duct and associated accessories on pan india basis - supply of hdpe duct 40/33 mm as per technical specifications given in tender, supply of push fit couplers (40mm) as per technical specifications given in tender, supply of end caps as per technical specifications given in tender, supply of simplex plugs as per technical specifications given in tender