Get complete information related to latest M R I Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic M R I Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding M R I Tenders.
Tender For corrigendum : request for proposal for development, operation and maintenance of radiology imaging diagnostic centers for ct and mri scan services in selected civil hospitals of haryana on public private partnership basis
Tender For corrigendum : tender for supply and installation of mri machines in district hospitals on an in-house model under the ecrp-2/nhm-nfds grant under the national health mission free diagnostic services programme
Tender For corrigendum : supply of fqa lab mechanical for lara and talcher project d d -- magnetic particle inspection yoke type-02 nos, pie gauge for mpi-02 nos, radiography film densitometer-02 nos, uv lamp for fluorescent mpi and dpt-02 nos along with all accessories , group-5 - stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-02 days in talcher and 02 days in lara , group-5 - site visit - - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site-01 visit in talcher and 01 visit in lara , group-6 - radiation survey meter-02 nos, personal digital dosimeter-04 nos, ultrasonic testing machine-conventional with probes and calibration blocks-02 nos with all accessories , group-6- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-02 days in talcher and 02 days in lara , group-6 - site visit - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site02 visit in talcher and 02 visit in lara , group-7- digital radiography-02 nos along with all accessories , group-7stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-04 days in talcher and 04 days in lara , group-7 - site visit - - should include travel expenses to-fro site, visainsurance-if applicable, intermediary stay- for sup of e and c etc at site-02 visit in talcher and 02 visit in lara , group8- optical microscope for replica interpretation,optical microscope and image analysis system, stereo microscope with camera attachment-02 nos , group-8- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-01 days in talcher and 01 days in lara , group-8- site visit should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site02 visit in talcher and 02 visit in lara , group-9- computed radiography-cr-scanner-02 nos-alongwith all accessories please refer price schedule , group-9- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-04 days in talcher and 04 days in lara , group-9- site visit - - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site-02 visit in talcher and 02 visit in lara , group-10- hardness tester rebound type-02 nos and hardness tester_uci method-02 nos-along with all accessories , group-10- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-02 days in talcher and 02 days in lara , group-10- site visit - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site01 visit in talcher and 01 visit in lara , group-11radiography film viewer-04 nos, radiography film samplesasme-02 nos , magnetic particles inspection-coil type with cable-02 nos, gaussmeter for mpi-02 nos, ni-cr panel for dpt-02 nos , group-11- stay at site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-02 days in talcher and 02 days in lara , group-11- site visit - - should include travel expenses to-fro site, visa- insurance-if applicable, intermediary stay- for sup of e and c etc at site-01 visit in talcher and 01 visit in lara , group-12-pls refer item description and price schedule for details_holiday detector, stethoscope, vibration meter, comparator, roughness meter, noise meter, torque wrench etc , group-12- stay at //bid details2 / 46site including lodging, boarding, local conveyence etc for supervision of erection and commissioning etc at site-10 days in talcher and 10 days in lara , group-12- site visit - should
Tender For corrigendum : technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulse generator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulse generator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulse generator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulse generator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulse generator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulse generator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system shou