Get complete information related to latest Cable End Box Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Cable End Box Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Cable End Box Tenders.
Tender For corrigendum : : supply, installation, testing & commissioning of electrical equipment for dg block 119a of inrp - ht panels (119a)supply, installation, testing & commissioning of indoor type floor mounted, single front, metal clad, 1250 a, 6.6 kv, 3 phase, 3 wire, vcb switchgear panel suitable for a short circuit current of 31.5 ka for 3 seconds, internally arc tested for 31.5 ka for 1 second, comprising of following incoming & outgoing feeders : incoming feeder: 1 no. 1250 a, 3p vcb outgoing feeders: i) 7 nos. 630 a, 3p vcbii) 1 no. 1250 a, 3p vcb as tie feederwith surge arrestors, relays, pts, cts & other necessary accessories including associated structural steel required for complete installation of the panel & equipment earthing of the panel from both the earthing terminals of the panel to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings. reference drg. nos: ip1/119a/05027339/dwg/001/r0 & ip1/119a/05027339/dwg/002/r0(note: terminal box of each incomer of 6.6kv switchboard shall be suitable for terminating 4x3cx400 sq.mm., 6.35/11kv (e), a2xwy cables.), supply of spares for ht panels as per attached spares list mentiond in section c, part ii of tender, 2.5 mva, 6.6/0.433 kv dry type transformers (119a)supply, installation, testing & commissioning of 6.6/0.433 kv, 2.5 mva, dyn11 dry type cast resin transformer having percentage impedance of 8.5% complete with ht cableendbox, lt bus duct flange, off load tap changer on ht side with range of +/-5% in steps of 2.5%, wti scanner, ct for restricted earth fault protection and other necessary accessories including associated structural steel required for complete installation of the transformer & equipment & neutral earthing of the transformer from both the earthing terminals of the transformer to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & drawings.reference drg. no. : ip1/119a/05034347/dwg/001/r0, supply of spares for dry type transformers as per attached spares list mentiond in section c, part ii of tender, 2000 kva diesel generator sets (119a)supply, installation, testing & commissioning of 3 phase 2000 kva prime power 433v, 50hz, 0.8 p.f. diesel-generator sets with 110% overload capacity for 1 hr with four (4) stroke inline or vee type cylinder arrangement having engine speed 1500 rpm, 24v electric battery starting system with a provision of interchangeability of battery bank between two dg sets, complete with all auxiliary equipment including amf control panel, auxiliary mcc panels, heat exchanger cooling system, raw water pump, remote radiator with fans on terrace, ms exhaust piping, exhaust structure (maximum 30 m stack), 4 nos. of 3.6 cubic metre fuel day tank outside dg building (for all 4 dg sets) & 1 no. of 990 ltr intermittent tank inside each dg room, ms "c" class fuel piping between engine & fuel tank, dg room accoustic treatment & complete ventilation of dg room, brushless excitation for alternator, one no. 3200 amp 415 v 4p acb, ms structural steel supports/ channels/ angles & other necessary accessories including associated structural steel required for complete installation of the dg & equipment & neutral earthing of the dg from both the earthing terminals of the dg to the nearest earthing grid conductor existing at site using copper conductors of size as per tender technical specifications & necessary statutory clearances from cpcb etc. as required and as per tender technical specifications & drawings. design and construction of foundation for exhaust pipe rack/ structure of dg set is included in the scope of the contractor.reference drg. nos. : i) ip1/119a/05034347/dwg/001/r0ii) ip1/119a/05044831/dwg/003/r0iii) ip1/119a/05044831/dwg/004/r0iv) ip1/119a/05044831/dwg/005/r0v) ip1/119a/05044831/dwg/006/r0, supply of sp
Tender For supply of gear pump and flow divider - gear pump gabella code 00630009 , sealkit for hyd pump xv 2p 17 , flow divider code 9rd 02 20 , repair kit for flow divider 9rd , pump kw1 p1 2 multi slitter hyd power , seal kit for hyd pump xv 1p 1 2
Tender For supply of sluice valve 200mm pn1 point 6 isi marked , sluice valve 150mm pn 1 point 6 isi marked , pump starter 12 point 5 hp delta isi marked , ht tape 3m 19mmx9mtr , ht tape 3m 25mm x 10mtr roll , non return valve 150mm isi marked , led garden light 10w , sluice valve 100mm pn 1 point 6 isi marked , led bulb 7 watts , cable copper pvc frlsh 2 point 5 sqmm multistranded single core , sluice valve 80mm pn 1 point 6 isi marked , sensor based led tube light batten 20w , heating element 1500 watt triangular type , non return valve 100mm isi marked , heating element 2000 watt triangular type , ht cableendbox outdoor 3 c x 95 sqmm 11 kv e , led driver for 2 feet x 2feet false ceiling light fitting , ht cableendbox indoor 3 c x 95 sqmm 11 kv e , heat strinks joint kit indoor 3c x 95 sqmm , cable copper frlsh pvc 1 point 5 sqmm multi stranded single core , submursible cu cable 16 sqmm x3core isi marked , submursible cu cable 25 sqmm x3core isi marked , sheet metal enclosure with plug top and mcb sp 20a , pvc flexible cable frlsh 0 point 5 sqm three core , pvc flexible cable 23 oblique 00076 twin core , led tube rod 20w essential 1200mm 2100 lm , thermostat for geyser 25 ltr , led electronic driver 150 w , led electronic driver 100 w , fan regulator switch type , mcb 63 amp 4 pole isolator , pvc flexible cable frlsh 1 point 5 sqm three core isi marked , mcb 40 amp 4 pole isolator , cable copper frlsh 1sqmm single core isi marked , mcb 32 amp 4 pole isolator , led electronic driver 45 w isi mrked , thermostat for geyser 50 ltr isi marked , 20amp plug and socket distribution board , modular socket with mcb sp 25a , regulator electronic for ceiling fan modular type , fan regulator dimmer 400 oblique 450w , switch socket combination 6a , led driver 90w , led electronic driver 72 w , mcb sp 06 amp 230 volts 10 ka , led tube light fitting 20 w alum extruded decorative box with driver and tubelight , led bulb 9 w 230 volt with electric backup battery , led tube light fitting 18 w alum extruded decorative box with driver and tubelight //bid details 2 / 136
Tender For consultancy work of civil work like rcc trimix road, asphalt road, paver block road, footpath, divider, traffic circle, street light, all type of building like community hall, party plot, complex, library building , gymnasium building, crematorium development, new garden development, beautification, solar power system, cctv camera, water supply, underground drainage, strom water drain, solid waste management etc. development related project work for various scheme
Tender For consultancy work of civil work like rcc trimix road, asphalt road, paver block road, footpath, divider, traffic circle, street light, all type of building like community hall, party plot, complex, library building , gymnasium building, crematorium development, new garden development, beautification, solar power system, cctv camera, water supply, underground drainage, strom water drain, solid waste management etc. development related project work for various scheme.
Tender For distribution transformer of rating 500 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, on load type tap changer for variation of hv voltage from +5% to -15% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, confirming to is 1180 (part 1): 2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest with condition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall confirm to is/iec 60137. the low voltage bushings (4 nos.) shall confirm to is 7421. suitable cable-endbox along with cable entry hole glands is tobe provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is 1180 (part 1) latest. (ii) routine test certificates as per is: 1180(part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d), (e) of is: 1180 (part 1) latest. bee star rating:- 3 or above (firm shall submit a valid bee certificate for the offered product with desired bee star rating). [ warranty period: 30 months after the date of delivery ] ]
Tender For single range moving coil dc portable voltmeter , single range moving iron ac or dc portable voltmeter , digital multimeter , analog multimeter , digital logic trainer , wheatstone bridge portable , construct a circuit to measure ac voltage by voltage divider method , lvdt trainer kit , thermistor characteristic apparatus , speed measurement module using magnetic sensor , dc regulated power supply single channel , cathode ray osciloscope
Tender For consultancy work of civil work like rcc trimix road, asphalt road, paver block road, footpath, divider, traffic circle, street light, all type of building like community hall, party plot, complex, library building , gymnasium building, crematorium development, new garden development, beautification, solar power system, cctv camera, water supply, underground drainage, strom water drain, solid waste management etc. development related project work for various scheme
Tender For bid to ras providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - fm transmitter; taking down the antenna and rf power divider from the 100 meter gi mast and after repairing reinstalling it on the mast; service provider
Tender For distribution transformer of rating 250 kva, 11kv/415v-240v, 3-phase, 50hz, outdoor type, plinth mounted, the type of tap changer: off-load tap changer for variation of hv voltage from +5% to -10% in steps of 2.5%, energy efficiency level 3 or better, oil immersed, non-sealed type (transformer tank body and cover are bolted), copper wound, primary winding in delta and secondary winding in star (vector symbol- dyn11), onan cooled transformer, conforming to is 1180 (part 1):2014 with amendment nos. 1,2,3,4 or latest, and supplied with all standard fittings mentioned in clause 20.1 of is 1180 (part 1) latest withcondition that drain-cum-sampling valve will be applicable for all capacity of transformers. oil temperature indicator & winding temperature indicators will be provided as per clause 20.2 f) of is 1180 (part 1). terminal arrangement: the transformers shall be fitted on high voltage and low voltage sides with outdoor type bushings of appropriate voltage and current ratings. the high voltage bushings (3 nos.) shall conform to is/iec 60137. the low voltage bushings (4 nos.) shall conform to is 7421. suitable cable-endbox along with cable entry hole glands is to be provided at l.t. side. following has to be submitted by supplier along with supply of material: (i) type test report of transformer having same rating, make (& model if any) and design from nabl accredited lab as per is: 1180 (part 1) latest. (ii) routine test certificates as per is: 1180 (part 1) latest. (iii) special test certificates as per clause 21.4 sl. no. (a), (c), (d) & (e) of is: 1180 (part 1) latest. detailed specification attached as annexure a. [ warranty period: 30 months after the date of delivery ]]