Tender For supply of chemicals and plasticwares c c - measuring scoop white pp 10 ml , sterile individually packed long handle sampling spoon hips 5ml 5.6 inch overall long , sterile individually packed long handle sampling spoon hips 15ml 5.1inch overall long , nitrile gloves powder free small , nitrile gloves powder free medium , nitrile gloves powder free large , kimwipes disposable wipes 11.17 cm x 21.3 cm , gloves dispenser 3 places , hand protector grip silicone , ultra clean tube conical bottom pp with hdpe closure 15ml pp hdpe conforming to usp class vi autoclavable , self standing centrifuge tube pp hdpe conforming to usp class vi autoclavable 50 ml free of detectable pyrogen rnase dnase , conical centrifuge tube rack rpp wells for 15 ml tubes 50 ml tubes , float rack pp 16 places , rack for micro tube pc 24 places 15 ml capacity , micro tube rack reenforced nylon 96 places , 96 place reversible rack with cover pp 1.5 or 2 ml tubes in one side the reverse side holds 05 ml tubes , combi lock rack pp holds four 50 ml tubes twelve 1.5 ml tubes thirtytwo 1.5 ml micro tubes or thirtytwo 0.5 ml micro tubes , test tube stand rpp non autoclavable 20 places , drying rack with drain hole 30 pegs , utility tray pp 540 mm l x 435 mm w x 130 mm h , utility tray pp 320 mm l x 260 mm w x 100 mm h , cryo cube box pp 100 places 1.8 ml capacity 140 mm l x 140 mm w x 55 mm h , pcr mini cooler pp with insulating solution 96 places , ice bucket with lid pur 4.5 l capacity 335 mm l x 285 mm w x 187 mm h , parafilm m 2inch w x 250inch l , parafilm dispenser , cryo tags 38 mm l x 19 mm b , gel caster for submarine electrophoresis unit , gel scoop acrylic 14 cm x 20 cm , edta disodium salt 99 percent ar , sodium chloride 99.5 percent ar , tris base 99.5 percent ar , tris hcl 99 percent ar , sodium acetate anhydrous 99 percent ar , trissaturated phenol 99.5 percent mol bio grade , phenol chloroform isoamyl alcohol 25 24 1 , chloroform isoamyl alcohol 24 1 mol bio grade , ethanol molecular grade , sds 99 percent ar , proteinasek 20mg ml , ammonium chloride 99.5 percent ar , potassium bicarbonate 99.7 percent ar , glacial acetic acid 99.7 percent ar , agarose h for electrophoresis
Tender For supply of srphc82278027-crt- p pulse generator for delivery of cardiacresynchronizationtherapy. system should include a current generation crt pulse generator compatible with bipolar steroid-eluting atrial and ventricular leads and a biploar left ventricular lead (coronary sinus ). should provide independently programmable right and left ventricular pulse outputs and interventricular delay ( with the choices of right ventricular alone, leftventricular alone or biventricular pacing as well as the choice of which ventricle is to bepaced first with optimization of delay for pacing of other ventricle ). should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrialtachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch, ventricular rate management etc., pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimal features for introduction, positioning and fixation and documented low displacement rates. safety and efficacy of the system should be well documented. unit: number. ]
Tender For supply of srphc82278027-crt- p pulse generator for delivery of cardiacresynchronizationtherapy. system should include a current generation crt pulse generator compatible with bipolar steroid-eluting atrial and ventricular leads and a biploar left ventricular lead (coronary sinus ). should provide independently programmable right and left ventricular pulse outputs and interventricular delay ( with the choices of right ventricular alone, leftventricular alone or biventricular pacing as well as the choice of which ventricle is to bepaced first with optimization of delay for pacing of other ventricle ). should have features like negative av hysteresis and triggered modes for continuous delivery of crt. should have advanced features for detection and management and prevention of atrialtachycardias and atrial fibrillation as well as detailed data storage of all arrhythmias and therapy as well as trends over time. should have features for management of atrial fibrillation including mode switch, ventricular rate management etc., pulse generator should be suitable for use with either an endocardial lv lead or an epimyocardial lead for lv stimulation. lv leads should have optimal features for introduction, positioning and fixation and documented low displacement rates. safety and efficacy of the system should be well documented. unit: number. ]